Fantech Hood Liners Installation And Operation Manual - page 4
7
6
fantech
fantech
Use & Care
Operation controls
1. Always activate the ventilator whenever using cooking appliances.
2. Activate the ventilator a few minutes before starting to cook to estab-
lish an airflow pattern within the room.
3. Adjust the fan speed according to the amount of cooking exhaust.
4. Adjust the dimmable halogen lights as desired.
5. Eliminate air currents in the hood vicinity by shutting nearby windows
and doors, turning off ceiling fans and closing the adjacent heating and
air conditioning outlets.
6. Place your largest pans, skillets and stock pots on the rear burners
whenever possible.
DO NOT operate the vent system without the filters in place,
or with dirty, grease laden filters.
Energy saving tips
1. Do not operate the blower at a speed that is higher than necessary to
remove the cooking exhaust. Running at excessive speeds removes
more air from the inside of the house that must be replaced by out-
side air. This may be especially costly when your home’s heating or air
conditioning system is in operation. Turn off the unit once the smoke
and cooking odors have been eliminated.
2. Clean filters and grease laden surfaces often to improve efficiency.
3. Always use lids on cookware to retain heat and moisture.
4. Minimize the amount of liquid used to cook food.
5. Select cookware of proper size, material and construction for the
cooking task being performed.
Care & Cleaning
1. Proper cleaning is necessary to maintain performance and appear-
ance, while also ensuring safe operation. The frequency of cleaning
should be adjusted according to the type and amount of cooking. Best
results will be achieved by cleaning soiled components as soon as pos-
sible.
2. Filters must be cleaned regularly.
Remove one filter at a time, grasp the filter handle and gently pull
toward you, then down and back. Filter should be installed with the
handle in the rear filter slot.
3. The filters may be cleaned by hand washing in hot water using a mild
detergent solution, or by placing them in the top rack of an automatic
dishwasher. Dry the filters completely before using again.
4. Stainless steel surfaces should be cleaned with a solution of mild
detergent and warm water. Rinse and dry with a soft lint-free cloth.
CAUTION: Do not use any type of pad that will scratch the liner
5.
CAUTION: If a commercially available stainless steel cleaner is used. It
is important to read the labels for chlorine compounds. Chlorine is a
corrosive substance. If these compounds are present, rinse thoroughly
and dry with a soft lint-free cloth. Follow polish manufacturer’s instruc-
tions.
6. Always wipe stainless steel surfaces with the grain. Never wipe
across the grain.
7. After cleaning, reinstall the filters carefully.
Replacing light bulb
It is recommended that replacement bulbs with characteristics matching
those of the original bulbs are used. The original bulbs furnished with the
HL Series hood liners are:
- 50 Watt, type MR16 halogen lamp with a GU10 base
Choosing the Right Remote Mount Blower
Fan location
Fan model
Air Flow Rate (cfm)
at 0.0” Ps
Hood Liner Model Application Air Flow Rate* (cfm)
Duct Size** (in)
HL 30
HL 36
HL 42
HL 48
Remote Interior
FG 6
303
8
275
275
-
-
FG 6XL
483
8
381
381
381
-
FG 8
461
8
359
359
359
-
FG 8XL
502
8
427
427
427
427
FG 10
513
10
-
494
494
494
FG 10XL
589
10
-
570
570
570
FG 12XL
940
12
-
-
-
806
Remote Interior
FKD 8XL
836
8
-
440
440
440
FKD 10
910
10
-
-
772
772
FKD 10XL
1266
10
-
-
973
973
FKD 12XL
2016
12
-
-
-
1384
Remote Exterior
Roof or Wall
RE/REC 6
227
6
180
-
-
-
RE/REC 8XL
409
8
355
355
355
RE/REC 10XL
753
10
-
-
715
715
RE/REC 10XLT
1008
10
-
-
-
883
Remote Exterior Wall
RVF 6
242
6
172
172
-
-
RVF 6XL
381
8
338
338
338
-
RVF 8XL
435
8
321
321
321
321
RVF 10
790
10
-
-
646
646
RVF 10L
1060
10
-
-
-
842
RVF 10XL
1245
10
-
-
-
880
* Hood liner model application air flow rates estimated for system with 20 feet of duct, two 90 deg. elbows, a backdraft damper, roof cap and hood filters.
** Duct size is recommended for the fan’s air flow rate. Size transitions may be necessary for duct connection to hood liner and fan. Other duct-mounted accessories, such as backdraft damp-
ers, silencers, and roof caps, are recommended to be same size as duct diameter..