Fedders AC1A024A Installation, Operation And Maintenance Manual

Other manuals for AC1A024A: Specifications

Summary of AC1A024A

  • Page 1

    1 1 installation, operation and maintenance cased evaporator coils upflow/downflow recognize safety symbols, words and labels ................2 notes to installer ....................................................................2 introduction .........................................................

  • Page 2

    2 recognize safety symbols, words and labels what you need to know about safety instructions warning and important safety instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. Common sense, caution and care must be exercised when operatin...

  • Page 3

    3 introduction this manual is intended as an aid to qualified hvac installers during the installation of fedders cased coils on upflow or downflow furnaces. Do not install coil in horizontal position (see illustration below). Return return supply supply downflow furnace evaporator coil evaporator co...

  • Page 4

    4 3. Attach the bulb securely with the copper strap provided. 4. Insulate the bulb thoroughly with a suitable insulation material such as cork tape. 5. Coils with txvs should be charged 10-12 degrees (+ or – one degree) of sub-cooling. This supercedes any subcooling value listed with condensing unit...

  • Page 5

    5 model indoor cased coils 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 ac1a024a .10 .11 .12 .13 ac1a030a .15 .17 .19 .21 ac1a036a .19 .20 .22 .23 .24 ac1a042a .15 .17 .18 .21 ac1a060a .21 .23 .23 static pressure drop through dry coil* & housing (inches water column / cfm) check...

  • Page 6

    6 14 = 14.5” casing width 16 = 16” casing width 17 = 17.5” casing width 20 = 20.5” casing width 22 = 22” casing width c a = first revision major revision 024 = 18,000/24000 btu/h [5.28/7.03 kw] 030 = 30,000 btu/h [8.79 kw] 036 = 36,000 btu/h [10.55 kw] 042 = 42,000 btu/h [12.31 kw] 060 = 60,000 btu/...

  • Page 7

    7 this warranty does not cover damage caused by: • improper installation • misuse of equipment • negligent servicing • improper applications • preventative maintenance • unauthorized modifications • improper electrical supply • failure to follow manufacturer’s instructions and rating plate informati...

  • Page 8

    The information in this manual supersedes and replaces the previous instruction/operation manual with regards to air handler products. Illustrations cover the general appearance of the units at the time of publication and the manufacturer reserves the right to make changes in design and construction...