G&D NEO-FiberLink-2 Installation Manual

Summary of NEO-FiberLink-2

  • Page 1

    Guntermann & drunck gmbh www.Gdsys.De g&d neo-fiberlink-2 a9100163-1.10 installationsanleitung de en installation guide.

  • Page 2

    I · neo-fiberlink-2 zu dieser dokumentation diese dokumentation wurde mit größter sorgfalt erstellt und nach dem stand der technik auf korrektheit überprüft. Für die qualität, leistungsfähigkeit sowie marktgängigkeit des g&d-produkts zu einem bestimmten zweck, der von dem durch die produktbeschreibu...

  • Page 3

    Neo-fiberlink-2 · ii deutsch fcc statement the devices named in this manual comply with part 15 of the fcc rules. Opera- tion is subject to the following two conditions: (1) the devices may not cause harm- ful interference, and (2) the devices must accept any interference received, including interfe...

  • Page 4

    Inhaltsverzeichnis iii · neo-fiberlink-2 inhaltsverzeichnis sicherheitshinweise .......................................................................................... 1 einleitung ......................................................................................................... 3 lieferum...

  • Page 5

    Sicherheitshinweise neo-fiberlink-2 · 1 deutsch sicherheitshinweise bitte lesen sie die folgenden sicherheitshinweise aufmerksam durch, bevor sie das g&d-produkt in betrieb nehmen. Die hinweise helfen schäden am produkt zu ver- meiden und möglichen verletzungen vorzubeugen. Halten sie diese sicherhe...

  • Page 6

    Sicherheitshinweise 2 · neo-fiberlink-2 besondere hinweise zum umgang mit laser-technologie die geräte der neo-fiberlink-2-serie verwenden baugruppen mit laser-technolo- gie, die der laser-klasse 1 oder besser entsprechen. Sie erfüllen dabei die richtlinien gemäß en 60825-1:2014 sowie u.S. Cfr 1040....

  • Page 7

    Einleitung neo-fiberlink-2 · 3 deutsch einleitung mit einem sender- und einem empfängermodul der neo-fiberlink-serie erhöhen sie die reichweite zwischen zwei matrixswitches (catcenter neo) innerhalb des matrixsystems um bis zu 10.000 meter. Die datenübertragung zwischen beiden modulen erfolgt über z...

  • Page 8

    Lieferumfang 4 · neo-fiberlink-2 master . . Slave ..

  • Page 9

    Installation neo-fiberlink-2 · 5 deutsch installation das sender- und das empfängermodul können sie wahlweise zwischen dem master- und dem slave-matrixswitch (kaskadenstufe 1) oder den slave-matrixswitches der kaskadenstufe 2 platzieren. Anschluss des sendermoduls (neo-fiberlink-2tx) platzieren sie ...

  • Page 10

    Inbetriebnahme 6 · neo-fiberlink-2 anschluss des empfängermoduls (neo-fiberlink-2rx) platzieren sie das empfängermodul in der nähe des master-matrixswitches. Transmission – tx: stecken sie den lc-stecker des als zubehör erhältlichen glasfa- serkabels ein. Das andere ende des kabels ist mit der schni...

  • Page 11

    Statusanzeigen neo-fiberlink-2 · 7 deutsch statusanzeigen das sender- und das empfängermodul sind mit verschiedenen leds ausgestattet. Die leds an den frontseiten geben ihnen die möglichkeit den betriebsstatus der module zu kontrollieren. An den transmission-schnittstellen an den rückseiten der modu...

  • Page 12

    Statusanzeigen 8 · neo-fiberlink-2 rückseite bereich led status bedeutung trans. 1 cat gelb an bildsignal wird übertragen. Aus es wird kein bildsignal übertragen. Grün an funktionierende datenverbindungen zwischen sender- und empfängermodul. Master- und slave- matrixswitch sind angeschlossen. Blinkt...

  • Page 13

    Statusanzeigen neo-fiberlink-2 · 9 deutsch empfängermodul (neo-fiberlink-2rx) frontseite bereich led status bedeutung power red. An das optionale netzteil ist angeschlossen und liefert die erforderliche spannung. Aus das optionale netzteil ist nicht angeschlossen oder die verbindung mit dem stromnet...

  • Page 14

    Statusanzeigen 10 · neo-fiberlink-2 rückseite bereich led status bedeutung trans. 1 cat gelb an bildsignal wird übertragen. Aus es wird kein bildsignal übertragen. Grün an funktionierende datenverbindungen zwischen sender- und empfängermodul. Master- und slave- matrixswitch sind angeschlossen. Blink...

  • Page 15

    Technische daten neo-fiberlink-2 · 11 deutsch technische daten allgemeine eigenschaften der neo-fiberlink-serie video auflösung @ 60 hz: max. 1920 × 1200 bildpunkte videobandbreite: 180 mhz vertikalfrequenz: 50 hz bis 180 hz horizontalfrequenz: 30 khz bis 130 khz audio auflösung: 24 bit abtastrate: ...

  • Page 16

    I · neo-fiberlink-2 about this manual this manual has been carefully compiled and examined to the state-of-the-art. G&d neither explicitly nor implicitly takes guarantee or responsibility for the qual- ity, efficiency and marketability of the product when used for a certain purpose that differs from...

  • Page 17

    Neo-fiberlink-2 · ii english fcc statement the devices named in this manual comply with part 15 of the fcc rules. Opera- tion is subject to the following two conditions: (1) the devices may not cause harm- ful interference, and (2) the devices must accept any interference received, including interfe...

  • Page 18

    Table of contents iii · neo-fiberlink-2 table of contents safety instructions ............................................................................................ 1 introduction ...................................................................................................... 3 package c...

  • Page 19

    Safety instructions neo-fiberlink-2 · 1 english safety instructions please read the following safety instructions carefully before you start operating the g&d product. The instructions well help in avoiding damages to the product and in preventing possible injuries. Keep this manual handy for all pe...

  • Page 20

    Safety instructions 2 · neo-fiberlink-2 special advices for dealing with laser technology the devices of the neo-fiberlink-2 series use components with laser technology which comply with laser class 1 or better. They meet the requirements according to en 60825-1:2014 as well as u.S. Cfr 1040.10 and ...

  • Page 21

    Introduction neo-fiberlink-2 · 3 english introduction the transmitter and the receiver module of the neo-fiberlink series increase the range between two matrix switches (catcenter neo) within a matrix system to up to 10,000 metres. The data between the two modules is transmitted via two single- mode...

  • Page 22

    Package contents 4 · neo-fiberlink-2 master . . Slave ..

  • Page 23

    Installation neo-fiberlink-2 · 5 english installation the transmitter and receiver module can either be placed between the master and the slave matrix switch (cascade level 1) or between the slave matrix switches of the second cascade level. Connecting the transmitter module (neo-fiberlink-2tx) plac...

  • Page 24

    Start-up 6 · neo-fiberlink-2 connecting the receiver module (neo-fiberlink-2rx) place the receiver module close to the slave matrix switch. Transmission – tx: insert the lc plug of the fibre optics, which is available as acces- sory. Connect the other end of the cable to the transmission – rx interf...

  • Page 25

    Status displays neo-fiberlink-2 · 7 english status displays both the transmitter and the receiver module provide different leds. The leds on the front panel allow you to control the modules’ operating status at any time the transmission interfaces at the back panels of the modules provide additional...

  • Page 26

    Status displays 8 · neo-fiberlink-2 back panel section led status meaning trans. 1 cat yellow on the video signal is transmitted. Off no video signal is transmitted. Green on working data connection between transmitter and receiver module. Master and slave matrix switch are connected. Blinking worki...

  • Page 27

    Status displays neo-fiberlink-2 · 9 english receiver module (neo-fiberlink-2rx) front panel section led status meaning power red. On the optional power pack is connected and supplies the required voltage. Off the optional power pack is not connected, or the connection to the mains could not be estab...

  • Page 28

    Status displays 10 · neo-fiberlink-2 back panel section led status meaning trans. 1 cat yellow on the video signal is transmitted. Off no video signal is transmitted. Green on working data connection between transmitter and receiver module. Master and slave matrix switch are connected. Blinking work...

  • Page 29

    Technical data neo-fiberlink-2 · 11 english technical data general features of the neo-fiberlink series video resolution @ 60 hz: max. 1920 × 1200 pixels video bandwidth: 180 mhz vertical frequency: 50 hz to 180 hz horizontal frequency: 30 khz to 130 khz audio resolution: 24 bits refresh rate: 48 kh...

  • Page 31

    English.

  • Page 32

    Guntermann & drunck gmbh obere leimbach 9 57074 siegen germany http://www.Gdsys.De sales@gdsys.De das handbuch wird fortlaufend aktualisiert und im internet veröffentlicht. The manual is constantly updated and available on our website. Http://gdsys.De/a9100163.