FPI Hampton H15-LP Owners & Installation Manual - Installation

Manual is about: Direct Vent Gas Fireplace

Summary of Hampton H15-LP

  • Page 1

    Fpi fireplace products international ltd. 6988 venture st., delta, bc canada, v4g 1h4 918-219b models: h15-ng natural gas h15-lp propane 01/09/06 h15 direct vent gas fireplace owners & installation manual warning: if the information in these instructions are not followed exactly, a fire or explosion...

  • Page 2: Hampton

    2 hampton h15 direct vent freestanding gas stove hampton direct vent freestanding gas stove unit dimensions to the new owner: congratulations! You are the owner of a state-of-the-art hampton gas stove by fpi fireplace products international ltd. The h15 is a hand crafted appliance and has been desig...

  • Page 3: Table of Contents

    Hampton h15 direct vent freestanding gas stove 3 table of contents page page support extension - round or square ....................... 25 high elevation ......................................................... 25 gas connection ...................................................... 25 system data...

  • Page 4: Safety Label

    4 hampton h15 direct vent freestanding gas stove this is a copy of the label that accompanies each direct vent freestanding gas stove. We have printed a copy of the contents here for your review. Safety label copy of safety label for h15-ng & h15-lp note: hampton units are constantly being improved....

  • Page 5: Important:

    Hampton h15 direct vent freestanding gas stove 5 important: save these instructions the direct vent freestanding gas stove must be installed in accordance with these instruc- tions. Carefully read all the instructions in this manual first. Consult the building authority hav- ing jurisdiction to dete...

  • Page 6: Installation

    6 hampton h15 direct vent freestanding gas stove installation 5) this appliance is listed for alcove installa- tions, maintain minimum alcove clearances as follows, minimum width of 32-1/2" (825mm), a maximum depth of 36" (914mm), and minimum height of 24" (610mm) from top of unit to ceiling. 6) we ...

  • Page 7: Locating  Your

    Hampton h15 direct vent freestanding gas stove 7 locating your gas stove when selecting a location for your stove, en- sure that the clearances listed above are met as well as ensuring that there is adequate acces- sibility for servicing and proper operation. Manufactured mobile home additional requ...

  • Page 8: Installation

    8 hampton h15 direct vent freestanding gas stove installation 9) remove 2 screws from unit. 10) place grommet in rear plate through the bottom of the opening as shown below. 11) place the blower close to the base of the unit and feed the wires through the grommet in the rear plate. 16) slide the rea...

  • Page 9: Installation

    Hampton h15 direct vent freestanding gas stove 9 installation precautions these venting systems are engineered prod- ucts that have been designed and tested for use with the h15-ng, and h15-lp. The warran- ty will be voided and serious fire, health or other safety hazards may result from any of the ...

  • Page 10: Installation

    10 hampton h15 direct vent freestanding gas stove exterior vent terminal locations a= clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) b= clearance to window or door that may be opened *(12"/30cm) c= clearance to permanently closed window *(min. 12"/30cm) d= vertical clearanc...

  • Page 11: Installation

    Hampton h15 direct vent freestanding gas stove 11 installation 946-506/p vent guard (optional) 640-530/p riser vent terminal 946-205 vinyl siding shield for riser vent terminal 946-208/p vent guard (optional) - riser vent terminal 946-523/p astrocap horizontal cap 946-206 vinyl siding standoff - ast...

  • Page 12: Rigid Pipe Venting Systems

    12 hampton h15 direct vent freestanding gas stove rigid pipe venting systems horizontal or vertical terminations alternate horizontal termination caps installation the fpi astrocap tm and fpi riser vent terminal is certified for installations using fpi venting systems as well as simpson dura-vent®, ...

  • Page 13: Installation

    Hampton h15 direct vent freestanding gas stove 13 horizontal venting with two (2) 90 o elbows option v h + h1 a) 1' min. 3' max. B) 2' min. 4' max. C) 3' min. 5' max. D) 4' min. 6' max. E) 5' min. 7' max. F) 6' min. 8' max. Horizontal venting with two (2) 90 o elbows option h v h + h1 a) 1' max. 1' ...

  • Page 14: Installation

    14 hampton h15 direct vent freestanding gas stove vertical venting with two (2) 90 o elbows option v h v + v1 a) 1' min. 4' max. 2' min. B) 2' min. 5' max. 3' min. C) 3' min. 6' max. 4' min. D) 4' min. 7' max. 5' min. E) 5' min. 8' max. 6' min. Vertical venting with two (2) 90 o elbows with these op...

  • Page 15: Installation

    Hampton h15 direct vent freestanding gas stove 15 installation offset to vertical terminations venting arrangements - horizontal terminations venting arrangements vertical terminations systems for residential manufactured and mobile homes the shaded area in the diagram below shows all allowable comb...

  • Page 16: Installation

    16 hampton h15 direct vent freestanding gas stove venting arrangements - vertical terminations with co-linear flex system for both residential & manufactured homes into masonry fireplaces the shaded area in the diagram shows the allowable vertical terminations. Vertical termination with co-linear fl...

  • Page 17: Installation

    Hampton h15 direct vent freestanding gas stove 17 dv stove horizontal vent kit (#946-116 & #946-216) installation review the following sequence of instructions which are typical of most installations. The sequence may vary depending on wall thick- ness. Refer to pages 10 to 16 for vent location and ...

  • Page 18: Installation

    18 hampton h15 direct vent freestanding gas stove installation note: the pipe s e a m should be f a c i n g down. Note: to make the installation more aes- thetically pleasing, we recom- mend framing out a square that the cap can be mounted on. Note: if installing ter- m i n a t i o n o n a siding co...

  • Page 19: Installation

    Hampton h15 direct vent freestanding gas stove 19 installation residential and manufactured homes / mobile homes minimum horizontal termination installations planning your venting installation see page 10 for exterior vent termina- tion requirements. When planning your installation, it will be nec- ...

  • Page 20: Dura-Vent Termination Kit

    20 hampton h15 direct vent freestanding gas stove dura-vent basic horizontal kit # 970 1 90 o elbow 1 wall thimble cover 1 horiz. Sq. Term. Cap dura-vent termination kit planning your dura-vent installation there are two basic types of dura-vent direct vent system installations: horizontal termina- ...

  • Page 21: Installation

    Hampton h15 direct vent freestanding gas stove 21 installation dura-vent venting components the simpson dura-vent direct vent system offers a complete line of component parts for installation of both horizontal and vertical instal- lation. Many items are offered in decorative black, as well as galva...

  • Page 22: Dura-Vent Vertical

    22 hampton h15 direct vent freestanding gas stove diagram 7 dura-vent vertical termination 1) maintain the 1-1/4" clearances (air spaces) to combustibles when passing through ceilings, walls, roofs, enclo- sures, attic rafter, or other nearby combustible surfac- es. Do not pack air spaces with insul...

  • Page 23: Installation

    Hampton h15 direct vent freestanding gas stove 23 installation offset chart diagram 12 7) ensure vent is vertical and secure the base of the flashing to the roof with roofing rails, slide storm collar over the pipe section and seal with a mastic. 8) install the vertical termination cap by twist lock...

  • Page 24: Converting A Class-

    24 hampton h15 direct vent freestanding gas stove converting a class- a metal chimney or masonry chimney to a direct vent system there are two different types of direct vent conversion systems listed below. Follow the appropriate directions for your installation. A) through an existing factory built...

  • Page 25: High Elevation

    Hampton h15 direct vent freestanding gas stove 25 half of the flashing should be under the shingles. 4) assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up through the support box and flashing to proper height as per dia. 12, local codes. Ensure tha...

  • Page 26: Installation

    26 hampton h15 direct vent freestanding gas stove installation gas pipe pressure testing the appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less tha...

  • Page 27: Installation

    Hampton h15 direct vent freestanding gas stove 27 installer notice: these instructions must be left with the appliance. Burner orifice 7) unscrew the pilot orifice with the allen key and replace with the lp pilot orifice in the kit. 8) remove burner orifice with a 1/2" wrench and discard. Use a wren...

  • Page 28: Log Set Installation

    28 hampton h15 direct vent freestanding gas stove a) d) b) c) log set installation 1) shut off the gas supply. 2) lift off cast top. Read the instructions below carefully and refer to the dia- grams. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with t...

  • Page 29: Installation

    Hampton h15 direct vent freestanding gas stove 29 9) place the center cross log on the locating pin in the top of the rear log and position as shown below. Logs must be oriented as shown below. 10) test fire to ensure proper light off (make sure flame flows smoothly from one end of burner to the oth...

  • Page 30: Optional Remote

    30 hampton h15 direct vent freestanding gas stove caution do not connect the millivolt remote control wires to the 120v wires. 3) install 3 aaa alkaline batteries in transmit- ter and 4 aa alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver ...

  • Page 31: Installation

    Hampton h15 direct vent freestanding gas stove 31 wiring diagram - h15-ng & h15-lp caution: label all wires prior to disconnection when servicing con- trols. Wiring errors can cause im- proper and dangerous operation. If any of the original wires as supplied with the appliance must be replaced, it m...

  • Page 32: Automatic

    32 hampton h15 direct vent freestanding gas stove automatic convection fan operation the fan operates automatically - turn the knob at the top right rear corner to adjust to the desired speed. The fan will turn on as the stove comes up to operating temperature. After the unit has been turned off and...

  • Page 33: Operating Instructions

    Hampton h15 direct vent freestanding gas stove 33 copy of the lighting plate instructions operating instructions.

  • Page 34: Maintenance

    34 hampton h15 direct vent freestanding gas stove maintenance top view of pilot flame maintenance instructions 1) always turn off the valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. W...

  • Page 35: Fan Maintenance

    Hampton h15 direct vent freestanding gas stove 35 fan maintenance if your fan requires maintenance or replace- ment, access to the fan is through the rear access panel on the back of the unit. Important: these fans collect a lot of dust from within your home. Ensure you maintain these fan motors on ...

  • Page 36: Removing Valve

    36 hampton h15 direct vent freestanding gas stove 11) carefully lift the burner tray assembly out. Removing valve if your valve requires maintenance or replace- ment, use the following instructions: note: always close off the gas supply before removing the valve. 1) if optional fan is installed, dis...

  • Page 37: Parts List

    Hampton h15 direct vent freestanding gas stove 37 parts list main assembly part # description part # description part # description 1) 942-601** casting - top 2) 942-621** casting - side & leg 3) 942-611** casting - front 6) 770-066f top relief plate 7) w260280 top relief plate gasket 8) 770-067f pl...

  • Page 38: Burner & Log Assembly

    38 hampton h15 direct vent freestanding gas stove burner & log assembly part # description parts list 380-574/p valve/pilot assembly - s.I.T. - ng 60) 910-378 valve s.I.T. - natural gas 904-434 #47 orifice - ng 63) 910-190 piezo ignitor & nut 64) 908-672 control panel decal 65) 490-061 switch plate ...

  • Page 39: Warranty

    Hampton h15 direct vent freestanding gas stove 39 warranty hampton fireplace products are designed with reliability and simplicity in mind. In addition, our internal quality assurance team carefully inspects each unit thoroughly before it leaves our facility. Fpi fireplace products international ltd...

  • Page 40: Http://www.Hampton-Fire.Com

    Installer: please complete the following information dealer name & address: ________________________________________________ ______________________________________________________________________ installer: ______________________________________________________________ phone #: _____________________...