  • Page 1

    Digital automatic wrist blood pressure monitor instruction manual model no.: md2220/md2222/md2223 version: 1 table of contents introduction...............................................................................1 compliance.........................................................................

  • Page 2

    Introduction thank you for purchasing the g.Lab md2220/md2222/md2223 wrist blood pressure monitor. The device is easy-to-use and good for home users and healthcare professionals. It applies non-invasive oscillometric method which can measure your blood pressure and pulse rate quickly and easily, and...

  • Page 3

    Symbols the following symbols are used in this instruction manual, or appear on the device, accessories and packaging. To assure correct use of the device, basic safety measures should always be followed including the warnings and cautions listed in this instruction manual. - 2 - symbols function / ...

  • Page 4

    Important notes do not use this device on newborns, infants, children, toddlers or persons who cannot express their intentions. The device is designed for use on adults only. Do not self-diagnosis from the measurement results and start treatment by yourself. Do not adjust medication based on the mea...

  • Page 5

    Important notes do not use the device where high frequency surgical equipment, magnetic resonance imaging (mri), computerized tomography (ct) scanner or x-ray machine is operating. Do not use the device near electromagnetic fields emission equipment such as cellular phones, microwave ovens or televi...

  • Page 6

    Important notes do not wrap the cuff around body parts other than your upper left arm. Misuse represents a risk to your health. Packaging materials are a deadly hazard for children and can cause suffocation. Remove all packaging materials immediately and keep them away from children at all times. Pr...

  • Page 7

    Device description information on the display : - 6 - heart mark irregular heartbeat indicator battery indicator pressurizing releasing air average data user 1 user 2 memory record number and data systolic pressure diastolic pressure pulse rate severe hypertension moderate hypertension mild hyperten...

  • Page 8

    Battery installation 1. Remove the battery cover. 2. Remove the used batteries and insert new batteries. Use lr03 / aaa alkaline batteries. Make sure the battery polarities (+) and (-) match the markings on the battery compartment. 3. Close the battery cover. Battery level indicator symbol on the di...

  • Page 9

    Setting date and time (a) when new batteries are installed 1. “year” will blink on the display. 2. Press m key to set the current year. 3. Press key to confirm and then "month" will start to blink. 4. Press m key to set the current month. 5. Press key to confirm and then "day" will start to blink. 6...

  • Page 10

    Before taking a measurement • before using the device, check your wrist circumference and make sure it matches the wrist cuff circumference range. • keep record of your blood pressure and pulse rate. A single measurement does not provide an accurate indication of your true blood pressure. • to ensur...

  • Page 11

    User 1 is selected user 2 is selected select user the device has a memory capability to store the measurement data for 2 users – user 1 and user 2. Every time you complete the measurement, the device automatically stores the measurement result. 1. If the device is in "off" status, press key to turn ...

  • Page 12

    Performing blood pressure measurement 1. Press key to turn on the device. 2. The cuff deflates to remove residue air before starting measurement. Releasing air indicator blinks on the display. 3. Memory record number appears on the display. 4. The cuff starts to inflate. It is normal for the cuff to...

  • Page 13

    Recall average and previous measurement data the device has a memory capability to store the measurement data for 2 users – user 1 and user 2. Every time you complete the measurement, the device automatically stores the measurement result. You can view the average reading based on the last 3 measure...

  • Page 14

    Delete measurement data there are 2 methods to delete the memory record. (a) delete one memory record 1. While you are viewing previous measurement data, select the record you want to delete. 2. Press and hold m key for about 3 seconds until "cl" and "--" appear on the display. 3. Press key to confi...

  • Page 15

    Mmhg 110 105 100 95 90 85 80 diastolic blood pressure 120 130 140 150 160 170 180 systolic blood pressure mmhg grade 3 hypertension (severe) grade 2 hypertension (moderate) grade 1 hypertension (mild) high-normal normal optimal who classification indicator the world health organization (who) has est...

  • Page 16

    About irregular heartbeat [ihb] an irregular heartbeat is defined as a heartbeat that varies by 25% from the average of all heartbeats during the blood pressure measurement. When the device detects an irregular heartbeat two or more times during the measurement, the irregular heartbeat indicator wil...

  • Page 17

    Troubleshooting - 16 - nothing appears on the display, even when the power is turned on. Batteries are drained. Replace all used batteries with new batteries. Batteries are not installed in correct polarities. Re-install the batteries with their polarities (“+” and “-“) match the polarity marking in...

  • Page 18

    Technical specification - 17 - model no. : md2220/md2222/md2223 display : lcd display measurement method : non-invasive, oscillometric method measurement range : systolic blood pressure: 50-250 mmhg diastolic blood pressure: 30-200 mmhg pulse rate : 40-180 beats/minute accuracy : pressure : +/-3 mmh...

  • Page 19

    Appendix i - 18 - the sphygmomanometer (md2220/md2222/md2223) is intended for use in the electromagnetic environment specified below. The customer of the user of the sphygmomanometer (md2220/md2222/md2223) should assure that it is used in such an environment. The sphygmomanometer ( md2220/md2222/md2...

  • Page 20

    - 19 - the sphygmomanometer (md2220/md2222/md2223) is intended for use in the electromagnetic environment specified below. The customer of the user of sphygmomanometer (md2220/md2222/md2223) should assure that it is used in such an environment. Power frequency (50hz - 60hz) magnetic field iec 61000-...

  • Page 21

    Appendix ii - 20 - the sphygmomanometer (md2220/md2222/md2223) is intended for use in the electromagnetic environment specified below. The customer of the user of sphygmomanometer (md2220/md2222/md2223) should assure that it is used in such an environment. Portable and mobile rf communications equip...

  • Page 22

    - 21 -.

  • Page 23

    - 22 - field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, am and fm radio broadcast and tv broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed rf ...

  • Page 24

    Appendix iii - 23 - recommended separation distances between portable and mobile rf communications equipment and the sphygmomanometer (md2220/md2222/md2223) the sphygmomanometer (md2220/md2222/md2223) is intended for use in an electromagnetic environment in which radiated rf disturbances are control...

  • Page 25

    - 24 -.

  • Page 26

    Appendix iv - 25 - this equipment has been tested and found to comply with the limits for a class b digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates us...

  • Page 27

    Symbol for the marking of electrical and electronics devices according to directive 2002/96/ec. The device, accessories and the packaging have to be disposed of waste correctly at the end of the usage. Please follow local ordinances or regulations for disposal. Made in china p/n: 83-m2222-cen02a-r 0...