  • Page 1

    Fpi fireplace products international ltd. 6988 venture st., delta, bc canada, v4g 1h4 918-522c 04/08/13 p36d-1 zero clearance direct vent gas fireplace owners & installation manual tested by: installer: please complete the details on the back cover and leave this manual with the homeowner. Homeowner...

  • Page 2

    2 regency ® p36d-1 zero clearance direct vent gas fireplace to the new owner: congratulations! You are the owner of a state-of-the-art gas fireplace by regency ® fireplace prod- ucts the p36d-1 is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood f...

  • Page 3

    Regency ® p36d-1 zero clearance direct vent gas fireplace 3 information for mobile/manufactured homes after first sale this regency ® product has been tested and listed by warnock hersey to the following standards: vented gas fireplace heaters ansi z21.88a-2007/ csa 2.33a-2007 and gas-fired applianc...

  • Page 4: Table of Contents

    4 regency ® p36d-1 zero clearance direct vent gas fireplace table of contents vertical termination .....................................................26 horizontal venting with two (2) 90 o elbows ................28 horizontal venting with three (3) 90 o elbows .............28 vertical venting wit...

  • Page 5: Table of Contents

    Regency ® p36d-1 zero clearance direct vent gas fireplace 5 5 table of contents operating instructions operating instructions .................................................49 shutdown procedure ..................................................49 first fire ..........................................

  • Page 6: Safety Label

    6 regency ® p36d-1 zero clearance direct vent gas fireplace safety label this is a copy of the label that accompanies each p36d-1 zero clearance direct vent gas fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, v...

  • Page 7: Requirements

    Regency ® p36d-1 zero clearance direct vent gas fireplace 7 requirements 5.08: modifications to nfpa-54, chapter 10 (2) revise 10.8.3 by adding the following additional requirements: (a) for all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure use...

  • Page 8: Installation

    8 regency ® p36d-1 zero clearance direct vent gas fireplace installation 36" (914mm) 33"(838mm) 36"(914mm) 30-1/2"(775mm) 37"(940mm) 17-1/8"(435mm) 32-1/2"(826mm) 37"(940mm) unit dimensions.

  • Page 9: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 9 installation clothing or other flammable material should not be placed on or near the appliance. Children and adults should be alerted to the hazards of high surface temperatures, espe- cially the fireplace glass, and should stay away to av...

  • Page 10: Installation

    10 regency ® p36d-1 zero clearance direct vent gas fireplace installation important message save these instructions the p36d-ng1 or p36d-lp1 direct vent fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the "authorit...

  • Page 11: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 11 installation diagram 1 this includes: 1) clocking the appliance to ensure the correct fi ring rate (rate noted on label 30,000 btu/h) after burning appliance for 15 minutes. 2) if required, adjusting the primary air to ensure that the fl a...

  • Page 12: Installation

    12 regency ® p36d-1 zero clearance direct vent gas fireplace installation the heatwave duct kit and the heat release kit have different clearance and framing requirements, check the heatwave and heat release manual for details. Heat release kit the clearances listed below are minimum distances unles...

  • Page 13: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 13 installation clearances for flush front & full screen doors regency ® clearances tripoli arch door clearances.

  • Page 14: Installation

    14 regency ® p36d-1 zero clearance direct vent gas fireplace installation drywall 12" mantel 7 1/2" mantel 3 1/2" mantel mantel clearances with flush glass / full screen doors 14" 7" 10" 30-1/2" to floor 2 0 12 6 4 8 10 2 0 12 6 16 4 14 8 10 side view top of unit 6" standof f because of the extreme ...

  • Page 15: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 15 installation regency ® series combustible mantel clearances because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in the diagram below. Note: a non-c...

  • Page 16: Installation

    16 regency ® p36d-1 zero clearance direct vent gas fireplace installation regency ® mantel leg clearances combustible mantel leg clearances as per diagram: maximum 1-1/2" projection at 2" minimum clearance..

  • Page 17: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 17 installation framing dimensions a b c d 36-1/4" 37-1/4" 17-3/8" 46-1/2"* 921mm 946mm 441mm 1181mm* * 'd' is minimum height to combustible materials including the minimum 2-1/2" (64mm) top clearance to the horizontal vent. 1) determine the ...

  • Page 18: Installation

    18 regency ® p36d-1 zero clearance direct vent gas fireplace installation when installing the optional tripoli arch door, a non-combustible material 12" (305mm) above the unit and 6" (153mm) on each side must be used. See diagram 2. For complete framing dimensions - see instructions in this manual. ...

  • Page 19: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 19 installation side nailing strips "c" screw position: for a facing material depth of 1-1/4" (32mm), the top facing support must be reversed. Unit assembly prior to installation the top facing support, the side nailing strips and the 2 top s...

  • Page 20: Installation

    20 regency ® p36d-1 zero clearance direct vent gas fireplace installation exterior vent termination locations minimum clearance requirements canada 1 usa 2 a clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm) b clearance to window or door that may be opened 12"(30cm) 9" (23c...

  • Page 21: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 21 installation venting direct vent system (flex) horizontal terminations only these venting systems, in combination with the p36d-1 direct vent gas fireplace, have been tested and listed as a direct vent heater system by warnock hersey. The ...

  • Page 22: Installation

    22 regency ® p36d-1 zero clearance direct vent gas fireplace installation 4” x 6-5/8” rigid pipe cross reference chart components from different manufacturers may not be mixed. Not all rigid pipe components are available directly from fpi. Description simpson direct vent pro ® selkirk direct temp™ a...

  • Page 23: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 23 installation description simpson direct vent pro ® selkirk direct temp™ american metal products® amerivent direct metal-fab™ sure seal security secure- vent® icc excel direct attic insulation shield 12” 46dva-is n/a@ fpi n/a 4dais12 n/a sv...

  • Page 24: Installation

    24 regency ® p36d-1 zero clearance direct vent gas fireplace installation rigid pipe adaptor pipe length vertical termination cap storm collar flashing ceiling firestop 24" pipe length adj.Pipe length 11" - 14-5/8" 90 elbow o horizontal termination cap wall thimble vinyl siding standoff (optional) r...

  • Page 25: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 25 installation venting arrangements horizontal termination rigid pipe and fpi direct vent system (flex) (propane & natural gas) the diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 o elbow ...

  • Page 26: Installation

    26 regency ® p36d-1 zero clearance direct vent gas fireplace installation • vent must be supported at offsets. • firestops are required at each fl oor level and whenever passing through a wall. • maintain clearances to combustibles. Note: must use optional rigid pipe adaptor when using rigid vent sy...

  • Page 27: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 27 installation the p36d-1 is approved for a 40 ft. Straight vertical, with rigid pipe vent systems for propane and natural gas, as per the diagram 1. The shaded area in the diagram 1 shows all allowable combinations of straight vertical and ...

  • Page 28: Installation

    28 regency ® p36d-1 zero clearance direct vent gas fireplace installation horizontal venting with two (2) 90 o elbows horizontal venting with three (3) 90 o elbows h h1 v option v h + h1 a) 0' min. 2' max. B) 1' min. 3' max. C) 2' min. 4' max. D) 3' min. 5' max. E) 4' min. 6' max. F) 5' min. 7' max....

  • Page 29: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 29 installation v h1 h v1 vertical venting with two (2) 90 o elbows vertical venting with three (3) 90 o elbows v1 v h option v h v + v1 a) 0' min. 2' max. 1' min. B) 1' min. 4' max. 3' min. C) 2' min. 5' max. 4' min. D) 3' min. 6' max. 5' mi...

  • Page 30: Installation

    30 regency ® p36d-1 zero clearance direct vent gas fireplace installation vertical termination with co-linear flex system the appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance. This appliance is designed to be attached to two 3" (76mm) co-linear alumin...

  • Page 31: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 31 installation venting arrangement - vertical terminations co-linear flex system into masonry fireplaces for both residential & manufactured homes the shaded area in the diagrams show the allowable vertical terminations. 8' min. 40-1/2” 30' ...

  • Page 32: Installation

    32 regency ® p36d-1 zero clearance direct vent gas fireplace installation diagram 4 6) the arrow on the vent cap should be pointing up. Insure that the 1-1/2" clearances to combustible materials are maintained (diagram 4). Install the termination cap. Note: for snorkel terminations in above grade in...

  • Page 33: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 33 installation diagram 3 diagram 5 diagram 1 diagram 2 note: for best results and optimum performance with each approved venting system, it is highly recommended to apply “mill-pac” sealant (supplied) to every inner pipe connection. Failure ...

  • Page 34: Installation

    34 regency ® p36d-1 zero clearance direct vent gas fireplace installation 4) separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall. The thimble halves s...

  • Page 35: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 35 installation gas pipe pressure testing the appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to ...

  • Page 36: Installation

    36 regency ® p36d-1 zero clearance direct vent gas fireplace installation this conversion must be done by a qualified gas fitter if in doubt do not do this conversion !! 1) shut off the gas supply. 2) remove the louvers (and bay door if it is installed). 3) open the fl ush door and remove the door. ...

  • Page 37: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 37 installation installation of the dc sparker: 16) verify that if the conversion is from ng to lpg, the screw must be re- assembled with the red o-ring visible (fig. 5). Lpg configuration red o-ring visible fig.5 17) re-assemble the black pr...

  • Page 38: Installation

    38 regency ® p36d-1 zero clearance direct vent gas fireplace installation 27) run the other end of the ground wire and dc spark generator wires through the bushing on the heat shield. 29) plug the dc spark generator wires to the dc sparker. 30) connect the ground wire to the dc sparker mounting brac...

  • Page 39: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 39 installation 1) undo the bottom 2 door latches and open and remove glass door. Remove logs. Note: the logs must not be in the unit. 2) insert the back brick panel fi rst by carefully slipping it between the back wall of the fi rebox and th...

  • Page 40: Installation

    40 regency ® p36d-1 zero clearance direct vent gas fireplace installation notch bracket bracket 02-51 02-75 02-51 3) place the log 02-75 on the rear log support pins with the fl at side to the back. 1) carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - d...

  • Page 41: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 41 installation log set installation rear bracket 02-55 02-75 02-53 7) place the bottom left front edge of log 02-55 against the rear bracket on the burner tray and rest the log on the cutout on log 02-53. Cutouts 5th grate tab 02-54 02-53 02...

  • Page 42: Installation

    42 regency ® p36d-1 zero clearance direct vent gas fireplace installation log indentation photo shows rear grate tab. Log 02-51 was removed to show the positioning of log 02-52. Rear grate tab 02-52 02-51 02-54 02-52 02-54 8) place log 02-52 between logs 02-51 and 02-75 and on the indentation on log...

  • Page 43: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 43 installation place embers in these 3 locations on the burner tray. 02-50 02-55 02-75 02-53 02-51 02-54 02-52 10) place the embers on the front of the burner tray in the places shown on the photos below. Separate platinum embers and place o...

  • Page 44: Installation

    44 regency ® p36d-1 zero clearance direct vent gas fireplace installation diagram 3 use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket. Repeat for 2nd spring. See diagram 3. Diagram 2 the standard fl ush door comes with a black frame. To install t...

  • Page 45: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 45 installation 14 ga. 16 ga. 18 ga. 20 ga. 22 ga. 50 ft. 32 ft. 20 ft. 12 ft. 9 ft. Recommended maximum lead length (two-wire) when using wall thermostat (cp-2 system) wire size max. Length thermostat wire table wall thermostat (optional) a ...

  • Page 46: Installation

    46 regency ® p36d-1 zero clearance direct vent gas fireplace installation wiring diagrams caution: ensure that the wires do not touch any hot surfaces and are away from sharp edges. This heater does not require a 120v a.C. Sup- ply for operation. In case of a power failure, the burner switch and the...

  • Page 47: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 47 installation for propane units and units equipped with dc spark boxes* *for installation of the dc spark box refer to the lp conversion instructions in this manual..

  • Page 48: Installation

    48 regency ® p36d-1 zero clearance direct vent gas fireplace installation optional fan installation 120 volt ac power is needed for the fan switch and blower. The fan can be hard wired if desired. The receptacle box should be installed on the left hand side of the unit by a qualifi ed electrician. T...

  • Page 49: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 49 49 installation operating instructions important gas on/off knob cannot be turned from "pilot" to "off" unless it is partially depressed. 1) turn burner off using "on/off" switch. 2) turn gas control knob so indicator points to "off" posit...

  • Page 50: Operating Instructions

    50 regency ® p36d-1 zero clearance direct vent gas fireplace 50 operating instructions maintenance instructions 1) always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a ye...

  • Page 51: Maintenance

    Regency ® p36d-1 zero clearance direct vent gas fireplace 51 maintenance note: never operate the appliance without the glass properly secured in place. 6) do not use this appliance if any part has been under water. Immediately call a qualifi ed service technician to inspect the appliance and to repl...

  • Page 52: Maintenance

    52 regency ® p36d-1 zero clearance direct vent gas fireplace maintenance 11) undo the pilot tube from the valve with a 7/16" wrench. 12) undo the quick drop out thermocouple nut on the valve with a 9mm (metric) wrench. 13) remove the piezo igniter wire and push button assembly. 14) undo the "gas out...

  • Page 53: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 53 53 installation regency ® options flush louvers 1) install the top louver by sliding the two bracket clips into the brackets located underneath the top of the fi rebox. 2) the bottom louver has a hinge that is attached (2 screws per hinge)...

  • Page 54: Regency

    54 regency ® p36d-1 zero clearance direct vent gas fireplace 54 regency ® options full screen door installation 1) before beginning the installation, remove the screen doors from the full screen door frame by fully opening the doors and lifting up off of the hinges. See important note in step 7. Inn...

  • Page 55: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 55 55 installation regency ® options 3) install the hinges to the hinge brackets on the left and right side of the bottom of the outer frame, secure using 2 x #8 philips head screws per hinge. 4) place the bottom grill near hinge. Flip the hi...

  • Page 56: Regency

    56 regency ® p36d-1 zero clearance direct vent gas fireplace 56 regency ® options when installing the optional tripoli screen door series, a non-combustible material 12" (305mm) above the unit and 6" (153mm) on each side must be used (see diagram 1). The tripoli screen door series also requires stee...

  • Page 57: Installation

    Regency ® p36d-1 zero clearance direct vent gas fireplace 57 57 installation regency ® options note: the facing material has to go on after the unit is set. 1) remove glass door. Refer to p36 manual. 2) remove 2 screws and bracket as indicated (refer to diagram 2). 3) install on/off switch (refer to...

  • Page 58: Regency

    58 regency ® p36d-1 zero clearance direct vent gas fireplace 58 regency ® options note: the nailing strips can be adjusted, depending on the fac material (as indicated in diagram 7). 9) optional install optional 3-panel arch door. (refer to install 3-panel a door instruction sheet). 8) attach top an...

  • Page 59: Parts List

    Regency ® p36d-1 zero clearance direct vent gas fireplace 59 parts list 32 31 33 brick panel set doors & louvers please refer separate section 2 20 2 35 4 3 1 8 7 9 10 23 23 97 98 95 96 93 93 92 91 90 94 100 99 27 30 28 50 30 29 24 24 101 102 22 89 34 6 fan switch assembly 47 42 38 43 48 49 46 105 1...

  • Page 60: Parts List

    60 regency ® p36d-1 zero clearance direct vent gas fireplace parts list burner assembly & log set part # description 52) 910-190 piezo ignitor & nut 53) 780-021 gasket - valve access plate ng/lp 54) 910-421 pilot on/off 3" extension knob 55) 910-422 flame hi/low 3" extension knob 780-574/p valve ass...

  • Page 61: Parts List

    Regency ® p36d-1 zero clearance direct vent gas fireplace 61 parts list regency ® flush front assembly part # description part # description 132) 512-518 flush door assembly 135) 940-090/p glass (flush) 136) 936-155 glass gasket (tadpole) 904-691 u-clip 510-920 flush louvers (set)-gold/blk 510-921 f...

  • Page 62: Notes

    62 regency ® p36d-1 zero clearance direct vent gas fireplace notes.

  • Page 63: Warranty

    Regency ® p36d-1 zero clearance direct vent gas fireplace 63 warranty regency fireplace products are designed with reliability and simplicity in mind. In addition, our internal quality assurance team carefully inspects each unit thoroughly before it leaves our facility. Fpi fireplace products intern...

  • Page 64: Register Your Regency

    Installer: please complete the following information dealer name & address: ______________________________________________ ___________________________________________________________________ installer: ___________________________________________________________ phone #: _____________________________...