FPI Hampton HI200 Owners & Installation Manual

Manual is about: Wood Cast Insert

Summary of Hampton HI200

  • Page 1

    Fpi fireplace products international ltd. 6988 venture st., delta, bc canada, v4g 1h4 918-739b hi200 wood cast insert 10/18/11 owner's & installation manual tested by: installer : please complete the details on the back cover and leave this manual with the homeowner. Homeowner: please keep these ins...

  • Page 2

    2 hi200 hampton wood cast insert thank-you for purchasing a hampton fireplace product . The pride of workmanship that goes into each of our products will give you years of trouble-free enjoy- ment. Should you have any questions about your product that are not covered in this manual, please contact t...

  • Page 3: Table of Contents

    Hi200 hampton wood cast insert 33 table of contents safety label copy of safety label .....................................................4 dimensions unit dimensions ............................................................5 standard flue adaptor....................................................

  • Page 4: Safety Label

    4 hi200 hampton wood cast insert safety label this is a copy of the label that accompanies each hi200 wood insert . We have printed a copy of the contents here for your review. Part #: 918-740 colour: black on grey , except for selected items which are printed red. Size: 15.75" w x 2" h (file at 100...

  • Page 5: Dimensions

    Hi200 hampton wood cast insert 5 dimensions 21-1/4” 39-13/16” 2-7/8” 38-5/16” 27-1/4 ” 19-9/16 ” 4-9/16 ” 15-1/16 ” 6-3/8 ” 9-5/8 ” 24” door width 19 ” to top of door 25” note: before assembling your insert, use these dimensions to en- sure appropriate clearances will be met (refer to masonry and fa...

  • Page 6: Dimensions

    6 hi200 hampton wood cast insert dimensions unit dimensions with offset flue adaptor 21-1/4” 39-13/16” 2-7/8” 38-5/16” 17-1 1/16 ” 27-1/4 ” 19-9/16 ” 4-9/16 ” 15-1/16 ” 6-3/8 ” 14-1/8 ” 25” note: before assembling your insert, use these dimensions to en- sure appropriate clearances will be met (refe...

  • Page 7: Installation

    Hi200 hampton wood cast insert 7 installation chimney specifications before installing, check and clean your chimney system thoroughly. If in doubt about its condi- tion, seek professional advice. Your hampton insert is designed for installation into a masonry fireplace that is constructed in accord...

  • Page 8: Installation

    8 hi200 hampton wood cast insert installation clearance diagram for installations side and top facing is a maximum of 1.5" thick. Floor protection must non-combustible, insulative material with an r value of 1.1 or greater. * if the hearth extension is flush with the floor (f) it must extend 19.5" i...

  • Page 9: Installation

    Hi200 hampton wood cast insert 9 installation note: you will be required to purchase either the standard or offset 6" diameter (152mm) flue adaptor that is best suited for the specific installation. List of tools needed; - pull rod (included with insert) - 1/2” socket / ratchet - 3/8 open face wrenc...

  • Page 10: Installation

    10 hi200 hampton wood cast insert installation 6) install the unit by first setting the rear of the unit into the fireplace. See diagram 3. Ensure that the unit is centered in the existing fireplace and lined up with the flue adaptor. 7) slide the unit back until the flue adaptor is slightly engaged...

  • Page 11: Installation

    Hi200 hampton wood cast insert 11 installation 1) positive flue connection with cleanout 2) direct flue connection with cleanout 3a) full flue liner (no cleanout required) note: a clean-out door is sometimes required, by your inspector, to be installed when either the positive flue connection or dir...

  • Page 12: Installation

    12 hi200 hampton wood cast insert installation fan & cast faceplate installation 918-745b 02/19/09 1 hi200 fan & cast faceplate installation stop! Read carefully. Enamel & cast components are very fragile. Use extreme care when handling. Note: the liner and fl ue adaptor should be installed prior to...

  • Page 13: Installation

    Hi200 hampton wood cast insert 13 installation 918-745b 02/19/09 2 hi200 6) place ashlip over fan by fi tting it onto the fl ange on the fi rebox. See diagram 5 and 6. Diagram 5 diagram 6 ashlip diagram 7 do not route the fan power cord under or in front of the unit. Do not turn the fan on until you...

  • Page 14: Installation

    14 hi200 hampton wood cast insert installation brick flue baffle & secondary air tube installation the flue baffle system located in the upper area of the firebox is removable to make cleaning your chimney system easier. The brick baffles must be installed prior to your first fire. Smoke spillage an...

  • Page 15: Installation

    Hi200 hampton wood cast insert 15 15 installation operating instructions first fire when your installation is completed and in- spected, you are ready for your first fire. 1) open draft control fully. 2) open firebox door and build a small fire using paper and dry kindling, wait a few minutes for a ...

  • Page 16: Operating Instructions

    16 hi200 hampton wood cast insert 16 operating instructions 8) do not permit creosote or soot buildup in the chimney system. Check and clean chimney at regular intervals. 9) your hampton insert can be very hot. You may be seriously burned if you touch the insert while it is operating. Warn children ...

  • Page 17: Maintenance

    Hi200 hampton wood cast insert 17 maintenance door gasket if the door gasket requires replacement, 7/8" diameter material must be used. A proper high temperature gasket adhesive is required. A gasket repair kit, part # 846-570 is available from your local hampton dealer. Glass cleaning only clean yo...

  • Page 18: Maintenance

    18 hi200 hampton wood cast insert maintenance handle replacement 1) remove handle by undoing the hex head bolt using a 7/16" socket wrench. 2) fit new door handle over door latch and secure. Assemble handle by: a) placing lock washer and split lock washer over hex head bolt. B) place hex head bolt i...

  • Page 19: Maintenance

    Hi200 hampton wood cast insert 19 maintenance latch adjustment the door latch or door alignment may require adjustment as the door gasket material compresses after a few fires. Removal of spacers will allow the latch to be moved closer to the door frame, causing a tighter seal and the ability to rai...

  • Page 20: Maintenance

    20 hi200 hampton wood cast insert maintenance annual maintenance completely clean out entire unit annually inspect air tubes, baffles and bricks replace any damaged parts. Adjust door catch / latch if unable to obtain a tight seal on the door - replace door gasket seal. Readjust latch after new gask...

  • Page 21: Parts List

    Hi200 hampton wood cast insert 21 parts list main assembly part # description 1) 948-163 cane bolt latch 2) 940-356/p glass - replacement 3) 948-467 hinge pin lower 4) 936-238 adhesive tape gasket 5) 210-554 glass retainer clips / screws (set of 4) 6) * screws - 10-24 x 3/8" 9) 210-550 door handle a...

  • Page 22: Parts List

    22 hi200 hampton wood cast insert parts list cast faceplate part # description 210-921 metallic black faceplate 210-925 timberline brown faceplate 1) * top surround 2) * left side surround 3) * right side faceplate * not available as a replacement part. Firebrick part # description 170-960 complete ...

  • Page 23: Warranty

    Hi200 hampton wood cast insert 23 warranty warranty revised: 01-04-07 for models: h300 hi300 h200 hampton fireplace products are designed with reliability and simplicity in mind. In addition, our internal quality assurance team carefully inspects each unit thoroughly before it leaves our facility. F...

  • Page 24: Register Your Regency

    Printed in canada © copyright 2011, fpi fireplace products international ltd. All rights reserved. Installer: please complete the following information dealer name & address: ______________________________________________ ___________________________________________________________________ installer:...