6.0 Enrollment
Transmitter must be clicked twice within a Receiver’s read range to be learned upon initial Receiver power up. This synchronizes the transmitter
and receiver rolling codes. If the transmitter is clicked more than five times outside of the Receivers read range the transmitter and receiver will be
desynchronized . To re-sync click twice again within read range.
7.0 Time-Out
Ranger transmitters make use of a time-out feature to preserve battery life and prevent interference with other transmitters on the field. When a button
is held down continuously the transmitter will transmit the code once and shutdown and will power up once the button is released.
8.0 Troubleshooting
Issue/Possible Cause
Corrective Action
No data received/Transmitter not enrolled
Transmitter must be clicked twice to be learned by the Receiver upon initial Receiver power up
Short Read Range/Receiver Knob
Adjust range adjustment control to maximum setting (turn clockwise)
Some Buttons not working/Channel Jumper
Jumper must be set to channel ‘A’ for buttons 1 & 2. Jumper must be set to channel ‘B’ for buttons 3 & 4
Prox insert not working/Compatibility
Proximity or contactless smartcard module interoperability must be requested on PO
Should any of the corrective actions mentioned above not improve performance, please contact Farpointe directly.
Many Farpointe Data Readers carry the following certifications:
FCC compliance Statement: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Product can be used without license conditions or restrictions in all European Union countries, including Austria, Belgium, Bulgaria, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Poland,
Portugal, Romania, Slovakia, Spain, Sweden, United Kingdom, as well as other non-EU countries, including Iceland, Norway, and Switzerland.
Farpointe Data reserves the right to change specifications without notice.
©2012 Farpointe Data, Inc. All rights reserved. Farpointe Data, the Farpointe Data logo, Pyramid Series Proximity, Pyramid Series logo, Ranger and
Delta are registered trademarks of Farpointe Data, Inc. Mifare is a registered trademark of NXP Semiconductors. AWID is a trademark of Applied
Wireless Identifications Group. HID and the HID logo are registered trademarks of HID Global Corporation, an ASSA ABLOY company. All other
trademarks are the property of their respective owners.
Farpointe Data Transmitters
Quick Start Guide
Ranger
®
Long-Range Wireless
Radio Transmitter (433-MHz)
232 Santa Ana Court
Sunnyvale, CA 94085 USA
Tel: +1-408-731-8700 Fax: +1-408-731-8705
e-mail: support@farpointedata.com
Web: www.farpointedata.com