    Fpi fireplace products international ltd. 6988 venture st., delta, bc canada, v4g 1h4 10/04/11 tested by: installer : please complete the details on the back cover and leave this manual with the homeowner. Homeowner: please keep these instructions for future reference. Regency high efficiency epa ce...

  • Page 2

    Fpi fp90 wood fireplace 2 thank-you for purchasing a regency fireplace product. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. This product has been certified by the environmental protection agency of the united states. This means that it ...

  • Page 3

    Fpi fp90 wood fireplace 3.

  • Page 4: Table  Of  Contents

    Fpi fp90 wood fireplace 4 table of contents safety label safety label for fp90...................................................5 installation product details ..............................................................6 epa certified ..........................................................6 op...

  • Page 5: Safety Label

    Fpi fp90 wood fireplace 5 safety label safety label for fp90 this is a copy of the label that accompanies each regency fireplace. It is located inside the lower louver opening on the left side. We have printed a copy of the contents here for your review. Safety label note: regency units are constant...

  • Page 6: Installation

    Fpi fp90 wood fireplace 6 inst alla tion installation product details epa certified emissions : 3.72 g/hr efficiency (epa) : 63% btu/hr (epa) : 11,720 (lo) to 42,400 (hi) flue size : 8" (203mm) diameter log size : 20" (508mm) shipping weight : 612 lbs (278kg) stripped weight : 570 lbs (259kg) option...

  • Page 7: Installation

    Fpi fp90 wood fireplace 7 inst alla tion installation 6) use solid fuel only. Do not use artificial logs containing petroleum products, chemical chimney cleaners, gas logs, gas lighters, salt contaminated wood or flame colorants in your fireplace. When using compressed sawdust logs use only at 1/3 c...

  • Page 8: Installation

    Fpi fp90 wood fireplace 8 inst alla tion 38" 43- 5/8" 14- 5/8" 13-3/8" 28" 9-5/8" 25" 15" 4-3/4" 50- 1/2" (1283mm) 42- 5/8" 3-5/8" 1-3/8" 7-7/8" 29-1/8" 31" 37-3/8" (1083mm) (92mm) (121mm) (965mm) (1108mm) (371mm) (371mm) (949mm) (787mm) (740mm) (200mm) (35mm) (244mm) (381mm) (635mm) (711mm) unit di...

  • Page 9: Installation

    Fpi fp90 wood fireplace 9 inst alla tion no combustibles on face of unit. Combustibles may not extend to unit face. Do not notch wallboard around standoffs. The fp90 may be placed on or near construction materials. The combustion air kit, fire stop spacer and roof flashings (not chase flashings) may...

  • Page 10: Installation

    Fpi fp90 wood fireplace 10 inst alla tion building structures cannot encroach on chase installation of nailing strips 1) assemble 3 nailing strip spacer plates to the left and the right nailing strips as shown below. Left nailing strip nailing strip spacer plates right nailing strip x 12 right naili...

  • Page 11: Installation

    Fpi fp90 wood fireplace 11 inst alla tion fire stop firestop straightrun for 8"(203mm) hot air duct unit projects out flush with non-combustible material 2 x 4 framing 2 x 6 framing 10" 2 x 6 wall with a 2 x 4 header stud 84" (2137mm) 50-3/4" (1289mm) 55-3/4" (1416mm) 42-5/8" (1083mm) (254mm) 2 x 4 ...

  • Page 12: Installation

    Fpi fp90 wood fireplace 12 inst alla tion ventilated chase pan before you start check your inventory list to be sure you have all the necessary parts supplied in good usable condition. Check for any concealed damage. Check the operation of the combustion air damper. When the damper is in the fully c...

  • Page 13: Installation

    Fpi fp90 wood fireplace 13 inst alla tion installation measurements / framing details installation 3" (76mm) stand-off 2x4 framing front of unit only combustion air to outside 38" (965mm) 19" (483mm) 30" (762mm) 60" (1524mm) wide inside min. Unit to be centere note: framing to be agai stand-offs onl...

  • Page 14: Installation

    Fpi fp90 wood fireplace 14 inst alla tion there is also 1" unit base standoffs that are supplied with the unit. These are optional and are to be used to raise the unit. The thickness of the finished hearth will dictate the height of the stove. Please be careful to ensure that the bottom louver will ...

  • Page 15: Installation

    Fpi fp90 wood fireplace 15 inst alla tion the performance of your unit is governed to a very large extent by the chimney system. Too short a chimney can produce poor drafting which in turn can cause difficult start-up, dirty glass, smoking out door and even reduced heat output. Too tall a chimney ma...

  • Page 16: Installation

    Fpi fp90 wood fireplace 16 inst alla tion installing the outside air kit combustion air is fed to the firebox through a connection on the rear lower left side of the unit. A free flowing supply of air must be available to this opening at all times. Combustion air may be taken from inside the buildin...

  • Page 17: Installation

    Fpi fp90 wood fireplace 17 inst alla tion plan view jakel ax-2495 blower angle view fan transfer plate right view front view fan 910-175 ax-3088 910-903 910-516 ground neutral - from fan 910-811 thermodisc 910-142 p60t12 variable switch 910-330 919-885 power chord 910-619 ground hot - to va riable s...

  • Page 18: Installation

    Fpi fp90 wood fireplace 18 inst alla tion flex vent discharge vent grille discharge vent frame connecting collar clamp flex vent insulation strips 1) remove the screw from the vent hole cover (vent cover 'a') on top of the unit. 2) take the connector collar and press and rotate it into the hole to c...

  • Page 19: Installation

    Fpi fp90 wood fireplace 19 inst alla tion . . . . . . . . . . . . . Metal filler strips metal filler strips middle up top up left side up right side up a c b b non-combustible material 2" (51mm) x 4" (102mm) masonry retainer kit option for a non-selfsupporting veneer finish only. 1) framing and plyw...

  • Page 20: Installation

    Fpi fp90 wood fireplace 20 inst alla tion non-combustible material metal filler strips stand-off spacers metal filler strip 60" (1524mm) c a b b 3/4" (19mm) 2-1/2" (64mm) 1-1/4"(32mm) 48" (1219mm) 29" (637mm) 2-1/2" (64mm) 6) depending on the height of the hearth in front of the unit, it may be nece...

  • Page 21: Installation

    Fpi fp90 wood fireplace 21 inst alla tion side panel top panel insulation top brick bottom vermiculite masonry liner / bricks insulated refractory panels are included to extend the life of the fireplace and help radiate heat more evenly. Make sure insulating paper is in place along the bottom, side ...

  • Page 22: Installation

    Fpi fp90 wood fireplace 22 inst alla tion ash drawer kit option during constant use, ashes should be removed every few days. The ash drawer kit option provides a convenient and easy way to keep your wood stove clean. This ash drawer kit can only be used with the fireplace unit. Safety precautions 1)...

  • Page 23: Fp90

    Fpi fp90 wood fireplace 23 inst alla tion fan installation 01/13/11 918-437 fp90 fan installation note: if optional ashtray is installed, it must be removed before installing the fan. The receptacle box must be wired for the fan cable to be plugged into. 1) remove the thumb screw from the fan transf...

  • Page 24: Installation

    Fpi fp90 wood fireplace 24 inst alla tion masonry cover plate installation 5° install four #8x1/2 screws at these locations to attach the surround template sides to the top. Note: sides should be assembled flanges are on the slotted holes on right side only 43.000" (1092mm) 39.250" (997mm) once the ...

  • Page 25: Installation

    Fpi fp90 wood fireplace 25 inst alla tion with the same mounting screws as the surround. Install the surround template onto the unit warning: keep masonry material at least 1/2" (13mm) from this top facing guide. This is required to prevent masonry facing material from hitting the top stiffener loca...

  • Page 26: Wood Fireplace

    Fpi fp90 wood fireplace 26 inst alla tion finishing trim kit installation 10/10/06 918-442a wood fireplace ex90 / r90 finishing trim kit page 1 of 2 2x4 framing left side trim right side trim 2x4 framing top trim step #1 non-combustible area 60"w x 51-5 /8"h (1524mm w x 1311mm h) 2x4 heade r (on edg...

  • Page 27: Wood Fireplace

    Fpi fp90 wood fireplace 27 inst alla tion 10/10/06 918-442a wood fireplace ex90 / r90 2) make sure the insulation under the top stand-off is up against the back of the top nailing strip. 3) fasten the nailing strips to the framing. 4) install both the left and right side trim (see labels for orienta...

  • Page 28: Ex90 / R90

    Fpi fp90 wood fireplace 28 inst alla tion fireplace screen installation 01/12/06 918-444 fireplace screen installation ex90 / r90 installing the handles on the screen 1) 1 or 2 handles can be installed on the screen. Layout location of the handle using the backing plate as a guide and widen two hole...

  • Page 29: R90

    Fpi fp90 wood fireplace 29 inst alla tion regency louver installation 08/23/05 918-433 r90 wood fireplace regency louvers installing the top louver 1) add two (2) screws (¼-20 x ½”) to the front of the fi replace for mounting the top louver. The screws must be left loose to allow the top louver to s...

  • Page 30: Ex90

    Fpi fp90 wood fireplace 30 inst alla tion 11/12/09 918-434 ex90 wood fireplace excalibur faceplate installing the facing guide 1) secure the left and right facing guides to the fi re- place with seven (7) screws (#10 x 1”) on each side. Holes must be pre-drilled. 2) install the top louver opening ad...

  • Page 31: Wood Fireplace

    Fpi fp90 wood fireplace 31 inst alla tion excalibur accent kit installation 08/23/05 918-438 wood fireplace ex90 accent kit installation 3) remove the 2 studs on the sides of the hood. Insert the new studs through the holes and secure them by fi rst putting on the washer and then tighten the nut. 1)...

  • Page 32

    Fpi fp90 wood fireplace 32 hea tw a ve kit heatwave kit (not epa approved) diagram 1: guide for possible air duct runs and locations. Keep duct length and number of bends to a miniumum. Maximum duct length is 20 ft. (6.1m) per kit. Listings and code approvals this kit has been approved for use with ...

  • Page 33

    Fpi fp90 wood fireplace 33 hea tw a ve kit heatwave kit (not epa approved) minimum framing clearances * wall studs must be 16" on center for mounting fan housing. * fan housing: maintain a 1/4" (6mm) clearance from fan housing to combustible material. * wall registers must be 4"(102mm) from floor ab...

  • Page 34

    Fpi fp90 wood fireplace 34 hea tw a ve kit heatwave kit (not epa approved) diagram 4 4) install the variable speed wall rheostat (with off setting) in a convenient location. This switch controls the fan operation. 5) wire 120v ac service to the wall rheostat and from the wall rheostat to the fan jun...

  • Page 35: Operating Instructions

    Fpi fp90 wood fireplace 35 opera tion operating instructions draft control both the primary and air wash drafts are controlled by the control rod located behind the bottom louver. To increase your draft, pull to the right for open , to decrease push to the left for closed. Warning: do not build the ...

  • Page 36: Maintenance

    Fpi fp90 wood fireplace 36 maintenance plated finishes the optional plated finishes on the louvers and surrounds requires little maintenance and needs only to be cleaned with a damp cloth. Do not use abrasive materials or chemical cleaners, as they may harm the finish and void the warranty. Keep doo...

  • Page 37: Parts List

    Fpi fp90 wood fireplace 37 par ts list parts list parts list- firebox & body 16 12 13 15 14 4 2 1 8 7 6 5 3 part # description 1) 001-127 heat deflector top 001-128 stand off top - right side 001-129 stand off top - left side 001-130 support top stand off 2) 001-122 nailing strip - top 001-123 naili...

  • Page 38: Parts List

    Fpi fp90 wood fireplace 38 par ts list parts list parts list- baffles, door, options steel handle - left door steel handle - right door anchor bracket - left handle door latch [double] double door glass retaining rod hinge mounting plate - left male hinge pin - male hinge mounting plate - right male...

  • Page 39: Warranty

    Fpi fp90 wood fireplace 39 warranty warranty revised: 01-04-07 regency fireplace products are designed with reliability and simplicity in mind. In addition, our internal quality assurance team carefully inspects each unit thoroughly before it leaves our door. Fpi fireplace products international ltd...

  • Page 40: Register Your Regency

    Printed in canada regency is a trademark of fpi fireplace products international ltd. © copyright 2011, fpi fireplace products international ltd. All rights reserved. Installer: please complete the following information dealer name & address: ______________________________________________ __________...