  • Page 1

    Owner's operating manual uninterruptible power system for models: ed1000rm-1 ed2000rm-1 ed2400rm-1 ed2500rm-1 falcon ® electric inc. Irwindale, ca 91706 tel. 626-962-7770 fax. 626 962-7720 t he information contained herein is the property of falcon ® electric inc., is proprietary, confidential, and ...

  • Page 2

    Table of contents important safety instructions (read first) . . 1 chapter 1, ed series ups overview . . . . 2 model cross reference table . . . . 2 block diagram . . . . . . 3 selection guide . . . . . . 4 chapter 2, installation . . . . . . 5 inspecting the equipment . . . . 5 ups setup . . . . . ...

  • Page 3: Save These Instructions

    Important safety instructions save these instructions this manual contains important instructions which must be followed during the installation, operation and maintenance of this ups and it’s batteries. Please read all instructions before operating this equipment and save this manual for future ref...

  • Page 4

    Chapter chapter 1 1 ed series ups - overview congratulations! You have selected the highest quality protection for your computer today. The falcon ® ed series ups offers a quiet and compact package with superior performance you can depend on. You now own a member of the ed family which is a proud pa...

  • Page 5

    Refer to the simplified block diagram, figure 1, for a system description. The ac source is rectified and provides energy for the dc + choppers and a float charge to a standby battery. These dc choppers then supply the power to operate the dc/ac inverter. During a utility power-loss, the ac rectific...

  • Page 6

    U n it n am e ed 1000r m -1 ed 2000r m -1 ed 2400r m -1 ed 2500r m -1 n om inal va 1000 2000 2400 2500 c urrent-input 10.4a 19a 24a 25a c urrent-o utput r m s n on-linear (r epetitive peak) 8.3a 20a 16.7a 38a 20.0a 45.6a 20.9a 47.6a input line plug l5-15p l5-30p o utput d istribution c onnectors 3 (...

  • Page 7

    Chapter chapter 2 2 installation inspecting the equipment if any falcon ® equipment has been damaged during shipment, keep the shipping cartons and packing materials for the carrier and file a claim for shipping damage. If you discover damage after acceptance, file a claim for concealed damage. To f...

  • Page 8

    Chapter chapter 3 3 controls, displays & functions 1. Input power circuit breaker & indicator pull button to remove input power. The ups will go into battery mode when pulled. Push the button in to reset the circuit breaker. 2. Ups output circuit breaker & infdicator this circuit breaker provides ov...

  • Page 9

    Typical ups rear panel layout 9. Db-9f contact closure interface this connector gives access to the ups contact closure status interface. Please reference page 8 of this manual for details. 10. Inlet for input line cord on ed1000-1 only. Line cord permenently attached to ed1500-1 and ed2000-1. 11. C...

  • Page 10

    Chapter chapter 4 4 db-9 communications interface 8.

  • Page 11

    Chapter chapter 5 5 operation the falcon ® ed unit is very simple to use. 1. Verify the power cord is plugged into the correct voltage power source. 2. Activate the power switch to the "on" position. 3. The green ac led illuminates. 4. The green inv led illuminates. 5. Leave the power switch "on" an...

  • Page 12

    To escape this condition, the problem must first be corrected then turn the ups power switch "off", then back "on". It is recommended that you leave the ed unit power switch "on" at all times and switch your devices "off" individually. This will insure that your batteries are always at a maximum cha...

  • Page 13

    Chapter chapter 6 6 maintenance & technical support 1. Care & maintenance falcon ® ed series upss are designed to be maintenance-free. They can be cleaned with a damp cloth or non-abrasive cleanser, providing the ups is turned off and the input plug is disconnected from the utility source. On a regu...

  • Page 14

    The following precautions should be observed by a qualified technician when working with batteries. 1. Remove watches, rings, or other metal objects. 2. Use tools with insulated handles. 3. Wear rubber gloves and boots. 4. Do not lay tools or metal parts on top of batteries 4. Storing the ups and ba...

  • Page 15

    6. Technical support your falcon ® electric ed series ups is backed by one of the finest customer service teams assembled. Write, call, fax or email should you require technical assistance or service. Falcon electric, inc. Irwindale, ca. 91706 voice 626.962.7770 fax 626.962.7720 service 800.842.6940...