FHF FernTel 3 Z2 Operating Manual - page 6
6
Dimensions connecting cable / cable entry
Cable entries
M20 x 1.5 / M12 x 1.5
Blind plugs
M20 x 1.5 / M12 x 1.5
Connecting cable diameter
6 – 13 mm
Connection potential compensation
1.5 – 4 mm
2
Ambient temperature range and explosion protection
Type of protection
II 3 G Ex nA L IIC T5
II 3 D Ex tD A22 IP65 80°C
Ambient operating temperature
-20°C
≤
Ta
≤
+55°C
Storage and transport temperature
-25°C
≤
T
≤
+70°C
Housing degree of protection
IP 65
Labelling
Company
FHF Funke+Huster Fernsig GmbH
Type
FernTel 3 Z2
20°C
≤
Ta
≤
+55°C IP 65 Ui = 66 Vdc / 90 Vac
II 3 G Ex nA L IIC T5 /
II 3 D Ex tD A22 IP65 80°C
DEKRA
BVS 07 ATEX E 098
Do not open while energized.
For cleaning moist cleaning-rag must be used
CE 0158
II 3 G Ex nA L IIC T5 /
II 3 D Ex tD A22 IP65 80°C
IECEx
Ex nAnL IIC T5
IECEx BVS 08.0008