    120 series loudspeaker, ismt loudspeaker, powered loudspeaker, and sounder 25 watts (model type es4 and es5) 2562192d rev. D 612 printed in u.S.A. Installation, operation, and maintenance.

  • Page 2

    2 federal signal corporation integrated systems 2645 federal signal drive university park, il 60484-3167, u.S.A. Warranty – seller warrants all goods for five years on parts and 2-1/2 years on labor, under the following conditions and exceptions: seller warrants that all goods of seller's manufactur...

  • Page 3: Contents

    3 contents safety message to installers, operators, and maintenance personnel .......................................................................5 an overview of the 120 series ............................................................6 product detail .............................................

  • Page 4: Tables

    4 120 series loudspeakers and sounder tables table 1 tone chart for 240 vac, 110 vac, and 24 vdc two-wire operation ...................................................... 16 table 2 tone chart for 24 vdc 3-to-5 wire and ac 4-to-6 wire operation ..........................................................

  • Page 5: Maintenance Personnel

    5 120 series loudspeakers and sounder safety message to installers, operators, and maintenance personnel it is important to follow all instructions shipped with this product. This device is to be installed by a trained electrician who is thoroughly familiar with local codes. The selection of the mou...

  • Page 6

    6 120 series loudspeakers and sounder an overview of the 120 series the federal signal 120 series loudspeaker complies with the atex directive for operation in gaseous hazardous areas classified as zone 1 with a temperature classification of –20 °c to +70 °c t4, –20 °c to +55 °c t5, and –20 °c to +4...

  • Page 7: Product Detail

    7 120 series loudspeakers and sounder product detail frequency range: explosion proof 350–4000 hz marine 300–3700 hz ambient temperature range: t4 explosion proof and marine –20 °c to +70 °c t5 explosion proof –20 °c to +55 °c t6 explosion proof –20 °c to +40 °c explosion proof rated: sound pressure...

  • Page 8: Aviso De Perigo

    8 120 series loudspeakers and sounder ce: emc to en 61000-6-1,2,3,4:2001 lvd to en 60065 ingress protection: explosion proof ip66 and ip67-en60529 marine ip66 and ip67-en60529 specifications: net weight exd model: 6.4 kg (14.1 lb) exde model: 6.5 kg (14.3 lb) shipping dimensions 32 cm x 30 cm x 38 c...

  • Page 9

    9 120 series loudspeakers and sounder shock hazard do not connect this unit to the system while the power is on. Failure to heed this warning could cause serious injury or death. Figure 1 loudspeaker dimensions 290a6311 2 mounting holes 7.0 mm (0.28 in) dia. 25.0mm (0.98 in) 315 mm (12.4 in) 229 mm ...

  • Page 10

    10 120 series loudspeakers and sounder check label details to ensure the unit is of the correct electrical rat- ing and hazardous area classification. For permanently connected equipment located in safe areas, the equipment supply should be provided via a disconnect device lo- cated in close proximi...

  • Page 11: Installing The Product

    11 120 series loudspeakers and sounder installing the product this product must be installed and maintained only by qualified per- sonnel who have received the relevant training. During installation ensure that all external screw threads and flameproof faces are suit- ably greased. Recommended torqu...

  • Page 12: Earthing

    12 120 series loudspeakers and sounder figure 3 side and rear views 290a6313 m20 gland entries (2) racheted bracket (2) m5 cap screw (4) end cap rear view side view figure 4 tapping transformer tappings std low terminals 1 and 2 25 w 20 w 15 w 10 w 5 w 2.0 w 1.5 w 1.0 w 0.6 w 0.2 w 1 and 3 3 and 4 2...

  • Page 13

    13 120 series loudspeakers and sounder figure 5 speaker wiring diagram wiring diagram 10-way terminal block inside sounder 1 2 3 4 5 6 7 8 9 10 +24 vdc / 48 vdc 0 v to next speaker audio signal audio signal 120 vac / 240 vac + − l n from echo model or previous speaker 2 x m20 gland entries internal ...

  • Page 14: For 240 Vac Operation

    14 120 series loudspeakers and sounder wiring the es4/ms4 multi-tone sounder this section provides instructions for operating the multi-tone sound- er at 240 vac, 110 vac, and 24 vdc. Also included are instructions for 24 vdc 2-wire operation, 24 vdc 3-to-5-wire operation, and ac 4-to-6-wire operati...

  • Page 15

    15 120 series loudspeakers and sounder figure 6 sounder wiring diagram 2 x m20 gland entries internal earth in lid external earth 290a6315 rear view live (in) neutral (out) (in) (out) (in) (out) (in) (out) t. 4 t. 3 t. 2 t. 1 common +24v f2 f1 tone selector detail of 12-connector terminal block figu...

  • Page 16

    16 120 series loudspeakers and sounder table 1 tone chart for 240 vac, 110 vac, and 24 vdc two-wire operation position tone 0 off 1 two tones: 588 hz for 0.25 second, 714 hz for 0.25 second 2 swept 600 hz > 700 hz in 0.5 second 3 telephone warble 4 constant 700 hz 5 simulated bell, three rings per s...

  • Page 17

    17 120 series loudspeakers and sounder for ac 4-to-6-wire operation see figures 6 and 7 on page 15 and the tone chart on page 18. 240 vac operation: 1. Set the voltage selector to 230 v. 2. Insert the 250 ma fuse, 3. Turn the tone selector to the 0 position. 4. Connect the live wire to the live in t...

  • Page 18: Routine Maintenance

    18 120 series loudspeakers and sounder table 2 tone chart for 24 vdc 3-to-5 wire and ac 4-to-6 wire operation terminal tone t1 two tones: 588 hz for 0.25 second, 714 hz for 0.25 second t2 swept 600 hz > 700 hz in 0.5 second t3 constant 700 hz t4 700 hz for 0.25 second, silence for 0.25 second routin...

  • Page 19: Ordering Replacement Parts

    19 120 series loudspeakers and sounder technical service and support for technical service and support, please contact: federal signal corporation integrated systems service department 2645 federal signal drive university park, il 60484-3167, u.S.A. Phone: +1 877 289 3246 fax: +1 708 534 4887 e-mail...

  • Page 20

    20 120 series loudspeakers and sounder.