Fenix GR 300 Mounting And Operating Instructions - Electrical Installation
8
Electrical installation
The panel is fitted with a two-conductor cable for 1/N 230 V / 50 Hz with a plug for connection into a socket.
If the supply cord of the appliance is harmed, it must be replaced by producer or its service engineer or by similar qualified person to prevent
creation of a danger situation.
Panel control
With the help of the V22 thermostat and V26 receiver, for setting see the instruction manuals for the products.
The panel is also equipped with brake thermostat, which ensures that maximum temperature does not exceed 90°C.
Panel dismounting
Before loosening of mounting consoles, we disconnect the panel from the mains by means of double pole switch. With use of tools, please,
loosen mounting screws and lift the panel vertically upwards in such a way to loosen consoles out of screws. Next, it is necessary to discon-
nect the feeder cable from the box on the wall.
W A1
(mm)
B1
(mm)
C1
(mm)
D1
(mm)
300 460 220 465 220
500 660 220 565 220
700 800 220 565 250
900 800 220 765 300
W A2
(mm)
B2
(mm)
C2
(mm)
D2
(mm)
300 260 220 665 220
500 360 220 865 220
700 360 250 1035 220
900 560 300 1085 220