Falcon SG800-2 SG1K-1T Owner's Operating Manual

Summary of SG800-2 SG1K-1T

  • Page 1

    Owner's operating manual sg series tm ups plus ® uninterruptible power supply models: sg800-1t, sg800-2t sg1k-1t, sg1k-2t, sg1.5k-1t & sg1.5k-2t sg2k-1t, sg2k-2t, sg2k-1tx & sg2k-2tx & sg2k-1txi & sg2k-2txi sg3k-1t, sg3k-2t, sg3k-1tx & sg3k-2tx & sg3k-1txi & sg3k-2txi detailed sg series product spec...

  • Page 2

    Sg ups features. . . . . . . 1 sg series on-line ups block diagram. . . . . 1 important safety instructions (read first) . . . . 2 chapter 1. Sg series ups overview . . . . . 3 true regenerative on-line design . . . . 3 input power factor correction . . . . 3 microprocessor control . . . . . 3 snmp/...

  • Page 3

    Sg series ups features sg series on-line ups system block diagram true double conversion on-line design input power factor correction wide input voltage window pure sinewave output precision output voltage regulation superior brownout, surge and transient protection internal system bypass eliminates...

  • Page 4: Save These Instructions

    Important safety instructions save these instructions this manual contains important instructions which must be followed during the installation, operation and maintenance of this ups and its batteries. Please read all instructions before operating this equipment and save this manual for future refe...

  • Page 5

    Chapter 1 chapter 1 sg series ups - overview true regenerative on-line design as new and innovative technologies have become the backbone of today's businesses, maximum system availability is critical and downtime is more expensive than ever. Increasingly, businesses need a ups that not only protect...

  • Page 6

    Chapter 2 chapter 2 installation instructions 1. Verify the following is included in the ups shipping carton: (1) ups, (1) software diskette(s) & manual, (1) power cord (800va-1kva models only), (1) owners manual & (1) ups/computer cable. 2. Verify the ups unit is configured for the proper input/out...

  • Page 7

    5. For sg800va - sg1kva and 208-240v models, connect the power cord to the ups inlet located on the ups rear panel. On sg1.5k - sg3k 120v models the line cord is permanently attached to the ups. 6. Select a suitable location for the ups, near enough to the computer or equipment to to be protected. C...

  • Page 8

    Switch settings for -1 models switch settings for -2 models green mode switch settings for all models view of dip switches located on the ups rear panel 6.

  • Page 9

    Typical extended battery bank & ups interconnection (mini-tower models shown; same applies for floor standing banks) installation procedure for extended battery banks 1. Remove the battery fuse located on the ups rear panel. See illustration above. 2. Locate the battery interconnect cable(s). 3. Con...

  • Page 10

    Sg800va-3kva tower extended battery bank selection guide for 800va-1kva models for 1.5kva-2kva models for 3kva models 8 note: the backup times stated are for reference only. Backup time may vary due to the type of load, battery age or condition, environmental conditions, etc..

  • Page 11

    9 chapter 3 chapter 3 operation ups front panel indicator and function keys 1. Load level indicator leds *the first or bottom led is lit when the output load is greater than 25% of the rated output of the ups. *the second led is lit when the output load is greater than 50% of the rated output of the...

  • Page 12

    5. Bypass indicator led when this led is lit the ups bypass is active. Should the alarm led be lit at the same time, the ups detected an internal failure and the ups must be serviced. 6. Inverter indicator led when this led is lit, the ups inverter is operating and powering the connected load. 7. Gr...

  • Page 13

    Audible alarms audible alarm signals are divided into two different levels of alarm status. Category one alarms represent normal or correctable operational alarms. Category two alarms are sounded in the event of abnormal operation. 1. Category one alarms: a. Two short beeps followed by three short b...

  • Page 14

    Sg800-1t & sg1k-1t typical rear panel overview sg800-2t & sg1k-2t typical rear panel overview 12 chapter 4 chapter 4 rear panel details please verify the ups output rat- ings match your requirement cover plate for optional communications interface baord cover plate for optional communications interf...

  • Page 15

    Sg1.5k-1t, sg2k-1t & sg3k-1t typical rear panel overview 13 sg1.5k-2t, sg2k-2t & sg3k-2t typical rear panel overview output receptacles shown with (1) l6-20r & (2) 6-20t receptacles cooling fans do not block output receptacles (6) nema 5-15r standard battery fuse battery fuse.

  • Page 16

    14 sg2k-1tx, sg2k-2tx, sg2k-1txi, sg2k-2txi, sg3k-1tx, sg3k-2tx, sg3k-1txi & sg3k-2txi typical rear panel overview sg2k-1txi, sg2k-2txi & sg3k-1txi, sg3k-2txi output configuration the sg -2txi models provide three galvanically isolated 240vac and 120vac outputs. The two 120vac receptacles are an iso...

  • Page 17

    Chapter 5 chapter 5 communications interfaces rs-232 interface 15 location: the rs-232 interface is standard on all sg series ups models. The port is located on the ups rear panel, via a db-9 female connector. Supported protocols: upsilon 2000 & sec smart mon baud rate ------- 2400bps data length---...

  • Page 18

    16 dry contact & opto coupler interface board options typical falcon dry contact relay board pin & jumper assignment for the falcon ua88374 relay option board (no on-bypass signal) pin & jumper assignment for the falcon ua88376 relay option board (with on-bypass signal).

  • Page 19

    17 pin assignment for the falcon ua88373 opto-coupler option board (no-bypass signal) typical falcon opto-coupler interface card opto board internal circuitry.

  • Page 20

    Apc style dry contact relay board pin & jumper assignment for the falcon ua88377 relay option board (apc style board) 18.

  • Page 21

    Chapter 6 chapter 6 maintenance & technical support 1. Care & maintenance falcon ® sg series upss are designed to be maintenance-free. They can be cleaned with a damp cloth or non-abrasive cleanser, providing the ups is turned off and the input plug is disconnected from the utility source. On a regu...

  • Page 22

    The following precautions should be observed by a qualified technician when working with batteries: 1. Remove watches, rings, or other metal objects. 2. Use tools with insulated handles. 3. Wear rubber gloves and boots. 4. Do not lay tools or metal parts on top of batteries. 4. Storing the ups and b...

  • Page 23

    6. Technical support your falcon ® electric sg series ups is backed by one of the finest customer service teams assembled. Write, call, fax or email should you require technical assistance or service. Falcon electric inc. 5106 azusa canyon road irwindale, ca. 91706 service 800.842.6940 voice 626.962...

  • Page 24

    Falcon electric, inc. New product limited warranty limited warranty: falcon warrants that this product will be free from defects in materials and workmanship for a period of two years from the date of shipment by falcon. Procedures: any defective product must be returned to falcon. No product can be...

  • Page 25: Sg Series

    Sg series tm ups plus ® 800va to 1.5kva 23.

  • Page 26: Sg Series

    Sg series tm ups plus ® -1tx & -1txi 2kva - 3kva 24.

  • Page 27: Sg Series

    Sg series tm ups plus ® 2kva & 3kva 25.