    Description of the appliance installation instructions operating instructions spare parts warranty certificate technical manual to be saved by the user for future reference document n° 759-4 en ~ 04/02/2000 les fonderies franco-belges 59660 merville phone : 03.28.43.43.43 fax : 03.28.43.43.99 rc haz...

  • Page 2

    Product information . . . . . . . . . . . . . . . . . . . . 3 package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 optional equipment . . . . . . . . . . . . . . . . . . . . . . . 3 general characteristics . . . . . . . . . . . . . . . . . . . . . 3 description . . . . . . . . . . ....

  • Page 3: 1. Product Information

    Warning to the user a wood stove should only be installed by competent personnel, in the strict application of normal practices and all safety precautions. An incorrectly installed wood stove can cause serious accidents (chimney fires, burning of plastic insulation materials, in partition walls, etc...

  • Page 4

    2. Installation instructions 2.1. The room ventilation : for satisfactory operation with a natural draught, check that sufficient air for combustion is available in the room. Chimney position : for new chimney installations, select a central position within the building, to provide a good heat distr...

  • Page 5

    2.4. Mounting the cast iron legs and the bottom heat shield remove the cast iron top from the stove (fig.2), unscrew the two bolts securing the stove to the pallet and remove the stove from the pallet. Tip the stove towards the rear and place it gently on the floor on 2 timber battens. Fix the legs ...

  • Page 6

    2.6.1. Smoke exit at rear figure 6 - lift the cast iron top from the stove (fig. 2, p. 5). - check that the two blanking plates are fixed to the cast iron top. - remove the internal baffle and the rear heat shield. - fix the sealing rope in the groove and fit the flue spigot, ensuring there is a goo...

  • Page 7: 3. Instructions For User

    2.8. Chimney maintenance and sweeping very important : to avoid any incident (chimney fire, etc.), regular maintenance should be carried out. If the stove is regularly used, the chimney should be swept several times per year, together with the stovepipe connection section. Chimney condition should b...

  • Page 8

    3.2.2. Re-fuelling • open the lower spin wheel. • open the glass door and add fuel. • leave the lower spin wheel open for a few minutes to allow the initial volatiles in the fuel to burn. • adjust the lower spin wheel to the desired position. 3.3. Control of fire the stove must operate with the door...

  • Page 9: 4. Spare Sparts

    Down draught. þ − - install an anti-down draught cowl. Consult your dealer. Room is in decompression. þ − - in houses equipped with mechanical ventilation, an outside air intake must be installed for the chimney. Low heat output. Incorrect fuels. − - use the recommended fuel. 4. Spare sparts when or...

  • Page 10

    Figure 10 document n° 759-4 en ~ 04/02/2000 ref. 134 10 09 camargue wood stove 10 technical manual.

  • Page 11

    42 307416 fuel retainer . . . . . . . . . . . . . . . . . . . . . . . . . . A . . . . . B . . . . . C . . . . . D . . . . . . . 01 43 309215 wood grate . . . . . . . . . . . . . . . . . . . . . . . . . . . A . . . . . B . . . . . C . . . . . D . . . . . . . 01 44 309859 77 front plate . . . . . . . ...

  • Page 12

    ❧ warranty certificate ❧ ❧ legal warranty our products are guaranteed for twelve months against any defect, flaw or imperfection. During this time, all parts judged defective by our warranty control department may be repla- ced in our workshops. Incidental costs of transportation and packing payable...