Falcon SUP1.0K-1C User Manual - Save These Instructions

Summary of SUP1.0K-1C

  • Page 1

    Falcon ® electric, inc. Sup series tm user’s guide 700-1000va www.Falconups.Com 800.842.6940 sup700-1c, sup1.0k-1c falcon® electric, inc. Irwindale, ca 91706 tel. 626-962-7770 fax. 626 962-7720 om48031-sup, 01/09/04, rev a. 5116 azusa canyon road.

  • Page 2: Table Of Contents

    Table of contents 1 important safety instructions (read first) . . 2 chapter 1. Sup ups overview . . . . 3 chapter 2. Installation . . . . . . 4 inspecting the equipment . . . . 4 ups setup . . . . . . . 4 communications interface . . . . 5 chapter 3. Controls, displays & functions. . . 6 front pane...

  • Page 3: Save These Instructions

    Important safety instructions save these instructions this manual contains important instructions which must be followed during the installation, operation and maintenance of this ups and its batteries. Please read all instructions before operating this equipment and save this manual for future refe...

  • Page 4

    Chapter 1 chapter 1 falcon ® smp series - overview the falcon ® sup series ups has the unique ability to operate from either 120vac domestic or 230vac international utility power, while providing 120vac domestic output power. The sup does not perform frequency conversion, however it is the ideal sol...

  • Page 5

    Chapter 2 chapter 2 installation inspecting the equipment if any falcon ® equipment has been damaged during shipment, keep the shipping cartons and packing materials for the carrier and file a claim for shipping damage. If you discover damage after acceptance, file a claim for concealed damage. To f...

  • Page 6

    Communications interface the ups provides both a contact closure and a true rs-232 computer interface. The definition and setup for rs-232 is as follows: baud rate : 2400 bps data length : 8 bits stop bit : 1 bit parity : none pin #6 : rs-232 data tx out pin #7 : common for pin #6 and pin #9 pin #9 ...

  • Page 7

    Chapter 3 chapter 3 controls, displays & functions a b c front panel a. Main control button - this button is used to turn the ups on and off, to perform a ups self test, or to reset and silence an audible alarm. Refer to page 10 for operation instructions. B. A liquid crystal display (lcd) is provid...

  • Page 8

    Lcd symbol descriptions 1. Over load --the connected load exceeds the ups output rating. Remove some of the load from the ups to correct this condition. 2. Load level --bar graph indicates the percent of ups load capacity remaining. 3. Ups is loaded - this symbol is displayed when the ups output loa...

  • Page 9

    6 boost mode - the avr is increasing the ups output voltage due to a low utility voltage condition or "brown-out". The sinewave symbol is also displayed to indicate that the ups is operating normally from the utility line. 7. Timer is enabled - this symbol will be displayed during the following cond...

  • Page 10

    15. Lcd metering display - when the ups is turned on, this portion of the lcd display indicates the ac output voltage initially. Depressing the downward scroll button will indicate the following each time it is depressed: mode value display description ac output voltage ac output voltage ac input vo...

  • Page 11

    2. Input fuse - always replace with the same fuse type and rating. 3. Inlet - for connection of incoming power cord. 4. Ups output receptacles - the top nema type receptacles will be found on all domestic (120v) models. Iec type receptacles will be found on international (230v) models. 5. Db-9 rs-23...

  • Page 12

    Chapter 4 chapter 4 operation 1. Turning the ups on and off depending on how the ups was turned off, it may automatically turn on when the input plug is plugged in. If it does not turn on automatically, depress the control button located on the front panel for four seconds until the ups turns on. To...

  • Page 13

    6. Battery charging this ups is shipped from the factory with its batteries fully charged. However, some charge may be lost due to the self discharge characteristics of the internal sealed lead-acid battery. Always allow the ups to recharge for 24 hours prior to use. To recharge, simply connect the ...

  • Page 14

    1. Care & maintenance falcon ® sup series upss are designed to be maintenance free. They can be cleaned with a damp cloth or non-abrasive cleanser, providing the ups is turned off and the input plug is disconnected from the utility source. On a regular basis, check the vents to make sure they are ke...

  • Page 15

    The following precautions should be observed by a qualified technician when working with batteries: 1. Remove watches, rings, or other metal objects. 2. Use tools with insulated handles. 3. Wear rubber gloves and boots. 4. Do not lay tools or metal parts on top of batteries 4. Storing the ups and ba...

  • Page 16

    6. Technical support your falcon ® electric sup series ups is backed by one of the finest customer service teams assembled. Write, call, fax or email should you require technical assistance or service. Falcon electric, inc. Irwindale, ca. 91706 voice 626.962.7770 fax 626.962.7720 service 800.842.694...

  • Page 17

    1. Time and scope of warranty: 1.1 falcon ® hereby warrants parts shipped under this agreement to be free from defective workmanship for a period of one year following date of shipment. Accidental damage, misuse or normal wear and tear shall not be construed as a defect. 1.2 the date of shipment as ...

  • Page 18: Sup Series™ Ups

    Sup series™ ups 700va & 1kva model number sup700-1c sup1.0k-1c nominal va 700 1000 electrical input nominal ac voltage 120v or 230v 120v or 230v current-amps 7 (120v), 3.6 (230v) 10 (120v), 5.2 ( 230v) ac voltage window -21% to 25% frequency 50/60 hz (auto – tracking) frequency range 47 – 63hz ups i...