Regulatory
Notices
EC Declaration of Conformity
FarSite Communications Limited declare that the product FarLinX X25 Gateway is in conformity with the
following standards and other documents:
Telecommunications Terminal Equipment: TTE Directive 91/263/EEC, TBR1, TBR2
Electromagnetic compatibility: EMC Directive 2004/108/EC, EN55022, EN55024, EN61000-3-2, EN61000-3-3
Safety: LVD Directive 2006/95/EC, IEC EN 60950
Federal Communications Commission (FCC) Statement
Radio Frequency Interference (RFI) (FCC 15.105)
The FarLinX X25 Gateway has been tested and found to comply with the limits for Class A digital devices pursuant to
Part 15 Subpart A of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
Labelling requirements (FCC 15.19)
This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference received, including interference
which may cause undesired operation.
Modifications
Changes or modifications to this equipment not expressly approved by FarSite may void the user’s authority to
operate this equipment.
FCC Declaration of Conformity
(In accordance with FCC dockets 96-208 and 95-19)
Manufacturer’s name: FarSite Communications Limited
Tempus Business Centre, 60 Kingsclere Road, Basingstoke
Hampshire, RG21 6XG, United Kingdom
FarSite Communications Limited declares that the product FarLinX X25 Gateway to which this declaration relates,
meet the requirements specified by the Federal Communications Commission as detailed in the following
specifications
Part 15, Subpart B, for Class A Equipment
FCC Docket 96-208 as it applies to Class A Personal Computers and Peripherals
The product has been tested at an external laboratory certified per FCC rules and has been found to meet the FCC,
Part 15, Class A emission limits. Documentation is on file and available from FarSite.
Industry Canada
This Class A digital apparatus meets the requirements of the Canadian Interference Causing Equipment regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le máteriel brouilleur du
Canada.
FarLinX X25 Gateway Quick Start Guide
N0901M-01 V2.3.3
www.farsite.com Page
1
FarLinX X25 Gateway
Q
UICK
S
TART
G
UIDE
Thank you for choosing the FarLinX X25 Gateway for your TCP to X.25 interworking needs. The FarLinX X25
Gateway is designed to enable X.25 network replacement while supporting legacy X.25 connected host and
terminal equipment without modification. It also permits XOT connected equipment access to X.25 connected
hosts.
Front Panel Guide
READY
indicates system status
Green
Red
Flashing Red
System OK
System not ready for use
System fault
LAN
indicates LAN status
Green
Flashing Green
Flashing RED
LAN interface operational
LAN data transfer activity
LAN not operating correctly (includes no LAN cable)
WAN
indicates WAN status
Green
Flashing Green
Red
Flashing Red
Amber
Configured X.25 interfaces operational
WAN data transfer activity
Some configured X.25 ports working correctly
No configured X.25 ports operating correctly (this would
include no cable attached)
No X.25 ports started (or none configured)