Gabarron ADL 2012 Installation Instructions And User Manual - page 2
Dynamic Storage Heaters
2
INSTALLATION INSTRUCTIONS AND USER GUIDE
1.- WARNING
• Please read these instructions before installing or using this appliance for the first time. The warranty of the storage
heater will not cover any damage caused by non observance of any of these instructions.
• This Guide must be kept and given to any new owner.
• This appliance should not be used by disabled persons of any kind (children included) or without notice or knowledge
of its use, except in case they are instructed and supervised by a responsible person.
• Should the heater be moved and reinstalled it is essential that the work is carried out by a fully qualified engineer.
• If during any installation the thermal insulation shows any sign of damage, it is necessary for the faulty part to be
removed and replaced by an identical part.
• The use of storage heaters is forbidden in any area where there is a presence of gases, explosives or inflammable
objects.
• Do not use this heater to dry clothes. Do not cover this heater or put objects in contact.
• The air outlet grill at the top of the heater cabinet and the air inlet at the bottom of the heater are provided to ensure the
most efficient operation of the appliance. They also protect the heater from overheating; therefore, it is essential that at
no time are they covered.
• Surfaces of this appliance could be hot. Children should be supervised to ensure they do not play with the heater.
• Check the voltage in the rating label is the same than supply.
• This heater should be switched off at the isolating switch before any repair work is carried out. This action should also
be taken during the times of the year when heat is not required.
• The installation of the heaters must be carried out in such a way that each pole can be disconnected from the supply
having a contact separation of at least 3 mm.
• The storage heater should not be installed just below an electrical socket.
• The appliance must be installed in such a way that it is impossible for anyone using a bath or shower, to touch the
controls.
• The nominal charging time of this storage heater is indicated on its rating plate and must be controlled by means of a
programmer.
• The installation must be carried out in accordance with the current electrical regulations.
• This appliance must be earthed.
• After installation a survey of the first charging cycle should be carried out to ensure that the main input thermostat
switches off. Ventilate the room during this first cycle.
• Before carrying out any work inside the appliance, the heater must be disconnected from the electricity supply.
• Never open a charged heater.
• To maintain stability, it is essential that the heater is placed on a level surface and care should be taken to avoid
irregular surfaces, such as may result from carpets or tiled surrounds partially protruding under the heater.
• The presence in the air of particles of smoke, dust and other pollutants could, in time, discolour the walls and surfaces
around the heater.
INTRODUCTION
Storage heaters are designed to take advantage of the considerable economical benefits of any restricted hour electricity
tariff.
The heaters consume electricity only during the off-peak tariff, but due to the highly efficient storage medium, give you a
truly economical 24 hours of comfort temperatures.
Model
ADL 2012
ADL 3018
ADL 4024
ADL 5030
Input
2000W
3000W
4000W
5000W
Voltage
220 – 240V~
220 – 240V~
220 – 240V~
220 – 240V~
Max. Charging time
8 h
8 h
8 h
8 h
Charge
16 kWh
24 kWh
32 kWh
40 kWh
Weight
123 kg
173 kg
225 kg
277 kg
Length
63 cm
81 cm
99 cm
117 cm
Wide
24 cm
24 cm
24 cm
24 cm
Height
66 cm
66 cm
66 cm
66 cm
Bricks
12
18
24
30