  • Page 1

    Owner’s manual read and save these instructions model no. Fp4520** the involution ™ ceiling fan net weight 9.07 kg (20 lbs).

  • Page 2

    1. Limited lifetime motor warranty - if any part of your fan motor fails, due to a defect in materials or workmanship during the lifetime of the original purchaser, fanimation will provide the replacement part free of charge, when the defective fan is returned to our national service center. Proof o...

  • Page 3

    This manual is designed to make it as easy as possible for you to assemble, install, operate, and maintain your ceiling fan unpacking instructions for your convenience, check-off each step. As each step is completed, place a check mark. This will ensure that all steps have been completed and will be...

  • Page 4

    4 your new ceiling fan will require a grounded electrical supply line of 120 volts ac, 60 hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs. Figure 1 depicts different structural configurations that may be used for mounting the outlet ...

  • Page 5

    How to assemble your ceiling fan pin setscrew hanger ball figure 1 1. Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod. (figure 1) remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstal...

  • Page 6

    6 how to hang your ceiling fan figure 1 floor ceiling no less than 7 ft ▲warning the fan must be hung with at least 7´ of clearance from floor to blades (figure 1) ▲warning the outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs. Hanger bracket must seat fi rml...

  • Page 7

    Wh-t o mot or blk-t o mot or blu-t o light to hot blk to fan grn to ground blk grn wh blk 120 vac supply (user supplied) grn from hanger ball grn from bracket 7 how to wire your ceiling fan - cw40 wall control if you feel that you do not have enough electrical wiring knowledge or experience, have yo...

  • Page 8

    8 assembling and mounting the floating rings or nameplate floating rings installation: 1. Carefully slide the two floating rings into the slot with the upward motion to avoid scratching the finish on the fan housing. (figure 1) 2. Securely fasten the two floating rings with two screws and lock washe...

  • Page 9

    9 mounting the fan blades and switch cup assembly blade assembly: 1. Carefully slide the blade through the slot as shown. (figure 1) 2. Securely fasten the two blades with washer-head screws with fiber washers. Do not over-tighten. (figure 2) housing switch cup/adapter assembly: 3. Assemble the swit...

  • Page 10

    10 figure 5 figure 6 5. Assemble the switch cup assembly onto the assembled adapter with three screws. (figure 5) note: the reverse switch is located on the switch cup assembly. (figure 5) 6. Assemble the lower cover onto the assembled switch cup adapter by twisting in the clockwise direction. Don’t...

  • Page 11

    11 maintenance periodic cleaning of your new ceiling fan is the only maintenance that is needed. When cleaning, use only a soft brush or lint free cloth to avoid scratching the fi nish. Abrasive cleaning agents are not required and should be avoided to prevent damage to fi nish. Caution do not use w...

  • Page 12

    Before discarding packaging materials, be certain all parts have been removed parts list model fp4520** ref. # description part # 1 hanger bracket assembly with screws ap255bl 2 downrod/hanger ball assembly containing: adr1-6** 2a hanger ball assembly 2b downrod 2c clevis pin 2d hairpin clip 3 ceili...

  • Page 13

    13 6 5 the involution ™ model fp4520** exploded-view 1 3 4 2a 2b 2c 2d 2 note: the illustration shown is not to scale or its actual confi guration may vary. Product/parts are subject to change without notice. Figure 1 7 11 10 9 8 12 13.

  • Page 14

    14 trouble shooting ▲warning for your own safety turn off power at fuse box or circuit breaker before trouble shooting your fan. Trouble probable cause suggested remedy 1. Fan will not start 1. Fuse or circuit breaker blown. 2. Loose power line connections to the fan, or loose switch wire connection...

  • Page 16

    Copyright 2008 fanimation 2008/01 10983 bennett parkway zionsville, in 46077 (888) 567-2055 fax (866) 482-5215 outside u.S. Call (317) 733-4113 visit our website @ www.Fanimation.Com.