FAR PEAK6 Owner's Manual

Manual is about: active two way monitor

Summary of PEAK6

  • Page 1

    Fundamental acoustic research owners manual peak6 (v) 1 owner’s manual active monitor peak6 (v).

  • Page 2: Peak6 (V)

    Fundamental acoustic research owners manual peak6 (v) 2 thank you for choosing the far peak6 (v) active two way monitor. In order to obtain the best performance from this active monitor, please be sure to read this owner’s manual and use your speaker only in accordance with its instruction. Contens ...

  • Page 3

    Fundamental acoustic research owners manual peak6 (v) 3 thank you for choosing a far active monitor. This unit is an exceptional product that will give you years of superb performance. Do not open the cabinet. Do not attempt to service this unit. Tampering with internal components can cause fire or ...

  • Page 4: Peak6 (V)

    Fundamental acoustic research owners manual peak6 (v) 4 technical description peak6 (v) sensitivity db spl maximum pressure level (2 cabinets @ 1 m) 114 frequency range hz ± 3 db 50-22000 low pass section crossover frequency 3500 hz 24 db/octave high pass section crossover frequency 3500 hz 6 db/oct...

  • Page 5

    Fundamental acoustic research owners manual peak6 (v) 5 listening position cm 50-120 amplifier specifications power (peak) w power 150 power (nominal) w power @ 4 ohm 100

  • Page 6

    Fundamental acoustic research owners manual peak6 (v) 6 characteristics power bandwidth 20 - 25000 hz slew rate 35 v/µs sn ratio > 100 db distortion intermodulation 0,01% total 0,05% input sensitivity 0 db impedance > 10 kohm connectors input (symmetric) xlr & jack link xlr remote rj-45 external dim...

  • Page 7

    Fundamental acoustic research owners manual peak6 (v) 7 technical drawing legend 1. Main level tuning 2. Limitor function 3. Link 4. Input xlr 5. Mains 6. Power 7. Serial number 8. Rcv connection.

  • Page 8

    Fundamental acoustic research owners manual peak6 (v) 8 limitor function the peak6 (v) has a built in limitor developed to protect the drivers against harmful signals. The limitor acts directly on the input signal by decreasing it when it reaches the clipping level. To activate the limitor turn it t...

  • Page 9

    Fundamental acoustic research owners manual peak6 (v) 9.

  • Page 10

    Fundamental acoustic research owners manual peak6 (v) 10 troubleshooting this section is designed to trouble free technical operation. Most of the problems encountered by the users are due to operating mistakes .Please check this list first for a possible solution. If the problem persists, consult y...

  • Page 11

    Fundamental acoustic research owners manual peak6 (v) 11 optional remote control rcv innovation remains our most important consideration. We have created a remote for distance volume control : the rc–v. In conjunction with the dedicated card the remote will permit you to set the volume within 7 posi...