Federal Signal Corporation 450E Installation And Maintenance Instructions Manual

Manual is about: Electronic Horn

Summary of 450E

  • Page 1

    25500096 rev. A3 0814 printed in u.S.A. Model 450e electronic horn installation and maintenance instructions français...............Page 15 español...............Página 29.

  • Page 2

    Industrial systems 2645 federal signal drive • university park, il 60484-3167 tel: 708-534-4756 • fax: 708-534-4852 email: elp@federalsignal.Com www.Federalsignal-indust.Com.

  • Page 3: Contents

    Model 450e electronic horn 3 contents safety message to installers and users ..........................................5 unpacking the horn ..........................................................................6 an overview of the model 450e .........................................................

  • Page 4

    4 installation and maintenance instructions model 450e electronic horn 1/2" (12.7 mm) typ. 3-3/8" (85.7 mm) typ. 3-5/8" (92.1 mm) typ. 1-13/16" (46 mm) typ. (4) 3/16" (4.8 mm) 1-11/16" (42.9 mm) typ. 45.0° typ. Outline of clearance hole for device © 2013 federal signal corporation. All rights reserv...

  • Page 5

    5 installation and maintenance instructions model 450e electronic horn safety message to installers and users people’s lives depend on your safe installation of our products. It is important to follow all instructions shipped with this product. This device is to be installed by a trained electrician...

  • Page 6: Unpacking The Horn

    6 installation and maintenance instructions model 450e electronic horn • any maintenance to the unit must be performed by a trained electrician in accordance with nec guidelines and local codes. • never alter the unit in any manner. • the nameplate should not be obscured, as it contains cautionary a...

  • Page 7

    7 installation and maintenance instructions model 450e electronic horn in addition to fire alarm system applications, the federal signal 450e horn is excellent for general alarm, start and dismissal, coded paging, and process control signaling in areas of high ambient noise levels. The model 450e ca...

  • Page 8: Wiring The Horn

    8 installation and maintenance instructions model 450e electronic horn wiring the horn shock hazard — to avoid electrical shock hazards, do not connect wires when power is applied. Failure to heed this warning may cause serious injury or death. Wiring precaution — an uninsulated section of a single ...

  • Page 9: Mounting The Horn

    9 installation and maintenance instructions model 450e electronic horn to wire the horn: 1. Connect the positive (+) lead from the power source to one of the positive terminals of the connector plug. 2. Connect the negative (-) lead from the power source to one of the negative terminals of the conne...

  • Page 10: Non-Weatherproof Mounting

    10 installation and maintenance instructions model 450e electronic horn there are three mounting options: non-weatherproof mounting, weatherproof mounting, and weatherproof panel mounting. Non-weatherproof mounting see figure 4. If weatherproof mounting is not required, mount the horn on a 4" x 4" o...

  • Page 11: Weatherproof Panel Mounting

    11 installation and maintenance instructions model 450e electronic horn figure 5 weatherproof mounting 290a7586 gasket #8-32 x 1-5/8" (4) backbox weatherproof panel mounting see figure 6 on page 12. For horn installations that require a watertight seal when mounted on panel, a flat rubber gasket is ...

  • Page 12

    12 installation and maintenance instructions model 450e electronic horn figure 6 weatherproof panel mounting 290a7588 #8-32 keps nuts (4) gasket panel #8-32 x 1-5/8" screw (4) getting repair service or technical assistance products returned for repair require a return authorization form from your lo...

  • Page 13

    13 installation and maintenance instructions model 450e electronic horn • the product is resalable and in the original cartons. • the product has not been previously installed. • the product is the current revision. • the product has not been previously repaired. • the product is a standard product....

  • Page 14