FältCom ECII Flex User Manual

Summary of ECII Flex

  • Page 1

    Version: 3.2.4-b updated: 2014-08-28 fältcom ecii ™ flex manual.

  • Page 2

    162187 manual fältcom ecii™ flex page 2 of 40

  • Page 3: Table Of Contents

    Table of contents 1 notes ...............................................................................................................................5 2 copyright ......................................................................................................................5 3 declaration...

  • Page 4

    Alarm input setting .................................................................................................. 17 test of alarm reception........................................................................................... 19 change of time delay for alarm button .........................

  • Page 5: Notes

    1 notes we would like to thank you for placing your confidence in fält communications ab (fältcom) and we are convinced that the choice of one of our security products will fulfil your expectations. In order to operate this fältcom ecii™ flex correctly we would ask you to read this manual carefully ...

  • Page 6: Product Description

    4 product description the fältcom ecii™ flex is an alarm equipment for the pstn network with built in duplex speech communication designed for installation in lifts. When a lift passenger presses the button for alarm/emergency signal, the ecii™ flex automat- ically calls up an alarm centre or some o...

  • Page 7

    Ming mode. The led’s can be programmed to display other light sequences, see section pro- gramming for more information. The ecii™ flex can be mounted behind the car operating panel (cop), on the panel with a small front plate and frame or with a larger front plate and frame with an integrated alarm...

  • Page 8

    The others will listen in on the line and only pick up the line if that particular lift phone number is chosen. Connect the lift phones in parallel and place the lift phone with number 1 at the far end of the line. View section 6.13 for programming. Installation of two or more fältcom ecii™ flex on ...

  • Page 9: Installation Instructions

    4.4.3 remote programming mobile the ecii™ flex can be programmed by using an app provided by fältcom free of charge for android or iphone. For android, go to google play shop and search for “flex android”, download and install. For iphone, start the browser and enter the address: www.Faltcom.Se/flex...

  • Page 10

    2. Fasten the frame first and then the lift phone with the enclosed screws. Note! Make sure the cables have been connected and the lift phone has been programmed. Mounting behind the car operating panel this alternative is only possible if there is already a prepared space for a lift phone behind th...

  • Page 11

    Connection to telephone line the lift phone must be connected to a standard analogue telephone line. Normally it can also be connected to an isdn connection via a terminal adaptor. To minimize disturbance when more than one ecii™ flex is connected to the same telephone line it is recommended that th...

  • Page 12

    Check carefully that the cable will not be torn off, squeezed or chafed between the lift car and shaft wall. 5.4.3 flat cable type 1. Check that the cable is long enough, allow- ing a margin, to reach the telephone jack. 2. Fasten the cable securely until it reaches the lift shaft wall. 3. Secure th...

  • Page 13

    Measure to verify the correct voltage between the pins. 2. Connect the cable to the dc converter input. 3. Connect the dc converter to the lift phone outlet marked ”dc”. 4. Connect the dc converter on the outside of the lift and fasten the cable with cable ties or cable clips. Connection to loop amp...

  • Page 14: Programming

    6 programming programming of alarm numbers, alarm codes and various functions can be affected by using the keypad on the reverse of the ecii™ flex, by calling the unit using a standard telephone or by using suitable windows-based software. This section describes programming using the key- pad and st...

  • Page 15

    Lapse of 30 sec. Programming mode is automatically deactivated. Important! The telephone number of alarm receiver 1 must be programmed to make an alarm. Alarm code 1 is default ‘1’ but must be programmed if the alarm is sent to an alarm central. Activation of programming mode 6.2.1 first time used i...

  • Page 16

    Clear all active alarms this function will clear all active alarms on the ecii™ flex. It will not remove receivers or codes, but it will make the ecii™ flex stop calling out an alarm, without an acknowledgment of that alarm. Any new alarm input made after this will be handled normally. From keypad: ...

  • Page 17

    Alarm is activated and the led’s on the front will flash alternately three times. 6.6.1 dedicated receiver for input 2 and input 3 the alarm inputs 2 and 3 can be configured to have a dedicated receiver. If the input 2 or 3 is programmed as an emergency alarm the ecii flex will call the first attemp...

  • Page 18

    Examples of technical alarms are sum alarms from the lift controller or sensors from the lift car doors and more. Note: if the alarm input is connected to the lift controller or other external devices the connection must be separated using a relay connection. Setting of alarm input 1 by default the ...

  • Page 19

    Alarm input 1 as follows: if alarm input 2 is configured as x = 0 => n/o and y = 2 => filtering signal it will not be possible to initiate an alarm from alarm input 1 as long as an open signal is obtained in alarm input 2. The push button in alarm input 1 is filtered. When the signal in alarm input ...

  • Page 20

    1. Alarm receiver 1 2. Alarm receiver 2 3. Sequence receiver 3 4. Sequence receiver 4 5. Sequence receiver 5 6. Sequence receiver 6 7. Test alarm/routine call receiver 8. Technical alarm receiver 9. Information alarm receiver change of time delay for alarm button the delay time on the alarm button c...

  • Page 21

    It is also possible to make the ecii™ flex call out an additional test alarm/routine call after each main alarm. To do this, use alternative 1b instead of 1a. Activation of test alarm/routine call 1 a. Select the required test interval: 1 to 30 days. (use a number between 1 and 30.) from keypad: fro...

  • Page 22

    From phone:  301  # 4. To verify the test alarm/routine call function: from keypad: from phone:  300 # please view section 6.9 for priority order on test of receiver. To delete the test alarm/routine call receiver, test alarm/routine call interval and test alarm/routine call code: from keypad: fr...

  • Page 23

    From keypad: from phone:  140  # with two or more ecii™ flex connected on the same telephone line, one of them is pro- grammed as the master with number ‘1’. The others are coded with their individual number (2- 9) by replacing the digit with the corresponding digit. Example: from keypad: for lift...

  • Page 24

    From phone: # 141 # the active alarm mode is automatically disconnected after 6 hours, but will be extended with 6 hours if a new speech connecting alarm is made or if a call is made to the ecii™ flex dur- ing this interval. Answering time for incoming calls the number of ringing signals before the ...

  • Page 25

    From keypad: from phone: # 330 # 6.14.2 battery alarm from a gsm gateway (art. 202236) similar to 6.15.1 above the gsm gateway (art. 202236) has battery back-up power in case of power failure in the building. When a battery alarm is generated in the gsm gateway, it will signal this to the ecii™ flex...

  • Page 26

    From phone:  321 # return to default acknowledgment: from keypad: from phone: # 321 # note: if a speech message is used; press any key to stop the message. Acknowledge on end – 323 when the ecii™ flex calls out an alarm duplex conversation is automatically connected. But if there is no answer and n...

  • Page 27

    The function is disconnected and return to default setting is made with: from keypad: from phone: # 710 # led flashing sequence when the alarm button has been activated and an alarm is registered by the ecii™ flex, the left led on the ecii™ flex is lit up in yellow. When the alarm is acknowledged th...

  • Page 28

    To reset the alarm type to the default value, enter: from keypad: from phone: # 600 # programmable alarm type alarm input 2 same functionality as for alarm input 1. Changed by: from keypad: xx> from phone:  601  # to reset the alarm type to the default value, enter: from keypad: from phone: # 601 ...

  • Page 29

    For test of the alarm receiver program: from keypad: from phone:  800 # note: if the main alarm was never acknowledged, no info alarm will be sent out. Also, this function will not dial out an info alarm following battery alarms nor test alarms/routine calls or end-of-alarm. End-of-alarm to ensure ...

  • Page 30

    From keypad: from phone:  610 # 6.22.1 end-of-alarm receiver end-of-alarms can be sent to a separate alarm receiver different from alarm receiver 1. If no specific alarm receiver is programmed for end-of-alarm the alarms are sent to alarm receiver 1. From keypad: from phone:  640 # and to set a sp...

  • Page 31

    To specify a cpc receiver: from keypad: from phone:  061  # receiver: 1 alarm receiver 1 2 alarm receiver 2 3 sequence receiver 3 4 sequence receiver 4 5 sequence receiver 5 6 sequence receiver 6 7 test alarm/routine call receiver 8 technical alarm receiver 9 information alarm receiver dial tone d...

  • Page 32

    From phone:  410 # deleting message 1: from keypad: from phone: # 410 # note: resetting to default setting (p 990p) will not clear the speech messages. Speech message 2; for the alarm receiver this message is played in the receiving telephone before the alarm call has been acknowledged by the alar...

  • Page 33: Alarm Reception

    7 alarm reception all tone dialling telephones (units with the keys  and #) can work as simple alarm receivers. The telephone keypad is used to control alarm reception and to acknowledge the alarm un- less the need for acknowledgment has been deactivated. The most important key to learn is 4, used ...

  • Page 34

    The alarm is disconnected by pressing , end (320, 321, 323). No more calls will be made. Repeat message 2 if the receiver wants to hear the recorded message 2 once again press 1, repeat message 2. The message can be repeated at any time during the call. Forwarding a call if you want to forward the ...

  • Page 35

    Conversation on incoming calls. End the call by hanging up or press  on the receiver handset. Volume control adjust the volume in the ecii™ flex speaker by using a screw driver to turn the volume control. The control is located on one of the sides of the ecii™ flex. - to increase the volume; turn t...

  • Page 36: Product Label

    8 product label following is a description of the ecii™ flex product label. Liftphone flex unit part no 202187 snr mccccc w yyww www.Faltcom.Se rev z.Z sw a.D.C the product label describes: part no 202187: product part number (order number) snr mccccc: serial number of the product. Rev z.Z: hardware...

  • Page 37: 10  Updates

    Fält communications ab reserves the right to determine if the product will be repaired or re- placed. Warranty ceases to be valid if defects occur due to incorrect use, or other method of application, or context than specified in this manual. Ecii™ flex should only be used in the context for which i...

  • Page 38

    Service form 162187 manual fältcom ecii™ flex page 38 of 40

  • Page 39: 12  Technical Data

    12 technical data supply voltage: telephone line (single mounted) if line voltage is higher than 25 vdc no external power is needed. If line voltage is between 25 vdc and 20 vdc an external power supply is required. Supply voltage: 4.5 vdc, 1500v isolation dc converter. (2-9 units on the same line) ...

  • Page 40: 13  Contact Information

    13 contact information fält communications ab vasagatan 23 se-903 29 umeÅ, sweden support: + 46 (0)90 18 39 27 e-mail: support.Liftphones@faltcom.Se phone: + 46 (0)90 18 39 00 (exchange) fax: + 46 (0)90 18 39 29 homepage: http://www.Faltcom.Se service address: fält communications ab c/o bl elektroni...