FHF ExResistTel IP2 Operating Instructions Manual

Manual is about: Explosion proof VoIP-telephone

Summary of ExResistTel IP2

  • Page 1

    Explosion proof voip-telephone operating instructions fhf ba 9711 03/13.

  • Page 2

    Page 2 manual exresisttel ip2 ba 9711 03/13 exresisttel ip2 – operating instructions brand names are used with no guarantee that they may be freely employed. Almost all hardware and software designations in this manual are registered trademarks or should be treated as such. All rights reserved. No p...

  • Page 3

    Manual exresisttel ip2 page 3 contents 1 general ............................................................................. 5 1.1 operation ......................................................................... 5 1.2 description ....................................................................

  • Page 4

    Page 4 manual exresisttel ip2 4.1 ec type examination certificate exresisttel ip2 ......... 22 4.2 iecex certificate of conformity exresisttel ip2 .......... 25 4.3 declaration of conformity exresisttel ip2 ................... 26 5 technical data.........................................................

  • Page 5: 1  General

    Manual exresisttel ip2 page 5 1 general the telephone exresisttel ip2 is an explosion proof version of the weatherproof telephone resisttel ip2 / ip152 with all its features. The operating manual is still valid, with the addition of the following items. 1.1operation the telephone type exresisttel ip...

  • Page 6

    Page 6 manual exresisttel ip2 note the installation prescribed in the regulations according to iec/en 60079-14 and the national installation regulations have to be respected. 1.3construction 1.3.1housing the telephone type exresisttel ip2 has a non coloured housing made of an electrostatic conductiv...

  • Page 7

    Manual exresisttel ip2 page 7 1.4electrical characteristic parameter 1.4.1power supply dc (not intrinsically safe) terminal no.: 16, 17 u n = dc 19.2 … 52.8 v u m = dc 53 v i sc = 100 a for this connection cables with a transversal section of 1.5 mm² to 4 mm² are allowed to be used only. 1.4.2power ...

  • Page 8

    Page 8 manual exresisttel ip2 1.4.3lan interface 10/100 base-tx according to ieee 802.3 (not intrinsically safe) terminal no.: 8, 9, 10, 13 u n = ±2.5 v (10 base-tx) respectively u n = ±1 v (100 base-tx) u m = ±7 v u m = dc 57 v for the lan connection it is only allowed to use cables of the type cat...

  • Page 9

    Manual exresisttel ip2 page 9 • u max = dc 50 v i max = 1 a for this connection cables with a transversal section of 0.75 mm² to 4 mm² are allowed to be used only. • u max = dc 30 v i max = 5 a p max = 100 w for this connection cables with a transversal section of 1.5 mm² to 4 mm² are allowed to be ...

  • Page 10

    Page 10 manual exresisttel ip2 the preinstalled cable connection between terminal no. 5 and internal earth connecting bolt of the metal plate is security relevant and must not be interrupted. Caution the air and the creepage distance at the terminals must not be reduced by the kind of connection of ...

  • Page 11

    Manual exresisttel ip2 page 11 1.4.10voltaic isolation of the relay contacts the two potential free relay contacts are safety voltaic separated against each other up to a voltage of 440 v eff ..

  • Page 12: 2  Commissioning

    Page 12 manual exresisttel ip2 2 commissioning for operation and commissioning, the application of standard ieee 802.3 is compulsory. The exresisttel ip2 telephone must be connected to a lan (local area network) connection. The telephone can be powered with poe (power over ethernet). In this case th...

  • Page 13

    Manual exresisttel ip2 page 13 the locking torque of the upper part screws is 1.2 …1.5 nm. Installation and connection must be carried out by competent personnel familiar with electrical and network installations. 2.1.1cable screw caps the preinstalled cable screw caps (4) of the explosion proof tel...

  • Page 14

    Page 14 manual exresisttel ip2 2.1.3inside view of telephone lower part figure 2: inside view of lower part telephone exresisttel ip2 2.1.4drilling diagram figure 3: drilling diagram wall mounting.

  • Page 15

    Manual exresisttel ip2 page 15 the diameter of the drilled hole is dependent on the screw employed (screw diameter max. 8 mm) and the type of supporting base material (steel, wood, concrete, plasterboard etc.) and must be chosen accordingly. 2.1.5connecting plan figure 4: terminals of the explosion ...

  • Page 16

    Page 16 manual exresisttel ip2 if the ethernet interface of the voip telephone is configured to the auto or auto-mdi mode, the rx and tx pairs can be exchanged, because the telephone recognizes in these cases receive and transmit automatically. 2.1.8external power supply connection an external power...

  • Page 17

    Manual exresisttel ip2 page 17 touching. The terminals must be protected again carefully with the cover after connecting. 2.2setup the configuration of the exresisttel ip2 follows as described in the operating manual of the normal resisttel ip2 / ip152 . The manual can be found on the cd attached to...

  • Page 18: 3  Information

    Page 18 manual exresisttel ip2 3 information 3.1service the telephone contains no serviceable parts. 3.2care and maintenance the telephone is maintenance-free. Still, if the operating area is highly contaminated by dust, fat, oil etc., the telephone should be cleaned from time to time. The telephone...

  • Page 19

    Manual exresisttel ip2 page 19 • for repairing only original exchange parts are allowed, which have to be changed professional. Other exchange parts may cause damages and the warranty will be lost. • the required general purpose has to be respected. The telephone must be mounted on a closed rear pan...

  • Page 20

    Page 20 manual exresisttel ip2 caution the telephone is suitable for use in group ii, category 2g and 2d or non-hazardous locations only. Warning – explosion hazard do not disconnect the telephone unless power has been removed or the area is known to be non-hazardous. Warning – explosion hazard subs...

  • Page 21

    Manual exresisttel ip2 page 21 • if electrical connections must be carried through in the hazardous area, the enclosure must be opened and closed as follows: o remove voltage from the telephone. O loosen the fastening screws from the upper case. O remove the upper case and unfasten the keypad cable....

  • Page 22: Declarations And Approvals

    Page 22 manual exresisttel ip2 4 declarations and approvals 4.1ec type examination certificate exresisttel ip2.

  • Page 23

    Manual exresisttel ip2 page 23.

  • Page 24

    Page 24 manual exresisttel ip2.

  • Page 25

    Manual exresisttel ip2 page 25 4.2iecex certificate of conformity exresisttel ip2 the iecex certificate of conformity can be seen in the internet at the link: http://iecex.Iec.Ch/iecex/iecexweb.Nsf/421ce8815c53a3afc1257a1e00576486/a1c67f45a48322ebc1257b18004520b2?Opendocument.

  • Page 26

    Page 26 manual exresisttel ip2 4.3declaration of conformity exresisttel ip2.

  • Page 27

    Manual exresisttel ip2 page 27.

  • Page 28: 5  Technical Data

    Page 28 manual exresisttel ip2 5 technical data connection data power supply power over ethernet refer to ieee 802.3af or external power supply voltage poe 48v dc (min. 44v, max. 57v). The power has to be transmitted at 10/100 mbit/s ethernet connections only with the unused pairs of data lines. Poe...

  • Page 29

    Manual exresisttel ip2 page 29 environment conditions operation environment -40°c…+60°c transport and storage temperature -40°c…+80°c according to en/iec60721 air humidity 75 % conformities degree of protection of enclosure ip66 according to en/iec 60529 degree of protection against external mechani...

  • Page 30