Fantech HEPA DM 3000 Installation, Operation And Maintenance Manual - page 4
4
O P E R AT I O N
Your Fantech HEPA filtration system incorporates three stages of filtration. Air is drawn from the house via one of the installa-
tion examples, found in this manual, by a powerful efficient EBM fan.The air is cleaned as it passes through the filters, where it
is then reintroduced back into the home, cleaned of the majority of harmful particles.
Note: A semi-annual service schedule must be followed to ensure the HEPA unit is operating at its full potential.
I N S TA L L AT I O N
DM 3000 - Duct Mounted model
Option A
Option B
The return side of the furnace is the recommend-
ed location for the HEPA to connect to.The supply
side is normally avoided due to the higher static
pressure.
* Furnace fan should operate continuous or when
HEPA unit is on and running. (Options A & B)
* Diagrams are examples only. Actual installation may vary.
Airflow
Airflow
1. Using mounting plate, mark holes on
furnace return duct to be cut.
2. Cut holes in desired location and
attach mounting plate to duct with
screws.
DM 3000 - (installation examples)
3. Attach HEPA unit to mounting plate
with screws.