- DL manuals
- FPI
- Indoor Fireplace
- Hamilton H15
- Owners & Installation Manual
FPI Hamilton H15 Owners & Installation Manual - Installation
16
Hampton® H15-1 Direct Vent Freestanding Gas Stove
INSTALLATION
Pipe Length
Vertical
Termination
Cap
Storm Collar
Flashing
Ceiling Firestop
24" Pipe
Length
Adj.Pipe Length
11" - 14-5/8"
90 Elbow
o
Horizontal
Termination
Cap
Wall Thimble
Vinyl Siding
Standoff (Optional)
RIGID PIPE VENTING SYSTEMS
Horizontal or Vertical Terminations
Alternate
Horizontal
Termination
Caps
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
This product has been evaluated by Intertek
for using a Rigid Pipe Adaptor in conjunction
with Duravent Direct-Vent, Selkirk Direct-Temp,
Ameri Vent Direct venting and Security Secure
Vent systems. Use of these systems with the
Rigid Pipe adaptor is deemed acceptable
and does not affect the Intertek WHI listing of
components.
WARNING:
Do not combine venting components from
different venting systems.
However use of the the AstroCap
TM
and FPI
Riser is acceptable with all systems.
The FPI AstroCap
TM
and FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent
®
Direct Vent,
American Metal Products Ameri Vent Direct Vent, Security Secure Vent
®
, Selkirk Direct-Temp. AstroCap
TM
is a proprietary trademark of FPI Fireplace
Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
Max.
Summary of Hamilton H15
Page 1
Fpi fireplace products international ltd. 6988 venture st., delta, bc canada, v4g 1h4 918-516c models: h15-ng1 natural gas h15-lp1 propane 04/12/11 h15 direct vent gas fireplace owners & installation manual warning: if the information in these instructions are not followed exactly, a fi re or explos...
Page 2
2 hampton® h15-1 direct vent freestanding gas stove hampton ® direct vent freestanding gas stove to the new owner: congratulations! You are the owner of a state-of-the-art hampton ® gas stove by fpi fireplace products international ltd. The h15-1 is a hand crafted appliance and has been designed to ...
Page 3: Safety Label
Hampton® h15-1 direct vent freestanding gas stove 3 hampton® h15-1 direct vent freestanding gas stove 3 safety label dimensions unit dimensions.
Page 4: Dimensions
4 hampton® h15-1 direct vent freestanding gas stove dimensions conversion from ng to lp ..........................................31 log set installation ......................................................34 optional wall thermostat ...........................................36 optional remote co...
Page 5: Safety Label
Hampton® h15-1 direct vent freestanding gas stove 5 safety label this is a copy of the label that accompanies each direct vent freestanding gas stove. We have printed a copy of the contents here for your review. Note: hampton ® units are constantly being improved. Check the label on the unit and if ...
Page 6: Requirements
6 hampton® h15-1 direct vent freestanding gas stove requirements 5.08: modifications to nfpa-54, chapter 10 (2) revise 10.8.3 by adding the following additional requirements: (a) for all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in who...
Page 7: Installation
Hampton® h15-1 direct vent freestanding gas stove 7 installation important message save these instructions the direct vent freestanding gas stove must be installed in accordance with these instruc- tions. Carefully read all the instructions in this manual fi rst. Consult the building authority havin...
Page 8: Installation
8 hampton® h15-1 direct vent freestanding gas stove installation 1) provide adequate clearances for servicing, proper operation and around the air openings into the combustion chamber. 2) the appliance must be installed on a fl at, solid, continuous surface (e.G. Wood, metal, con- crete). This may b...
Page 9: Installation
Hampton® h15-1 direct vent freestanding gas stove 9 installation locating your gas stove when selecting a location for your stove, ensure that the clearances listed above are met as well as ensuring that there is adequate accessibility for servicing and proper operation. Manufactured mobile home add...
Page 10: Installation
10 hampton® h15-1 direct vent freestanding gas stove installation 9) remove 2 screws from unit. 10) place grommet in rear plate through the bottom of the opening as shown below. 11) place the blower close to the base of the unit and feed the wires through the grommet in the rear plate. Grommet rear ...
Page 11: Installation
Hampton® h15-1 direct vent freestanding gas stove 11 installation 16) slide the rear access panel back into position and secure with 2 screws. Warning: electrical grounding instructions this appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and shou...
Page 12: Installation
12 hampton® h15-1 direct vent freestanding gas stove installation installation precautions these venting systems are engineered products that have been designed and tested for use with the h15-ng1, and h15-lp1. The warranty will be voided and serious fi re, health or other safety haz- ards may resul...
Page 13: Installation
Hampton® h15-1 direct vent freestanding gas stove 13 installation exterior vent terminal locations minimum clearance requirements canada 1 usa 2 a clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm) b clearance to window or door that may be opened 12"(30cm) 9" (23cm) c cleara...
Page 14: Installation
14 hampton® h15-1 direct vent freestanding gas stove installation 4” x 6-5/8” rigid pipe cross reference chart components from different manufacturers may not be mixed. Not all rigid pipe components are available directly from fpi. Description simpson direct vent pro ® selkirk direct temp™ american ...
Page 15: Installation
Hampton® h15-1 direct vent freestanding gas stove 15 installation description simpson direct vent pro ® selkirk direct temp™ american metal products® amerivent direct metal-fab™ sure seal security secure- vent® icc excel direct attic insulation shield 12” 46dva-is n/a@ fpi n/a 4dais12 n/a sv4rsa n/a...
Page 16: Installation
16 hampton® h15-1 direct vent freestanding gas stove installation pipe length vertical termination cap storm collar flashing ceiling firestop 24" pipe length adj.Pipe length 11" - 14-5/8" 90 elbow o horizontal termination cap wall thimble vinyl siding standoff (optional) rigid pipe venting systems h...
Page 17: Installation
Hampton® h15-1 direct vent freestanding gas stove 17 installation h1 h v horizontal venting with two (2) 90 o elbows option v h + h1 a) 1' min. 3' max. B) 2' min. 4' max. C) 3' min. 5' max. D) 4' min. 6' max. E) 5' min. 7' max. F) 6' min. 8' max. Horizontal venting with two (2) 90 o elbows option h ...
Page 18: Installation
18 hampton® h15-1 direct vent freestanding gas stove installation h1 h v vertical venting with two (2) 90 o elbows option v h v + v1 a) 1' min. 4' max. 2' min. B) 2' min. 5' max. 3' min. C) 3' min. 6' max. 4' min. D) 4' min. 7' max. 5' min. E) 5' min. 8' max. 6' min. Vertical venting with two (2) 90...
Page 19: Installation
Hampton® h15-1 direct vent freestanding gas stove 19 installation offset to vertical terminations venting arrangements - horizontal terminations venting arrangements vertical terminations systems for residential manufactured and mobile homes the shaded area in the diagram below shows all allowable c...
Page 20: Installation
20 hampton® h15-1 direct vent freestanding gas stove installation venting arrangements - vertical terminations with co-linear flex system for both residential & manufactured homes into masonry fireplaces the shaded area in the diagram shows the allowable vertical terminations. Vertical termination w...
Page 21: Installation
Hampton® h15-1 direct vent freestanding gas stove 21 installation dv stove horizontal vent kit (#946-116 & #946-216) installation review the following sequence of instructions which are typical of most installations. The sequence may vary depending on wall thick- ness. Refer to the "exterior vent te...
Page 22: Installation
22 hampton® h15-1 direct vent freestanding gas stove installation note: the pipe seam should be fac- ing down. Note: to make the installation more aes- thetically pleasing, we recommend framing out a square that the cap can be mounted on. 3) attach the 4" dia. Fl ex liner to the vent terminal ensuri...
Page 23: Installation
Hampton® h15-1 direct vent freestanding gas stove 23 installation residential and manufactured homes / mobile homes minimum horizontal termination installations planning your venting installation see the "exterior vent terminal locations" section for requirements. When planning your installation, it...
Page 24: Installation
24 hampton® h15-1 direct vent freestanding gas stove installation basic horizontal kit 1 90 o elbow 1 wall thimble cover 1 horiz. Sq. Term. Cap dura-vent termination kit planning your dura-vent installation there are two basic types of dura-vent direct vent system installations: horizontal terminati...
Page 25: Installation
Hampton® h15-1 direct vent freestanding gas stove 25 installation please review your product to make sure you have everything you need. In the event that you are missing any part, contact your dealer. Note: these are the minimum pieces required. Other parts may be required for your particular instal...
Page 26: Installation
26 hampton® h15-1 direct vent freestanding gas stove installation diagram 7 vertical terminations 1) maintain the 1-1/4" clearances (air spaces) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafter, or other nearby combustible surfaces. Do not pack air spaces with in...
Page 27: Installation
Hampton® h15-1 direct vent freestanding gas stove 27 installation offset chart diagram 12 7) ensure vent is vertical and secure the base of the fl ashing to the roof with roofi ng rails, slide storm collar over the pipe section and seal with a mastic. 8) install the vertical termination cap by twist...
Page 28: Installation
28 hampton® h15-1 direct vent freestanding gas stove installation converting class-a metal chimney or masonry chimney to direct vent system there are two different types of direct vent conver- sion systems listed below. Follow the appropriate directions for your installation. A) through an existing ...
Page 29: Installation
Hampton® h15-1 direct vent freestanding gas stove 29 installation 4) assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up through the support box and fl ashing to proper height as per dia. 12, local codes. Ensure that all pipe and elbow connections a...
Page 30: Installation
30 hampton® h15-1 direct vent freestanding gas stove installation gas pipe pressure testing the appliance must be isolated from the gas sup- ply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or les...
Page 31: Installation
Hampton® h15-1 direct vent freestanding gas stove 31 installation this conversion must be done by a qualified gas fitter if in doubt do not do this conversion !! Conversion kit# 381-969 from ng to lp each kit contains one lpg conversion kit and one dc sparker kit. Lpg conversion kit contains: qty. P...
Page 32: Installation
32 hampton® h15-1 direct vent freestanding gas stove installation installation of the dc sparker: 19) remove the control panel by unscrewing the 2 screws. 21) plug up the piezo hole with the plastic bushing. 22) attach the dc sparker generator connector to the valve with a screw. 23) remove the stov...
Page 33: Installation
Hampton® h15-1 direct vent freestanding gas stove 33 installation 27) install the plastic bushing over the outside of the hole. 28) attach the ground wire to the dc spark mounting bracket. 29) attach the dc sparker generator wires to the dc sparker. 26) insert both the ground wire and the dc sparker...
Page 34: Installation
34 hampton® h15-1 direct vent freestanding gas stove installation log set installation 1) shut off the gas supply. 2) lift off cast top. Read the instructions below carefully and refer to the diagrams. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with...
Page 35: Installation
Hampton® h15-1 direct vent freestanding gas stove 35 installation 9) place the center cross log on the top of the rear log and position as shown below. Logs must be oriented as shown below. 10) test fi re to ensure proper light off (make sure fl ame fl ows smoothly from one end of burner to the othe...
Page 36: Installation
36 hampton® h15-1 direct vent freestanding gas stove installation 3) install 3 aaa alkaline batteries in transmitter and 4 aa alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation...
Page 37: Installation
Hampton® h15-1 direct vent freestanding gas stove 37 installation wiring diagrams caution: label all wires prior to disconnection when servic- ing controls. Wiring errors can cause improper and dangerous operation. If any of the original wires as supplied with the appliance must be replaced, it must...
Page 38: Installation
38 hampton® h15-1 direct vent freestanding gas stove installation for propane units and units equipped with dc spark boxes* *for installation of the dc spark box refer to the lp conversion instructions in this manual..
Page 39: Installation
Hampton® h15-1 direct vent freestanding gas stove 39 39 installation operating instructions automatic convection fan operation the fan operates automatically - turn the knob at the top right rear corner to adjust to the desired speed. The fan will turn on as the stove comes up to operating temperatu...
Page 40: Operating Instructions
40 hampton® h15-1 direct vent freestanding gas stove 40 operating instructions copy of the lighting plate instructions 1) push in gas control knob slightly and turn to “pilot” position. 2) push in control knob all the way and hold in untilthe pilot lights up. Continue to hold the control knob in for...
Page 41: Maintenance
Hampton® h15-1 direct vent freestanding gas stove 41 maintenance top view of pilot fl ame maintenance instructions 1) always turn off the valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a yea...
Page 42: Maintenance
42 hampton® h15-1 direct vent freestanding gas stove maintenance fan maintenance if your fan requires maintenance or replacement, access to the fan is through the rear access panel on the back of the unit. Important: these fans collect a lot of dust from within your home. Ensure you maintain these f...
Page 43: Maintenance
Hampton® h15-1 direct vent freestanding gas stove 43 maintenance 11) carefully lift the burner tray assembly out. Removing valve if your valve requires maintenance or replacement, use the following instructions: note: always close off the gas supply before removing the valve. 1) if optional fan is i...
Page 44: Parts List
44 hampton® h15-1 direct vent freestanding gas stove parts list main assembly part # description part # description part # description 1) 942-601** casting - top 2) 942-621** casting - side & leg 3) 942-611** casting - front 6) 770-066f top relief plate 7) w260280 top relief plate gasket 8) 770-067f...
Page 45: Parts List
Hampton® h15-1 direct vent freestanding gas stove 45 parts list burner & log assembly part # description 380-574/p valve/pilot assembly - s.I.T. - ng 60) 910-478 valve s.I.T. - ng/lpg 904-434 #47 orifi ce - ng 63) 910-190 piezo ignitor & nut 64) 908-672 control panel decal 65) 490-061 switch plate 9...
Page 46: Notes
46 hampton® h15-1 direct vent freestanding gas stove notes.
Page 47: Warranty
Hampton® h15-1 direct vent freestanding gas stove 47 warranty hampton fireplace products are designed with reliability and simplicity in mind. In addition, our internal quality assurance team carefully inspects each unit thoroughly before it leaves our facility. Fpi fireplace products international ...
Page 48: Register Your Regency
Printed in canada hampton is a trademark of fpi fireplace products international ltd. © copyright 2011, fpi fireplace products international ltd. All rights reserved. Installer: please complete the following information dealer name & address: ______________________________________________ __________...