The following indoor coils and air handlers are designed and approved for use with the CH series units. Refer to the installation instructions
supplied with the indoor coils and air handler for installation detail. Some of the following information may not be included in those instructions
and is specific to the application of the CH series heat pump systems. If a different air handler is to be used with the matching indoor coil, refer
to the coil pressure-drop information for duct sizing requirements.
* Indoor pressure in inches based on dry coil. Increase pressure drop 25% for wet coil pressure drop.
All CH10 series outdoor units are shipped with pistons. Refer to Figure 1 on page 11 for proper installation.
* Indoor pressure based on dry coil. Increase pressure drop 25% for wet coil pressure drop.
All CH12 series units are to be matched with the air handler listed. These indoor units use a non-bleed-type expansion valve. Never use a
piston on the indoor coil when installing with a CH12 model unit. Refer to the instructions in Figure 2 on page 11 for installation of
expansion valve to indoor unit. TXV kits must be purchased as an accessory kit and are required to complete system installation.
10 FT.
15 FT.
25 FT.
CH1018B
A24B1
E3009A16
600
.12
5
/
16
5
/
8
5
/
16
5
/
8
3
/
8
3
/
4
CH1024B
A24B1
E3009A16
800
.20
5
/
16
5
/
8
5
/
16
5
/
8
3
/
8
3
/
4
CH1030B
A30B1
E3612A16
1000
.20
5
/
16
5
/
8
5
/
16
5
/
8
3
/
8
3
/
4
CH1036B
A36B1
E3618A16
1250
.24
5
/
16
3
/
4
3
/
8
3
/
4
3
/
8
7
/
8
CH1042C
A48B1
E6016A20
1350
.21
5
/
16
3
/
4
3
/
8
3
/
4
3
/
8
7
/
8
CH1048C
A48B2
E6026A20
1700
.30
3
/
8
7
/
8
3
/
8
7
/
8
3
/
8
7
/
8
CH1060C
A60B1
E6037A21
1850
.29
3
/
8
7
/
8
3
/
8
7
/
8
3
/
8
1
1
/
8
MINIMUM RECOMMENDED TUBE O.D.
LIQUID LINE SUCTION LINE
REQUIRED
CFM
CONDENSER
MODEL NO.
AIR HANDLER
MODEL NO.
COIL MODEL NO.
(Included with
Air Handler)
INDOOR COIL
PRESSURE
DROP*
10 FT.
15 FT.
25 FT.
CH1218B
A24B1
E3009A16
650
.11
5
/
16
5
/
8
5
/
16
5
/
8
3
/
8
3
/
4
CH1224B
A24B1
E3009A16
800
.15
5
/
16
5
/
8
5
/
16
5
/
8
3
/
8
3
/
4
CH1230B
A30B1
E3612A16
950
.15
5
/
16
5
/
8
5
/
16
5
/
8
3
/
8
3
/
4
CH1236B
A36B2
E3618A16
1200
.20
5
/
16
3
/
4
3
/
8
3
/
4
3
/
8
7
/
8
CH1242C
A42B1
E4824A20
1350
.26
5
/
16
3
/
4
3
/
8
3
/
4
3
/
8
7
/
8
CH1248C
A60B1
E6037A21
1450
.30
5
/
16
3
/
4
3
/
8
3
/
4
3
/
8
7
/
8
CH1260C
A60B1
E6037A21
1750
.25
3
/
8
7
/
8
3
/
8
7
/
8
3
/
8
1
1
/
8
MINIMUM RECOMMENDED TUBE O.D.
LIQUID LINE SUCTION LINE
REQUIRED
CFM
CONDENSER
MODEL NO.
AIR HANDLER
MODEL NO.
COIL MODEL NO.
(Included with
Air Handler)
INDOOR COIL
PRESSURE
DROP*
8
AIR HANDLER & EVAPORATOR MATCH-UPS