Fetco CBS-2031S User Manual - Programming
9
Programming
Batch Settings
Display
Turn the brewer off by pressing the main power switch.
Press the main power switch again to turn the unit on.
32
The last 2 digits of the model number will display briefly, then S t b.
S t b
Quickly hold the STOP button for 3 seconds.
P r G
The display will show the software version. Example:
0.0 3.2
Press STOP to continue.
Batches are numbered 1 – 2 (single brewers) or 1 – 4 (dual brewers)
Next, the first batch parameter is displayed – batch 1, brew volume
1.1 2.49
Use the SCROLL UP and SCROLL DOWN buttons to adjust.
Press the STOP button to go to the next parameter – brew time.
1.2 4.00
Continue this way until all parameters are programmed for batch #1.
(See the chart below for an explanation of each parameter.)
Next, batch #2 programming begins.
2.0 OFF
Batches 2 and 4 may be disabled by leaving them set to “OFF”.
Change to “ON” to enable. Batches 1 and 3 cannot be disabled.
After all batches are programmed, go to temperature settings.
7 200
(See next page)
MAIN POWER
SWITCH IS
BEHIND
FRONT LEG.
Important! After programming, you must press the HOT WATER button to save the settings and exit
programming mode, or changes will be lost. You may exit programming at any time.
Batch Parameters
X=Batch Number (1 - 4)
Parameter Name
Range
Increment Default
Setting
Comment
X.0
Batch Enabled or
Disabled
On/Off
Batch 1 & 3 = ON
Batch 2 & 4 = OFF
Batch 1 & 3 cannot be
disabled.
X.1
Brew Volume (Liters) 0.94 – 4.72
0.03 or
0.04
2.49 liters
To display gallons,
see # 59 in Advanced
Settings section.
X.2
Brew Time (Min:Sec) 2:00 – 24:00
0:30
4:00 minutes
X.3 Bypass
Percent
(CBS-2031s / 2032s only)
0.00 – 40.0%
1%
0 %
Percentage of total
brew volume
X.4
Prewet Percent
0.00 – 15.0%
1%
0 %
Percentage of total
brew volume
X.5 Prewet
Delay
(Min:Sec)
0:10 – 5:00
0:10
1:00 minute
The time between
prewetting and start of
brew cycle.
X.6
Drip Delay (Min:Sec)
0:30 – 6:00
Minutes
0:10
1:00 minute
The time between end
of brew cycle and
when brew switch
stops blinking.
1.1 2.49
PARAMETER
SETTING
BATCH #
Example: Left Side – Large Batch – Volume 2.49 Liters.