LOCATIONS TO AVOID FOR SMOKE ALARMS, Continued
•
In very dusty, dirty, or greasy areas. Do not install a Smoke Alarm
directly over the stove or range. Keep laundry room Smoke Alarms free
of dust or lint.
•
Near fresh air vents, ceiling fans, or in very drafty areas. Drafts can
blow smoke away from the unit, preventing it from reaching the sensing
chamber.
•
In insect infested areas. Insects can clog openings to the sensing
chamber and cause unwanted alarms.
•
Less than 12 inches (305mm) away from fluorescent lights. Electrical
“noise” can interfere with the sensor.
•
In “dead air” spaces. “Dead air” spaces may prevent smoke from
reaching the Smoke Alarm.
Avoiding Dead Air Spaces
“Dead air” spaces may prevent smoke from reaching the Smoke Alarm.
To avoid dead air spaces, follow the installation recommendations below.
On ceilings, install Smoke Alarms as close to the center of the ceiling as
possible. If this is not possible, install the Smoke Alarm at least 4 inches
(102 mm) from the wall or corner.
For wall mounting (if allowed by building codes), the top edge of Smoke
Alarms should be placed between 4 inches (102 mm) and 12 inches (305
mm) from the wall/ceiling line, below typical “dead air” spaces.
On a peaked, gabled, or cathedral ceiling, install the first Smoke Alarm
within 3 feet (0.9 meters) of the peak of the ceiling, measured horizontally.
Additional Smoke Alarms may be required depending on the length, angle,
etc. of the ceiling's slope. Refer to NFPA 72 for details on requirements for
sloped or peaked ceilings.
4
ABOUT SMOKE ALARMS
Battery (DC) operated Smoke Alarms: Provide protection even when
electricity fails, provided the batteries are fresh and correctly installed.
Units are easy to install, and do not require professional installation.
AC powered Smoke Alarms: Can be interconnected so if one unit senses
smoke, all units alarm. They do not operate if electricity fails.
AC with battery (DC) back-up: will operate if electricity fails, provided the
batteries are fresh and correctly installed. AC and AC/DC units must be
installed by a qualified electrician.
Smoke Alarms for Solar or Wind Energy users and battery backup
power systems:
AC powered Smoke Alarms should only be operated
with true or pure sine wave inverters. Operating this Smoke Alarm with
most battery-powered UPS (uninterruptible power supply) products or
square wave or “quasi sine wave” inverters will damage the Alarm.
If you are not sure about your inverter or UPS type, please consult with
the manufacturer to verify.
Smoke Alarms for the hearing impaired: Special purpose Smoke Alarms
should be installed for the hearing impaired. They include a visual alarm
and an audible alarm horn, and meet the requirements of the Americans
With Disabilities Act. Can be interconnected so if one unit senses smoke,
all units alarm.
Smoke alarms are not to be used with detector guards unless the
combination has been evaluated and found suitable for that purpose.
All these Smoke Alarms are designed to provide early warning of fires if
located, installed and cared for as described in the user’s manual, and if
smoke reaches them. If you are unsure which type of Smoke Alarm to
install, refer to Chapter 2 of the National Fire Protection Association (NFPA)
Standard 72 (National Fire Alarm Code) and NFPA 101 (Life Safety Code).
National Fire Protection Association, One Batterymarch Park, Quincy, MA
02269-9101. Local building codes may also require specific units in new
construction or in different areas of the home.
SPECIAL COMPLIANCE CONSIDERATIONS, Continued
2. Multi-Family or Mixed Occupant Residence: Apartment building, con-
dominium. This Smoke Alarm is suitable for use in individual apartments or
condos, provided a primary fire detection system already exists to meet fire
detection requirements in common areas like lobbies, hallways, or porches.
Using this Smoke Alarm in common areas may not provide sufficient warn-
ing to all residents or meet local fire protection ordinances/regulations.
3. Institutions: Hospitals, day care facilities, long-term health care facilities.
This Smoke Alarm is suitable for use in individual patient sleeping/resident
rooms, provided a primary fire detection system already exists to meet fire
detection requirements in common areas like lobbies, hallways, or porches.
Using this Smoke Alarm in common areas may not provide sufficient warn-
ing to all residents or meet local fire protection ordinances/regulations.
4. Hotels and Motels: Also boarding houses and dormitories. This Smoke
Alarm is suitable for use inside individual sleeping/resident rooms, provided
a primary fire detection system already exists to meet fire detection
requirements in common areas like lobbies, hallways, or porches. Using
this Smoke Alarm in common areas may not provide sufficient warning to
all residents or meet local fire protection ordinances/regulations.
LIMITATIONS OF SMOKE ALARMS
Smoke Alarms have played a key role in reducing deaths resulting from
home fires worldwide. However, like any warning device, Smoke Alarms can
only work if they are properly located, installed, and maintained, and if
smoke reaches them. They are not foolproof.
Smoke alarms may not waken all individuals. Practice the escape plan
at least twice a year, making sure that everyone is involved – from kids to
grandparents. Allow children to master fire escape planning and practice
before holding a fire drill at night when they are sleeping. If children or
others do not readily waken to the sound of the Smoke Alarm, or if there
are infants or family members with mobility limitations, make sure that
someone is assigned to assist them in fire drill and in the event of an
emergency. It is recommended that you hold a fire drill while family
members are sleeping in order to determine their response to the sound
of the Smoke Alarm while sleeping and to determine whether they may
need assistance in the event of an emergency.
Smoke Alarms cannot work without power. Battery operated units can-
not work if the batteries are missing, disconnected or dead, if the wrong
type of batteries are used, or if the batteries are not installed correctly. AC
units cannot work if the AC power is cut off for any reason (open fuse or
circuit breaker, failure along a power line or at a power station, electrical
fire that burns the electrical wires, etc.). If you are concerned about the
limitations of battery or AC power, install both types of units.
Smoke Alarms cannot detect fires if the smoke does not reach the
Alarms. Smoke from fires in chimneys or walls, on roofs, or on the other
side of closed doors may not reach the sensing chamber and set off the
alarm. That is why one unit should be installed inside each bedroom or
sleeping area—especially if bedroom or sleeping area doors are closed
at night—and in the hallway between them.
Smoke Alarms may not detect fire on another floor or area of the
dwelling. For example, a stand-alone unit on the second floor may not
detect smoke from a basement fire until the fire spreads. This may not give
you enough time to escape safely. That is why recommended minimum
protection is at least one unit in every sleeping area, and every bedroom on
every level of your dwelling. Even with a unit on every floor, stand-alone units
may not provide as much protection as interconnected units, especially if
the fire starts in a remote area. Some safety experts recommend installing
interconnected AC powered units with battery back-up (see “About Smoke
Alarms”) or professional fire detection systems, so if one unit senses smoke,
all units alarm. Interconnected units may provide earlier warning than stand-
alone units since all units alarm when one detects smoke.
Smoke Alarms may not be heard. Though the alarm horn in this unit
meets or exceeds current standards, it may not be heard if: 1) the unit is
located outside a closed or partially closed door, 2) residents recently con-
sumed alcohol or drugs, 3) the alarm is drowned out by noise from stereo,
TV, traffic, air conditioner or other appliances, 4) residents are hearing
impaired or sound sleepers. Special purpose units, like those with visual
and audible alarms, should be installed for hearing impaired residents.
Smoke Alarms may not have time to alarm before the fire itself
causes damage, injury, or death, since smoke from some fires may
not reach the unit immediately. Examples of this include persons
smoking in bed, children playing with matches, or fires caused by
violent explosions resulting from escaping gas.
Smoke Alarms are not foolproof.
Like any electronic device, Smoke
Alarms are made of components that can wear out or fail at any time.
You must test the unit weekly to ensure your continued protection. Smoke
Alarms cannot prevent or extinguish fires. They are not a substitute for
property or life insurance.
Smoke Alarms have a limited life. The unit should be replaced immedi-
ately if it is not operating properly. You should always replace a Smoke
Alarm after 10 years from date of purchase. Write the purchase date on
the space provided on back of unit.
SPECIAL COMPLIANCE CONSIDERATIONS
This Smoke Alarm alone is not a suitable substitute for complete fire detec-
tion systems in places housing many people—like apartment buildings,
condominiums, hotels, motels, dormitories, hospitals, long-term health care
facilities, nursing homes, day care facilities, or group homes of any kind—
even if they were once single-family homes. It is not a suitable substitute
for complete fire detection systems in warehouses, industrial facilities,
commercial buildings, and special-purpose non-residential buildings which
require special fire detection and alarm systems. Depending on the building
codes in your area, this Smoke Alarm may be used to provide additional
protection in these facilities.
The following information applies to all four building types below:
In new construction, most building codes require the use of AC or AC/DC
powered Smoke Alarms only. In existing construction, AC, AC/DC, or DC
powered Smoke Alarms can be used as specified by local building codes.
Refer to NFPA 72 (National Fire Alarm Code) and NFPA 101 (Life Safety Code),
local building codes, or consult your Fire Department for detailed fire
protection requirements in buildings not defined as “households.”
1. Single-Family Residence: Single family home, townhouse. It is recom-
mended Smoke Alarms be installed on every level of the home, in every
bedroom, and in each bedroom hallway.