Faroudja LD100 Installation & Operation Instructions

Manual is about: Line Doubler

Summary of LD100

  • Page 1

    The faroudja ld100/ld100u line doubler installation & operation instructions.

  • Page 2

    History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 licensees and awards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 system description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Page 3

    History faroudja laboratories, located in northern califor- nia’s silicon valley, was founded in 1971 by yves and isabell faroudja to develop state-of-the-art of video processing technology. Over the last 20 years, faroudja laboratories and its companion r&d center, faroudja research, have indeed de...

  • Page 4

    Licensees and awards 1987: smpte david sarnoff gold medal award for “contributing in optimizing ntsc performances” 1988: monitor award for “excellence in engineering ntsc encoders and decoders” 1989: bm/e award for “excellence in engineering” 1991: technology executive of the year from cable tv busi...

  • Page 5

    The faroudja system ld100 digital scan converter is a precision video instrument used to convert ntsc composite, y/c, or 525 line rgb or component interlaced signals into 525 line progres- sive outputs. Using the ld100 digital scan converter will produce pictures with more details, remove unwanted p...

  • Page 6

    Circuit description figure 1 is a block diagram of the ld100 showing signal flow and the location of front panel controls and switches. Composite video and y/c (s-vhs) inputs are connected to the units decoder with agc control and converted to y, r-y and b-y signals. The y, (luminance) output from t...

  • Page 7

    Ld100 technical highlights – the ld100 is far more than simply a “line doubler”. It is a truly unique product in the world of high performance video. The ld100 is actually a complex image processor that consists of three distinct components – all utilizing patented faroudja technologies and engineer...

  • Page 8

    7 on two different mechanisms. Horizontal resolution is a function of bandwidth (frequency response) of the circuitry while vertical resolution is a function of the scanning fre- quency (the number of scan lines in each picture). Given these mechanisms and the average size picture tube being 8-10”, ...

  • Page 9

    Unpacking remove the ld100/ld100u from the shipping container and examine it for any signs of shipping damage or missing items, (check inventory list on page 5). All shipping materials should be saved if the unit is to be moved or should need to be returned for service or repair. Installation the ld...

  • Page 10

    15. Sync termination switch – select on when 15. Not looping the composite sync signal to other video devices, (75 ohm). 16. Sync input loop (bnc) – composite sync input loop 17. Sync input (bnc) – composite sync input 18. Red output (bnc) – red output 714mv 19. Green output (bnc) – green output 714...

  • Page 11

    The ld100 control panel selecting a push button control lights the adjacent led to indicate activation or selection of that partic- ular function. 1) power on/off – press the button and the led lights green to indicate power on. When the ld100 powers up it is automatically set to oper- ate just as i...

  • Page 12

    6) brightness level – known as “set-up” in the broadcast industry, the brightness control is used to set up the background black level. Pull the knob out and turn fully counter clockwise until the picture goes dark. Then rotate the con- trol clockwise until the black areas in the picture just begin ...

  • Page 13

    Problem solution no power light unit not turned on unit not plugged in fuse blown no power at plug no picture video source not selected no video source connected or operating projector/monitor not turned on projector/monitor not connected correctly bad video cable unit in freeze mode check brightnes...

  • Page 14

    Overview remote control of the ld100 / ld100u line doubler is provided by an rs-232 serial interface connector located on the rear panel of the unit. A external controller such as a computer or integrated system controller with an rs-232 interface may be used to control all user accessible functions...

  • Page 15

    Command line the ld100 is programmed by means of a “command line”, which is an ascii string of up to 255 characters that contains one or more individual instructions to the ld100. The command line offers the best compromise between manual opera- tion via a data terminal and automatic control via a c...

  • Page 16

    St or st this command will return a string showing the current settings of the ld100. Example: help or help this command will return a list of commands used for the ld100 line doubler. Ld100 local / remote operation the ld100 stores all of it’s settings in a non-volatile ram and will return to the l...

  • Page 17

    Cable lengths and distribution amplifiers to aid in achieving the bet results from your installa- tion, we suggest the following minimum standards for cable runs when an ld100 is used. To preserve the video quality of the ld100, the signal path should be no more than –3db down at 25 mhz through a 75...

  • Page 18

    17 specifications ld100 specifications input signals (ntsc) 525 line 2:1 interlace video 1vp-p, negative sync 714mv luminance y/c y/c (3.58) non-composite 700m/vp-p y 286mvp-p c (burst) rgb 700mvp-p non-composite, 1vp-p composite component y(1v w/sync), r-y(714mv), b-y(714mv) composite sync negative...

  • Page 19

    Warranty information all faroudja laboratories products are warranted to the original purchase against defective materials and workmanship under normal use and service for a period of one (1) year from the date of shipment. This warranty shall be of no force and effects if mod- ifications have been ...