Fanimation Tropicana FP1620 Owner's Manual

Manual is about: Fanimation Tropicana FP1620 Ceiling Fans: Owners Manual

Summary of Tropicana FP1620

  • Page 1

    Owner's manual read and save these instructions model no. Fp1620 the tropicana ® ceiling fan net weight 22 lbs. Fp1620no = natural wicker with rust trim & narrow oval blades suitable for use in damp locations.

  • Page 2

    1. Limited lifetime motor warranty - if any part of your fan motor fails, due to a defect in materials or workmanship during the lifetime of the original purchaser, fanimation will provide the replacement part free of charge, when the defective fan is returned to our national service center. Proof o...

  • Page 3

    3 downrod/ hanger ball motor coupling cover note: place the parts from the loose parts bag in a small container to keep them from being lost. If any parts are missing, contact your local retailer. Wiring outlet box and box connectors must be of type required by local code. The minimum wire would be ...

  • Page 4

    Downrod/hanger ball assembly clevis pin note: the setscrews must be properly installed as described above, or fan-wobble could result. 8. The fan comes with blue, black, and white leads. Before installing fan, measure up approximately 6-9 inches above top of downrod/hanger ball assembly. Cut off exc...

  • Page 5

    5 how to hang your ceiling fan the fan must be hung with at least 7' of clearance from floor to blades (figure 4) warning figure 4 no less than 7 ft ceiling floor 1. Place the rubber pads on the ceiling side of the hanger bracket (figure 5). 2. Securely attach the hanger bracket to the outlet box us...

  • Page 6

    6 to reduce the risk of fire, electrical shock, or personal injury, mount fan to outlet box marked acceptable for fan support, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consul...

  • Page 7

    7 3. Secure the ceiling canopy to the hanger bracket with screws provided (screws shipped already threaded into hanger bracket) (figure 8). Your fan is now wired to be turned on and off from the fan pull chain speed control. Warning to avoid possible electrical shock, be sure electricity is turned o...

  • Page 8

    Heat or humidity. • hi push button – high fan speed • med push button – medium fan speed • low push button – low fan speed • off push button – fan off • light push button – no function (unless light kit is installed) 8 how to wire your fan - c4 hand-held remote (optional) figure 10a figure 10b 9v ba...

  • Page 9

    Off 1 2 3 9 how to wire your ceiling fan - c1 wall control (optional) figure 14 figure 16 figure 15 note: if fan or supply wires are different colors than indicated, have this unit installed by a qualified electrician. Wh- to mot or grn from bracket grn from hanger ball blk-t o mot or to fan to hot ...

  • Page 10

    Periodic cleaning of your new ceiling fan is the only maintenance that is needed. When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish. Abrasive cleaning agents are not required and should be avoided to prevent damage to finish. Maintenance blade cleaning warning do...

  • Page 11

    11 warning for your own safety turn off power at fuse box or circuit breaker before trouble shooting your fan. 1. Blades not attached to fan. 2. Loose screws in motor housing. 3. Screws securing fan blade holders to motor flywheel are loose. 4. Wire connectors inside housing rattling. 5. Motor noise...

  • Page 12

    12 19 motor coupling cover narrow oval - white (5) mccmc ceiling canopy screws (2) 4 clevis pin 8 11 10 12 13 14 15 18 switch housing (with wicker cover) blades reverse switch speed control pull chain fan motor (with wicker cover) assembly consisting of: flywheel downrod support bridge pin 9 fp1600,...

  • Page 13

    13 9 16 15 13 22 21 20 14 12 18 10 8 17 6 7 4 5 19 3 2 1 1a the tropicana ® fp1600/1610/1620 exploded-view figure 18 note: the illustration shown is not to scale or its actual configuration may vary, the wicker is removed for parts clarity ground wire (green) 11 ground wire (green).

  • Page 14

    10983 bennett parkway zionsville, in 46077 (888) 567-2055 fax (866) 482-5215 visit our website @ fanimation.Com 2003/11 copyright 2003 fanimation.