Faro DROPPY User Manual

Summary of DROPPY

  • Page 1

    Droppy dichiarazione di conformita’ 1 il fabbricante faro s.P.A. The manufacturer via faro, 15 20060 ornago (milano) italy dichiara sotto la propria responsabilità, che il prodotto: declares under its own responsability that the product: designazione del prodotto: distillatore product’s designation:...

  • Page 2

    Droppy 2 2 pericolo indice simbologie italiano......................................................................................................Pag. 1 inglese........................................................................................................Pag. 10 indice lingue i paragrafi ...

  • Page 3

    Droppy seguire tutte le indicazioni riportate nel presente manuale questo distillatore è consigliato per l’uso esclusivamente con l’erogazione di ac- qua potabile. Non tentare di depurare e rendere sicura acqua proveniente da fonti non potabili (non da bere). Non usarlo per altri scopi che non siano...

  • Page 4

    Droppy 4 norme di sicurezza scollegare il cavo elettrico del distillatore dalla presa murale per la pulizia del gruppo di base. Non immergere nell’acqua alcuna parte del distillatore. Per la pulizia della parte esterna del distillatore, utilizzare uno straccio inumidito. Risciac- quare la camera di ...

  • Page 5

    Droppy caratteristiche 5 distillatore d’acqua - elimina la scomodità e il costo dell‘acquisto di acqua in bottiglie. - prolunga la vita degli apparecchi che utilizzano acqua quali le sterilizzatrici faro - utilizzabile negli studi di dentisti e medici, chirurgia veterinaria, laboratori. Come funzion...

  • Page 6

    Droppy 6 caraffa con copertura base pulsante reset descrizioni delle parti istruzioni d’uso spegnimento del depuratore in fase operativa 1) togliere il bollitore 2) staccare la spina del cavo dalla presa. Prima di utilizzare il distillatore per la prima volta sebbene la pulizia del bollitore e della...

  • Page 7

    Droppy 7 7) il filtro al carbonio é confezionato separatamente in una busta di plastica. To- gliere il coperchio dalla sede del filtro al carbonio posto all’interno del coperchio della caraffa. Togliere il filtro al carbonio dalla propria busta e posizionarlo nell’ap- posito alloggiamento. Rimettere...

  • Page 8

    Droppy 8 8 8) per versare acqua dalla caraffa, aprire il tubo di scarico: tirare con il pollice la striscia centrale, posta sul coperchio della caraffa, nel senso della freccia. 9) depositare la caraffa piena di acqua distillata in frigorifero fino al momento in cui ce ne sarà bisogno. 10) quando il...

  • Page 9

    Droppy 9 guida ai problemi non produce alcuna acqua distillata 1. Il cavo del depuratore non é inserito nella presa di corrente elettrica. 2. Manca la corrente alla presa. 3. Il bollitore non è inserito nella presa. 4. Non è stato premuto il pulsante di ripristino o di inizio ciclo. 5. Il bollitore ...

  • Page 10

    Droppy 10 table of contents safety rules.................................................................................. Pag.11-12 features........................................................................................ Pag.13 description of parts..............................................

  • Page 11

    Droppy 11 safety rules observe all the instructions set forth in this manual. This purifier is recommended for use on potable water supplies only. Do not attempt to purify and makesafe drinking water from non-potable (not for drinking) water sources. Do not use for anything other than purifying wate...

  • Page 12

    Droppy 12 12 do not immerse any part of the purifier in water. To clean the outside of the purifier, wipe with a damp cloth. Rinse boiling chamber after every use. Use distiller cleaner or a dishes detergent only on the inside of the boiling chamber, when needed then rinse. Do not plug steam vent on...

  • Page 13

    Droppy 13 features water purifier - eliminates the inconvenience and expense of buying bottled water. - increases the life of water using appliances such as faro autoclaves - can be used in dental or doctors offices, veterinary surgeries and laboratories. How your purifier works - the purifier disti...

  • Page 14

    Droppy 14 14 description of parts stopping unit during operation 1. Remove kettle. 2. Unplug unit from outlet. Before using water from your water purifier for the first time although care is taken so your purifier, kettle and carafe are clean, some harmless substances may remain from manufacturing, ...

  • Page 15

    Droppy 15 8. Important: before using the carbon filter rinse the filter under purified water for 30 seconds, so that it is wet on all surfaces. If the filter ever dries out as a result of not using the purifier, remove it and rinse it to re-wet it down. 9. Place the carafe on the base unit, and plug...

  • Page 16

    Droppy 16 16 maintenance care and cleaning of your water purifier kettle after each use, rinse the inside with lukewarm tap water and remove any residue. Clean by wiping out the inside of the kettle with a damp cloth and rinse. If a deposit starts to form at the bottom, use water purifier cleaner. R...

  • Page 17

    Droppy 17 troubleshooting not making any purified water 1. Purifier power cord not plugged into electrical outlet. 2. No power to electrical outlet 3. Kettle not plugged into base receptacle. 4. Did not press reset or start button to start cycle. 5. Did not fill the kettle with tap water. Not making...

  • Page 18

    Droppy certificato di garanzia guarantee certificate droppy.

  • Page 19

    Droppy la faro concede al cliente finale una garanzia di 12 mesi, dalla data della fattura di acquisto. La riparazione in garanzia dovrà essere effettuata presso la faro o presso un riparatore autorizzato faro; spese e rischi di trasporto sono a carico dell’acquirente. Il certificato di garanzia, è ...

  • Page 20: Manuale D’Uso

    Manuale d’uso instruction manual manuale d’uso droppy.

  • Page 21

    Ed. 01/03 rev. 0 cod. 988209 internet: http://www.Faro.It faro s.P.A. Via faro, 15 20060 ornago (mi) italia tel. : 039 / 6878.1 (r.A.) fax : 039 / 6010540