Fermax DT591 User Manual

Manual is about: 2 -Wire Intercom System

Summary of DT591

  • Page 1

    2 -wire intercom system dt591/592 user manual dt-eng-591/592-v1 160603 dt591 dt592.

  • Page 2

    Contents 1.Parts and functions............................................................................................. 1 2.Terminal descriptions .......................................................................................... 1 3.Specifications ...........................................

  • Page 3

    -1- 1.Parts and functions rainy cover camera lens night view led speaker nameplate call button microphone 3.54 in 6.93 in 0.91 in 2.Terminal descriptions bus pl s1+ s2+ s- 1 2 on 1 2 on mic adjustment lock control jumper doorstation code dip main connect port 1 2 3 spk adjustment note: dt592 has two...

  • Page 4

    -2- • lock control jumper: to select the lock type: see 5.2.1 , 5.2.2 • doorstation code dip: total 4 doorstations can be supported,see 6.1 • main connect port: to connect the bus line and the electronic locks. • bus: connect to the bus line, no polarity. • pl: external lock power input, connect to ...

  • Page 5

    -3- 4.2 mounting with rainy cover 63-65 in rainy cover the distance between the top of main unit and rain cover should be not less than 3mm. Rainy cover main unit ≥3mm main unit 1 2 1 2 3 4 1 2 on 4.3 placing name label move the plastic cover away to open the transparent name label cover, insert a n...

  • Page 6

    -4- 5.1 basic connection 5.System wiring and connections doorbell button switch - + 1 2 on l1 l2 pl s1+ s2+ s- + - dps dr-30-24 code=00, dip6=on 1 2 3 4 5 6 on dip l2 l1 dip switches 5.2 electric lock connection (not recommended). See page 6. 5.2.1 door lock controlled with internal power note: not ...

  • Page 7

    -5- 5.2.2 door lock controlled with dry contact note: 1. The external power supply must be used according to the lock. 2. The jumper must be taken off before connecting. 3. Setup the unlock mode of monitor for different lock types. • power-on-to-unlock type:unlock mode=0 (by default) • power-off-to-...

  • Page 8

    -6- 5.2.3 hooking up a door release.

  • Page 9

    -7- 5.3 multi doorstations connection 1 2 on l1 l2 pl s1+ s2+ s- 1 2 on l1 l2 pl s1+ s2+ s- 1 2 on l1 l2 pl s1+ s2+ s- 1 2 on l1 l2 pl s1+ s2+ s- 1 2 on 1 2 on 1 2 on 1 2 on 1# camera id=00 id=10 id=01 id=11 2# camera 3# camera 4# camera dbc4a1 a b c d off on impedance switch + - dps dr-30-24.

  • Page 10

    -8- 5.4.1 basic in-out wiring mode 5.4 multi monitors connection id=00 1 2 on code=14 code=15 note:here we take dt47mg(the monitor) for example. Code=0 + - dps dr-30-24.

  • Page 11

    -9- 5.4.2 with dbc4a1 wiring mode code=0 off on off on dbc4a1 a b c d dbc4a1 a b c d impedance switch impedance switch note:here we take dt47mg(the monitor) for example. Code=2 code=1 code=3 code=12 code=14 code=13 code=15 id=00 1 2 on + - dps dr-30-24.

  • Page 12

    -10- 6.Setup 6.1 dip switches settings of doorstation total 2 bits on the dip switches can be configured.The switches can be modified either before or after installation. Bit state descriptions default setting, id = 0(00), set to the first door station. Id = 1(10), set to the second door station. Id...

  • Page 13

    -11- 1)power-on within 5 seconds; 2)press and hold "b" button for 3 seconds, it will enter the setting the state of prepare. Indicator buzzer beep+,beep (flash) press and hold "b" button for 3 seconds, it will enter the state of ringtone mode setting. Indicator buzzer beep+ (off) followed by pressin...

  • Page 14

    -12- 6.3 unlock time settings 1)power-on within 5 seconds; 2)press and hold "b" button for 3 seconds, it will enter the setting the state of prepare. Indicator buzzer beep+,beep (flash) press and hold "a" button for 3 seconds, it will enter the state of unlock time setting. Indicator buzzer beep+ (o...

  • Page 15

    -13- 7.Cables requirements the maximum distance of the wiring is limited in the dt system. Using different cables may also affect the maximum distance which the system can reach. The farest monitor b a c dbc4a1 monitor monitor monitor with two or four monitors + - dps dr-30-24 note: the thicker the ...