Franco Belges MONTFORT 134 05 01 Technical Manual

Manual is about: 5 kW

Summary of MONTFORT 134 05 01

  • Page 1

    Description of the appliance installation instructions operating instructions spare parts warranty certificate document n° 1171- ~ 20/02/2013 montfort wood stove en 13240 model : 134 05 01 output : 5 kw technical manual to be saved by the user for future reference fr en nl it parc d’activités de la ...

  • Page 2

    2 technical manual “1171” “montfort” - ref. 134 05 01 contents description of the unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P. 3 package . . . . . . . . . . . . . . . . . . P. 3 optional equipment. . . . . . . . . . . . P. 3 specifications . . . . . . . . . . . . . ....

  • Page 3: Warning

    This appliance is meant to burn wood or solid fuel safely warning incorrectly installed, this appliance can be dangerous and possibly cause serious accidents. We recommend that you engage the services of a professional engineer for its installation and the regular maintenance requirements 1. Descrip...

  • Page 4

    2. Installation instructions 2.1. Warning to the user all the local and national regulations, and in particular those relating to national and european standards, must be observed when installing the appliance. A n i n c o r r e c t l y i n s t a l l e d heating appliance can cause serious accidents...

  • Page 5

    - the chimney must be at least 4.5 m (15 ft high). - in case of a flat roof or when the roof gradient is lower than 15°, the stack must be 1,2 m (4 feet) high at least. - if the chimney has any down draught tendency, due to its position in relation to nearby obstacles, then an anti-down draught cowl...

  • Page 6

    2.5. Chimney connector - the connection to flue must be carried out according to local building regulations. - the appliance must be installed as close as possible to the chimney. - the connector pipe must be approved for installation with combustion products (either 24 ga. Black painted or blued st...

  • Page 7: 3. Instructions For User

    3. Instructions for user the manufacturer will not be responsible for damages on parts of the appliance due to the use of prohibited fuel or due to an alteration of the appliance or its installation. Only use replacement parts supplied by the manufacturer. All the local and national regulations, and...

  • Page 8

    3.2. Instructions for use with wood 3.2.1. Lighting (figure 7) • slide the secondary air inlet (# b1) to the right. Open the primary air inlet (# c1). • lay firelighters or rolled up newspapers on the grate with a reasonable quantity, if necessary, of dry kindling wood. Place 2 or 3 small logs on to...

  • Page 9

    3.4. Cleaning it is essential to keep the grate free from a heavy build up of ashes. The belfort is equipped with a grate riddling device which is used to “shake” ashes off the grate into the ash pan. Whenever the stove is burning without life when the lower spin wheel is open, use the riddling leve...

  • Page 10

    3.9. Trouble shooting problem probable causes - action fire difficult to start. Fire goes out. Wood green… or too damp - use hard wood logs, which have been cut for at least two years and stored, under a ventilated shelter. Logs are too big - to light the fire, use small, very dry twigs. To maintain...

  • Page 11: 4. Spare Parts

    4. Spare parts when ordering spare parts, specify the stove type and serial number, including the colour index (on the guarantee or identification plate), the name of the part and the part number. Example : wood stove “montfort”, ref. 134 05 01, colour c, top plate 352168 mk. Technical manual “1171”...

  • Page 12

    12 technical manual “1171” “montfort” - ref. 134 05 01 spare parts figure 10 - stove - exploded view 3 45 45.

  • Page 13

    Technical manual “1171” 13 “montfort” - ref. 134 05 01 spare parts 27 303860 mk . . . Flue collar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D . . . . . . . . . . . . . . . 01 27 303860 mp . . . Flue collar. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E ....

  • Page 14

    Guarantee certificate legal guarantee the specifications, dimensions and information shown on our documents are provided for information purposes only and under no circumstances are binding upon the vendor. With the aim of constantly improving our equipment, all modifications considered as necessary...