FHF FernTel IP Z2 UL Manual

Manual is about: Explosion proof UL certified VoIP telephone

Summary of FernTel IP Z2 UL

  • Page 1

    Explosion proof ul certified voip telephone manual fhf ba 9620-51 09/12 ferntel ip z2 ul tabletop unit.

  • Page 2

    2 manual ferntel ip z2 ul ba 9620-51 0 ferntel ip z2 ul –manual brand names are used with no guarantee that they may be freely employed. Almost all hardware and software designations in this manual are registered trademarks or should be treated as such. All rights reserved. No part of this manual ma...

  • Page 3

    Manual ferntel ip z2 ul 3 contents 1 general ............................................................................. 4 1.1 operation ......................................................................... 4 1.2 description ........................................................................

  • Page 4: 2  Commissioning

    4 manual ferntel ip z2 ul 1general the ferntel ip z2 ul telephone is an explosion proof ul certified version of the weatherproof ferntel ip / ip150 telephone with all its features. The operating manual is still valid, with the addition of the following items. 1.1operation the ferntel ip z2 ul teleph...

  • Page 5

    Manual ferntel ip z2 ul 5 rj45 plug pin spare-pair supply phantom supply 1 rx+ rx+ / v- rx+ / v+ 2 rx- rx- / v- rx- / v+ 3 tx+ tx+ / v+ tx+ / v- 4 v+ 5 v- 6 tx- tx- / v+ tx- / v- 7 v- 8 v- upon connecting the cable, please make sure the exposed conductors are placed in the plug connector and are sec...

  • Page 6: 3  Information

    6 manual ferntel ip z2 ul the ferntel ip z2 ul delivery includes a bag with a connector socket with a cut-and clamp device for connecting the lan cable with the short, 8 pin cable piece within the telephone. Follow the instructions on the bag for shortening and placing the individual conductors and ...

  • Page 7

    Manual ferntel ip z2 ul 7 3.2care and maintenance the telephone is maintenance-free. Still, if the operating area is highly contaminated by dust, fat, oil etc., the device should be cleaned from time to time. The device may only be cleaned using a damp cloth in order to avoid electrostatic charging....

  • Page 8

    8 manual ferntel ip z2 ul • the required general purpose has to be respected. The device must be mounted on a closed rear panel in vertical mode or used as a desktop unit. • a magnetic field with disturbing frequencies can adjust a disturbance of the acoustic quality. Pay attention to an acceptable ...

  • Page 9

    Manual ferntel ip z2 ul 9 caution the equipment is suitable for use in class i, division 2, groups a, b, c and d or non-hazardous locations only. Warning – explosion hazard do not disconnect equipment unless power has been removed or the area is known to be non-hazardous. Warning – explosion hazard ...

  • Page 10

    10 manual ferntel ip z2 ul • if electrical connections must be carried through in the hazardous area, the enclosure must be opened and closed as follows: o remove voltage from the device. O loosen the fastening screws from the keypad insert. O remove the keypad insert and unfasten the keypad cable. ...

  • Page 11: Declarations And Approvals

    Manual ferntel ip z2 ul 11 4 declarations and approvals 4.1ul certificates ferntel ip z2 ul page page.

  • Page 12

    12 manual ferntel ip z2 ul page.

  • Page 13: 5  Technical Data

    Manual ferntel ip z2 ul 13 5 technical data connection data power supply power over ethernet refer to ieee 802.3af voltage 48v dc (min. 44v, max. 57v) power 3,5 w p_ poe ” 4 w poe class 0 current i dc_poe ” 100 ma electrical ratings rated voltage: dc 48 v max. Input voltage: dc 57 v connection rj45 ...

  • Page 14

    14 manual ferntel ip z2 ul transport and storage temperature -25°c…+70°c (-13°f…+158°f) air humidity max. 75 % rel., condensed applied harmonized standards and regulations − ul50/ul50e − ul60950-1 − ul60950-22 − ansi/isa 12.12.01-2011 − fcc part 15 control numbers 3msc, 4hg9 file numbers e304856, e3...

  • Page 16

    Subject to alterations or errors fhf funke + huster fernsig gmbh gewerbeallee 15-19 · d-45478 mülheim an der ruhr phone +49 / 208 / 82 68-0 · fax +49 / 208 / 82 68-286 http://www.Fhf.De · e-mail: info@fhf.De.