Fedders CH18ABD1VF Specification Sheet

Summary of CH18ABD1VF

  • Page 1

    Split system heat pump 1 1 ⁄ 2 thru 5 tons 208/230 volt, 1-phase, 60 hz performance: efficiency rating of 13 seer cooling capacities from 1 1 ⁄ 2 to 5 tons refrigerant circuit: factory installed biflow liquid line filter drier long life copper tubes, aluminum fins state-of-the-art compressors large,...

  • Page 2

    Product specifications 2 specifications subject to change without notice. Note: control circuit is 24v on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. 1. Wire size should be determ...

  • Page 3

    Product specifications 3 specifications subject to change without notice. Seer – seasonal energy efficiency ratio cop – coefficient of performance tdr – time – delay relay hspf – heating seasonal performance factor eer – energy efficiency ratio notes: 1. Tested combination per ari 210/240 standard. ...

  • Page 4

    Split system heat pump 4 specifications subject to change without notice. Line set length and size btuh suction line sizes liquid line sizes 15 ft. 25 ft. 50 ft. 75 ft. 15 ft. 25 ft. 50 ft. 75 ft. 18 3/4 3/4 3/4 3/4 3/8 3/8 3/8 3/8 24 3/4 3/4 3/4 3/4 3/8 3/8 3/8 3/8 30 3/4 7/8 7/8 7/8 3/8 3/8 3/8 3/...

  • Page 5

    Split system heat pump 5 specifications subject to change without notice. A ir in a ir in (f r o n t ) a ir d is c h a r g e a ir in c b f a ir d is c h a r g e f ie l d p o w e r s u p p ly c o n n e c t io n 1 1 /8 " h o l e f ie l d c o n t r o l s u p p ly c o n n e c t io n 1 /4 " h o l e l iq ...

  • Page 6: Ch 24 A B D 1 V F

    Fedders corporation 505 martinsville rd. Liberty corner, nj 07938 usa (908) 604-8686 form no. F-ch13 all product specifications reflect available information at the printing of this brochure. Fedders reserves the right to revise or modify products and/or specifications without notice. Copyright ©200...