FBI XL-2T User Manual

Summary of XL-2T

  • Page 1

    ; ; / / 7 7 6hfxulw\6\vwhp 8vhu*xlgh n9819v2 11/98 arm stay instant ac/lb ready 1 2 3 4 5 6 fire burglary instruments, inc. Previous menu.

  • Page 2: Table of Contents

    - 2 - table of contents quick reference ............................................................................................................... 3 introduction ...................................................................................................................... 4 system refer...

  • Page 3: Quick Reference

    - 3 - quick reference to turn system on 1. Check to make sure the system is ready, the on/off (arm) light will light (green ready light is lit † ). 2. Enter your 4-digit user code. 3. Exit through a door designated by your installer as an exit/entry door. To turn system off 1. Enter through a door d...

  • Page 4: Introduction

    - 4 - introduction congratulations on your decision to protect your home or business with the xl-2t security system. You have chosen a reliable, state-of-the-art security system that is remarkably easy to operate. Your system has been professionally installed by your local security company whose rep...

  • Page 5: System Reference

    - 5 - system reference zone descriptions in the following table, enter a description of the area of protection for each zone. Example: zone 1 windows on north side of building zone 4 main entrance to building. Zone description 1 2 ___________________________________________ 3 4 5 6 7 entry time ____...

  • Page 6: System Reference

    - 6 - system reference (cont) user code assignments in the following table, enter the names of the individuals assigned to each specific user id. User id assigned to 1 (master user * ) 2 (master user * ) 3 4 5 6 7 8 9 10 11 12 13 door strike - yes no if no _____________ (if user 13 is not assigned t...

  • Page 7: Turning The System On

    - 7 - turning the system on is the system ready? You can turn the burglar portion of your security system on and off. Before you can turn the system on, it must be “ready.” if you have a protected door open, or someone is moving in view of a motion detector, the system will not display “ready.” the ...

  • Page 8: Turning The System On

    - 8 - turning the system on (cont) determine which zone or zones are not ready, resolve the problem, and turn the system on normally. If the problem cannot be resolved, you may bypass the zone that is not ready. Bypassing should only be done if the problem on the zone cannot be resolved, or if you i...

  • Page 9: Turning The System On

    - 9 - turning the system on (cont) to turn the system on in instant mode in instant mode, all alarm sensors including doors that normally have a delay to allow you to turn the system off will report an alarm immediately if activated. Check to make sure the system is ready. When it is ready, press: i...

  • Page 10: Turning The System Off

    - 10 - turning the system off when you turn the system off, you turn off only the burglar portion of your system; any smoke or heat detectors and panic keys will remain on. You must enter through a designated entry door and turn off the system within the time allowed. You can have different amounts ...

  • Page 11: User Codes

    - 11 - user codes to add or change a user code users can be added or changed directly at the keypad. Your system can have up to 15 different user codes. Users #1 and #2 are the only users allowed to add or delete other user codes. To add or change a user code, press the code button followed by user ...

  • Page 12: Miscellaneous Commands

    - 12 - miscellaneous commands send help alerts your system can be programmed for 3 separate keypad send help alerts that would send an emergency signal to your central station. See the system reference sheet to see which have been programmed for your system. Duress your system can be programmed to s...

  • Page 13: Miscellaneous Commands

    - 13 - miscellaneous commands (cont) turn chime on/off chime is an optional feature that causes the keypad to chime when selected doors are opened while the burglary protection is off or disarmed. Only your installer can program a zone for the chime feature, but once programmed, you can turn chime o...

  • Page 14: Testing The System

    - 14 - testing the system system test it is recommended that you test your system once a week using the following procedure: note: if your system is monitored, contact your central station before you perform this test. 1. Turn your security system on. 2. Wait until your exit time is over. Then activ...

  • Page 15

    - 15 - recommendations on smoke detectors with regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations contained in the national fire protection association’s (nfpa) standard #74 noted below. Early warning fire detection is best achieved by the installation of...

  • Page 16: Emergency Evacuation

    - 16 - emergency evacuation establish and regularly practice a plan of escape in the event of fire. The following steps are recommended by the national fire protection association: 1. Position your detector or your interior and/or exterior sounders so that they can be heard by all occupants. 2. Dete...

  • Page 17: Glossary

    - 17 - glossary ac indicator: small green power on-off light between the center buttons on the keypad. When lit, the system is running on primary power; when not lit, the system is running off the backup battery. Alarm: sound from keypad or other horn/siren indicates a burglar alarm, fire alarm, or ...

  • Page 18: Glossary

    - 18 - glossary (cont) exit delay: the period of time allowed between turning the system on and leaving through a designated exit/entry door before the system will register an alarm condition. This is determined at the time of installation. Interior zone: an interior zone is a group of points that p...

  • Page 19: Glossary

    - 19 - glossary (cont) silent condition: most types of alarms and troubles alert you with the keypad sounder and the sirens, horns, or speakers located in your premises. The intent is to advise you of the alarm or trouble and allow you to respond promptly. The audible sounds also let an intruder kno...

  • Page 20

    - 20 - federal communications commission (fcc) statement this equipment has been tested to fcc requirements and has been found acceptable for use. The fcc requires the following statement for your information: this equipment generates and uses radio frequency energy and if not installed and used pro...

  • Page 21

    - 21 - limitations of this alarm system while this system is an advanced design security system, it does not offer guaranteed protection against burglary, fire, or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of reaso...

  • Page 22

    - 22 - limitations of this alarm system (cont) alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers who are located on the other side of closed or partly open doors. If warning devices sound on a different level of the residence from the bedrooms, then they a...

  • Page 23: Limited Warranty

    - 23 - limited warranty fire burglary instruments, inc.,. A subsidiary of pittway corporation, and pittway corporation, its divisions, subsidiaries and affiliates ("seller"), 149 eileen way, syosset, new york 11791, warrants its security equipment (the "product") to be free from defects in material ...

  • Page 24

    ¬19^l n9819v2 11/98 fire burglary instruments, inc. Subsidiary of pittway corporation 149 eileen way, syosset, new york 11791 copyright © 1998 pittway corporation.