G.T.Power A8 Operating Manual - page 19
-
17
-
11. Various information during the process
You can inquire various information on LCD screen during charging or discharging
process. When you press
DEC button the charger shows the establishment of user
settings. And also you can monitor the voltage of individual cell by pressing
INC
button when the individual connection cable is linked to the Lithium battery being
processed.
It comes to the final voltage when the program ended.
Displayed capacity cut-off function is turn on and the
setting value of capacity.
Displayed safety timer is turn on and duration of time
in minutes.
Displayde temperature cut-off function is turn on.
The internal temperature of the charger ang the
temperature of battery being charged.
(The external temperature only will be displayed when
using the thermal probe.)
The present voltage of input DC power.
Using the individual connection cable to the battery,
you can check the individual voltage of each cell in the
battery pack. When connect the cable to the port on
the right side of the charger the program shows the
voltage of each cells for maximum 8 cells in sequence.
To utilise this feature, the battery pack must have
output connector that linked to each cells.