Solaris+ System Diagram
The Solaris+ system should be connected, as shown in the diagram below.
In order to fully mount a system, please do as follows:
1)
Mount the Solaris+ Brackets in their desired location
2)
It is recommended to place the Solaris+ PSU and Solaris+ Manager close to the Brackets
in order to minimize cable distances and the potential for problems arising.
3)
Connect each bracket to the output from the Solaris+ PSU – there are 8 outputs on each
PSU. The connection is made through a cable with a Neutrik Speakon connector on each
end. These connectors are keyed to only connect one way. There is no specific sequence
in regard to connecting the Solaris+ Bracket to the output of the PSU, but care must be
paid to ensure that any maximum load is not exceeded, as follow:
Note that the top 4 outputs have a maximum capacity of 320 Watts and the bottom 4
outputs have a capacity of a further 320 Watts. Exceeding these ratings is not permitted.
In order to help you calculate the load; each Solaris sphere has a maximum current draw
of 0.5 Watts.