FPI Regency P36D-LP1 Owners & Installation Manual - Regency™ Series Options

Other manuals for Regency P36D-LP1: Owners & Installation Manual, Owners & Installation Manual
Manual is about: Direct Vent Gas Fireplace

Summary of Regency P36D-LP1

  • Page 1

    Fpi fireplace products international ltd. 6988 venture st., delta, bc canada, v4g 1h4 918-522b 09/02/08 p36d-1 zero clearance direct vent gas fireplace owners & installation manual tested by: installer : please complete the details on the back cover and leave this manual with the homeowner. Homeowne...

  • Page 2

    Fpi p36d-1 zero clearance direct vent gas fireplace 2 to the new owner: congratulations! You are the owner of a state-of-the-art gas fireplace by fpi fireplace products international ltd. The p36d-1 is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a w...

  • Page 3: Table of Contents

    Fpi p36d-1 zero clearance direct vent gas fireplace 3 table of contents 4” x 6-5/8” rigid pipe cross reference chart .............22 rigid pipe venting systems .................................24 venting arrangements horizontal termination ............25 venting arrangements vertical termination ......

  • Page 4: Table of Contents

    Fpi p36d-1 zero clearance direct vent gas fireplace 4 table of contents operating instructions operating instructions .................................................49 shutdown procedure ...................................................49 first fire .................................................

  • Page 5: Safety Label

    Fpi p36d-1 zero clearance direct vent gas fireplace 5 this is a copy of the label that accompanies each p36d-1 zero clearance direct vent gas fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, visible when the bot...

  • Page 6: Requirements

    Fpi p36d-1 zero clearance direct vent gas fireplace 6 requirements 5.08: modifications to nfpa-54, chapter 10 (2) revise 10.8.3 by adding the following additional requirements: (a) for all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in w...

  • Page 7: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 7 36" (914mm) 33"(838mm) installation 36"(914mm) 30-1/2"(775mm) 37"(940mm) 17-1/8"(435mm) 32-1/2"(826mm) 37"(940mm) unit dimensions.

  • Page 8: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 8 installation important message save these instructions the p36d-ng1 or p36d-lp1 direct vent fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the "authority havin...

  • Page 9: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 9 installation diagram 1 this includes: 1) clocking the appliance to ensure the correct fi ring rate (rate noted on label 30,000 btu/h) after burning appliance for 15 minutes. 2) if required, adjusting the primary air to ensure that the fl ame does...

  • Page 10: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 10 installation the heatwave duct kit and the heat release kit have different clearance and framing requirements, check the heatwave and heat release manual for details. Heat release kit the clearances listed below are minimum distances unless othe...

  • Page 11: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 11 installation clearances for bay front, flush front & full screen doors clearances for barcelona front regency ® clearances clearances for the balmoral front clearances for the kensington ® front hampton ® clearances tripoli arch door clearances.

  • Page 12: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 12 because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in diagrams 1, 2, & 3. Regency ® combustible mantel clearances these drawings are to scale at 1:6 (on...

  • Page 13: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 13 regency ® series combustible mantel clearances because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in the diagram below. Note: a non-combustible mantel m...

  • Page 14: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 14 these drawings are to scale at 1:6 (one inch = 6 inches) mantel can be installed anywhere in shaded area or higher using the above scale. Note: ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may disco...

  • Page 15: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 15 these drawings are to scale at 1:6 (one inch = 6 inches) mantel can be installed anywhere in shaded area or higher using the above scale. Note: ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may disco...

  • Page 16: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 16 installation regency ® mantel leg clearances combustible mantel leg clearances as per diagram: maximum 1-1/2" projection at 2" minimum clearance. Hampton ® & barcelona trim mantel leg clearances combustible mantel leg clearances as per diagram: ...

  • Page 17: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 17 framing dimensions a b c d 36-1/4" 37-1/4" 17-3/8" 46-1/2"* 921mm 946mm 441mm 1181mm* * 'd' is minimum height to combustible materials including the minimum 2-1/2" (64mm) top clearance to the horizontal vent. 1) determine the total thickness of ...

  • Page 18: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 18 steel stud steel stud min. 12" (305mm) min. 6" (153mm) min. 6" (153mm) 37-1/4" (946mm) 30-1/2" (775mm) 36-1/4" (921mm) front framing dimensions using the barcelona series option non-combustible material when installing the optional barcelona fro...

  • Page 19: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 19 "c" screw position: for a facing material depth of 1-1/4" (32mm), the top facing support must be reversed. Unit assembly prior to installation the top facing support, the side nailing strips and the 2 top standoffs must be correctly positioned a...

  • Page 20: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 20 exterior vent termination locations a= clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) b= clearance to window or door that may be opened *(12"/30cm) c= clearance to permanently closed window *(min. 12"/30cm) d= v ertical...

  • Page 21: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 21 venting direct vent system (flex) horizontal terminations only these venting systems, in combination with the p36d-1 direct vent gas fireplace, have been tested and listed as a direct vent heater system by warnock hersey. The location of the ter...

  • Page 22: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 22 installation 4” x 6-5/8” rigid pipe cross reference chart components from different manufacturers may not be mixed. Not all rigid pipe components are available directly from fpi. Description simpson direct vent pro ® simpson direct vent gs ® dis...

  • Page 23: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 23 description simpson direct vent pro ® simpson direct vent gs ® discontinued selkirk direct-temp™ american metal products ® amerivent direct metal-fab ® sure seal security secure vent ® attic insulation shield 12” 46dva-is - n/a from fpi n/a n/a ...

  • Page 24: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 24 rigid pipe adaptor pipe length vertical termination cap storm collar flashing ceiling firestop 24" pipe length adj.Pipe length 11" - 14-5/8" 90 elbow o horizontal termination cap wall thimble vinyl siding standoff (optional) rigid pipe venting s...

  • Page 25: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 25 installation venting arrangements horizontal termination rigid pipe and fpi direct vent system (flex) (propane & natural gas) the diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 o elbow (two 4...

  • Page 26: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 26 installation • vent must be supported at offsets. • firestops are required at each fl oor level and whenever passing through a wall. • maintain clearances to combustibles. Note: must use optional rigid pipe adaptor when using rigid vent systems ...

  • Page 27: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 27 the p36d-1 is approved for a 40 ft. Straight vertical, with rigid pipe vent systems for propane and natural gas, as per the diagram 1. The shaded area in the diagram 1 shows all allowable combinations of straight vertical and offset to vertical ...

  • Page 28: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 28 installation horizontal venting with two (2) 90 o elbows horizontal venting with three (3) 90 o elbows h h1 v option v h + h1 a) 0' min. 2' max. B) 1' min. 3' max. C) 2' min. 4' max. D) 3' min. 5' max. E) 4' min. 6' max. F) 5' min. 7' max. G) 6'...

  • Page 29: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 29 v h1 h v1 installation vertical venting with two (2) 90 o elbows vertical venting with three (3) 90 o elbows v1 v h option v h v + v1 a) 0' min. 2' max. 1' min. B) 1' min. 4' max. 3' min. C) 2' min. 5' max. 4' min. D) 3' min. 6' max. 5' min. E) ...

  • Page 30: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 30 installation vertical termination with co-linear flex system the appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance. This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl...

  • Page 31: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 31 installation venting arrangement - vertical terminations co-linear flex system into masonry fireplaces for both residential & manufactured homes the shaded area in the diagrams show the allowable vertical terminations. 8' min. 40-1/2” 30' max. 3...

  • Page 32: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 32 diagram 4 6) the arrow on the vent cap should be pointing up. Insure that the 1-1/2" clearances to combustible materials are maintained (diagram 4). Install the termination cap. Note: for snorkel terminations in above grade installations, follow...

  • Page 33: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 33 installation diagram 3 diagram 5 diagram 1 diagram 2 note: for best results and optimum performance with each approved venting system, it is highly recommended to apply “mill-pac” sealant (supplied) to every in- ner pipe connection. Failure to d...

  • Page 34: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 34 4) separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall. The thimble halves slip inside each oth...

  • Page 35: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 35 installation gas pipe pressure testing the appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or les...

  • Page 36: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 36 installation this conversion must be done by a qualified gas fitter if in doubt do not do this conversion !! 1) shut off the gas supply. 2) remove the louvers (and bay door if it is installed). 3) open the fl ush door and remove the door. 4) rem...

  • Page 37: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 37 installation installation of the dc sparker: 16) verify that if the conversion is from ng to lpg, the screw must be re- assembled with the red o-ring visible (fig. 5). Lpg configuration red o-ring visible fig.5 17) re-assemble the black protecti...

  • Page 38: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 38 installation 27) run the other end of the ground wire and dc spark generator wires through the bushing on the heat shield. 29) plug the dc spark generator wires to the dc sparker. 30) connect the ground wire to the dc sparker mounting bracket. H...

  • Page 39: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 39 installation 1) undo the bottom 2 door latches and open and remove glass door. Remove logs. Note: the logs must not be in the unit. 2) insert the back brick panel fi rst by carefully slipping it between the back wall of the fi rebox and the rear...

  • Page 40: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 40 installation log set installation notch bracket bracket 02-51 02-75 02-51 3) place the log 02-75 on the rear log support pins with the fl at side to the back. 1) carefully remove the logs from the box and unwrap them. The logs are fragile, handl...

  • Page 41: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 41 rear bracket 02-55 02-75 02-53 7) place the bottom left front edge of log 02-55 against the rear bracket on the burner tray and rest the log on the cutout on log 02-53. Cutouts 5th grate tab 02-54 02-53 02-51 6) position log 02-54 across the cut...

  • Page 42: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 42 log indentation photo shows rear grate tab. Log 02-51 was removed to show the positioning of log 02-52. Rear grate tab 02-52 02-51 02-54 02-52 02-54 8) place log 02-52 between logs 02-51 and 02-75 and on the indentation on log 02-54. The bottom ...

  • Page 43: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 43 place embers in these 3 locations on the burner tray. 02-50 02-55 02-75 02-53 02-51 02-54 02-52 10) place the embers on the front of the burner tray in the places shown on the photos below. Separate platinum embers and place on the front burner ...

  • Page 44: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 44 diagram 3 use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket. Repeat for 2nd spring. See diagram 3. Diagram 2 the standard fl ush door comes with a black frame. To install the frame, simply ho...

  • Page 45: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 45 14 ga. 16 ga. 18 ga. 20 ga. 22 ga. 50 ft. 32 ft. 20 ft. 12 ft. 9 ft. Recommended maximum lead length (two-wire) when using wall thermostat (cp-2 system) wire size max. Length thermostat wire table wall thermostat (optional) a wall thermostat may...

  • Page 46: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 46 wiring diagrams caution: ensure that the wires do not touch any hot surfaces and are away from sharp edges. This heater does not require a 120v a.C. Sup- ply for operation. In case of a power failure, the burner switch and the optional remote co...

  • Page 47: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 47 for propane units and units equipped with dc spark boxes* *for installation of the dc spark box refer to the lp conversion instructions in this manual. Installation.

  • Page 48: Installation

    Fpi p36d-1 zero clearance direct vent gas fireplace 48 optional fan installation 120 volt ac power is needed for the fan switch and blower. The fan can be hard wired if desired. The receptacle box should be installed on the left hand side of the unit by a quali fi ed electrician. The neutral (wider)...

  • Page 49: Operating Instructions

    Fpi p36d-1 zero clearance direct vent gas fireplace 49 operating instructions important gas on/off knob cannot be turned from "pilot" to "off" unless it is partially depressed. 1) turn burner off using "on/off" switch. 2) turn gas control knob so indicator points to "off" position and allow 5 minute...

  • Page 50: Maintenance

    Fpi p36d-1 zero clearance direct vent gas fireplace 50 maintenance instructions 1) always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use ...

  • Page 51: Maintenance

    Fpi p36d-1 zero clearance direct vent gas fireplace 51 maintenance note: never operate the appliance without the glass properly secured in place. 6) do not use this appliance if any part has been under water. Immediately call a quali fi ed service technician to inspect the appliance and to replace n...

  • Page 52: Maintenance

    Fpi p36d-1 zero clearance direct vent gas fireplace 52 11) undo the pilot tube from the valve with a 7/16" wrench. 12) undo the quick drop out thermocouple nut on the valve with a 9mm (metric) wrench. 13) remove the piezo igniter wire and push button assembly. 14) undo the "gas out" fl are nut with ...

  • Page 53: Regency

    Fpi p36d-1 zero clearance direct vent gas fireplace 53 flush louvers 1) install the top louver by sliding the two bracket clips into the brackets located underneath the top of the fi rebox. 2) the bottom louver has a hinge that is attached (2 screws per hinge) to the lip on bottom of the unit. 3) op...

  • Page 54: Regency

    Fpi p36d-1 zero clearance direct vent gas fireplace 54 regency ® options bay trim attach supplied magnets each to the back of the top and bottom trim pieces, and attach trim to the top and bottom of bay door. 4) open the bottom louver. Pull the burner on/off control box from inside the bottom of the...

  • Page 55: Regency

    Fpi p36d-1 zero clearance direct vent gas fireplace 55 regency ® options full screen door installation 1) before beginning the installation, remove the screen doors from the full screen door frame by fully opening the doors and lifting up off of the hinges. See important note in step 7. Inner cut-ou...

  • Page 56: Regency

    Fpi p36d-1 zero clearance direct vent gas fireplace 56 regency ® options 3) install the hinges to the hinge brackets on the left and right side of the bottom of the outer frame, secure using 2 x #8 philips head screws per hinge. 4) place the bottom grill near hinge. Flip the hinge over the bottom gr...

  • Page 57: Regency

    Fpi p36d-1 zero clearance direct vent gas fireplace 57 regency ® options when installing the optional tripoli screen door series, a non-combustible material 12" (305mm) above the unit and 6" (153mm) on each side must be used (see diagram 1). The tripoli screen door series also requires steel stud fr...

  • Page 58: Regency

    Fpi p36d-1 zero clearance direct vent gas fireplace 58 regency ® options note: the facing material has to go on after the unit is set. 1) remove glass door. Refer to p36 manual. 2) remove 2 screws and bracket as indicated (refer to diagram 2). 3) install on/off switch (refer to diagram 3). 4) place ...

  • Page 59: Regency

    Fpi p36d-1 zero clearance direct vent gas fireplace 59 note: the nailing strips can be adjusted, depending on the fac material (as indicated in diagram 7). 9) optional install optional 3-panel arch door. (refer to install 3-panel a door instruction sheet). 8) attach top and side support frame a) ens...

  • Page 60: Regency™ Series Options

    Fpi p36d-1 zero clearance direct vent gas fireplace 60 regency™ series options the kensington ® front installation 1) bend tabs downwards located at the back of the kensington ® front. Bend tabs downwards. Backside of front shown. 2) secure the bottom frame of the front by loosening the inner screw ...

  • Page 61: Regency™ Series Options

    Fpi p36d-1 zero clearance direct vent gas fireplace 61 regency™ series options the balmoral ® front installation 6) for optional fan installation, see "optional fan installation" section. 7) for 2-panel & 3-panel door installation, see "2-panel door installation & 3-panel door installation" sections...

  • Page 62: Regency™ Series Options

    Fpi p36d-1 zero clearance direct vent gas fireplace 62 the kensington ® & balmoral front 2-panel door installation 3-panel door installation regency™ series options 2) mount 3-panel door frame to fl ange on sub-frame, ensuring to line-up holes. Secure using the 4 screws provided. Secure bottom of su...

  • Page 63: Regency™ Series Options

    Fpi p36d-1 zero clearance direct vent gas fireplace 63 the kensington, balmoral front optional fan installation 1) remove fan cover by undoing screw. 2) disconnect fan switch wires and discard fan cover with wires. Fan cover 3) connect new fan control box wires to the existing fan plug wires (red to...

  • Page 64: Hampton

    Fpi p36d-1 zero clearance direct vent gas fireplace 64 hampton ® options hampton ® cast faceplate 1) remove top louver and grill. 2) open bottom louver and grill. 3) install the left side faceplate by pushing in at the side of the fi rebox and line up with top and bottom holes on side. Secure with s...

  • Page 65: Hampton

    Fpi p36d-1 zero clearance direct vent gas fireplace 65 1) remove the 3 faceplate mounting phillips head screws from the inside top of fi rebox, and discard if necessary. 2) place top grill in brackets located inside top of fi rebox as shown. 3) remove hinge brackets on bottom left and right side of ...

  • Page 66: Parts List

    Fpi p36d-1 zero clearance direct vent gas fireplace 66 parts list main assembly part # description part # description part # description 1) 948-253 door handle 2) 510-026 hinge bracket - left/right 3) 948-045 chain 4) 948-115 spring 6) 430-129 receptacle box mount 7) 910-429 box - receptacle 8) 910-...

  • Page 67: Parts List

    Fpi p36d-1 zero clearance direct vent gas fireplace 67 burner assembly & log set part # description 52) 910-190 piezo ignitor & nut 53) 780-021 gasket - valve access plate ng/lp 54) 910-421 pilot on/off 3" extension knob 55) 910-422 flame hi/low 3" extension knob 780-574/p valve assy - natural gas 7...

  • Page 68: Parts List

    Fpi p36d-1 zero clearance direct vent gas fireplace 68 parts list regency ® bay front assembly part # description part # description 780-931 bay front complete 103) 940-092/p side glass 107) 936-243 glass gasket 108) 940-094/p center glass 112) * bay front trim - top/bottom 780-934 bay front trim (s...

  • Page 69: Parts List

    Fpi p36d-1 zero clearance direct vent gas fireplace 69 parts list regency ® flush front assembly part # description part # description 132) 512-518 flush door assembly 135) 940-090/p glass (flush) 136) 936-155 glass gasket (tadpole) 904-691 u-clip 510-920 flush louvers (set)-gold/blk 510-921 flush l...

  • Page 70: Parts List

    Fpi p36d-1 zero clearance direct vent gas fireplace 70 parts list hampton ® cast faceplate & grill assembly part # description 513-971** cast faceplate (set) 201) * cast faceplate - right 202) * cast faceplate - top 203) * cast faceplate - left 513-981** cast grills (set) 204) * top grill 205) * bot...

  • Page 71: Warranty

    Fpi p36d-1 zero clearance direct vent gas fireplace 71 warranty regency fireplace products are designed with reliability and simplicity in mind. In addition, our internal quality assurance team carefully inspects each unit thoroughly before it leaves our facility. Fpi fireplace products internationa...

  • Page 72: Fpi

    Fpi p36d-1 zero clearance direct vent gas fireplace 72 installer: please complete the following information dealer name & address: ______________________________________________ ___________________________________________________________________ installer: ___________________________________________...