Gabarron CMX15P Installation Instructions And User Manual

Manual is about: DIGITAL MODULATING BOILERS

Summary of CMX15P

  • Page 1

    Calderas modulantes digitales para calefacciÓn y agua caliente sanitaria digital modulating boilers for heating and sanitary hot water cmx15p cmx18p instrucciones de instalaciÓn y uso installation instructions and user guide lea estas instrucciones atentamente antes de instalar o utilizar el aparato...

  • Page 2

    2 gabarrón cmxp Índice 1 importante……………………………………………………………………………….. 2 2 datos tÉcnicos..……………………………………………………………………….. 3 3 descripciÓn del cuadro de mandos…………………………………….. 4 4 instalaciÓn.............………………………………………………………………….. 5 5 puesta en servicio……………………………………………………………………5 5.1 calefacciÓn……………………...

  • Page 3

    3 2 datos tÉcnicos cmx15p cmx18p frecuencia hz 50 50 conexión 3x400v+n~ potencia limitada a 18kw; intensidad máxima a - 26.0 potencia limitada a 15kw; intensidad máxima a 21.7 26.0 potencia limitada a 13kw; intensidad máxima a 21.7 - potencia limitada a 12kw; intensidad máxima a 21.7 26.0 potencia l...

  • Page 4: Ups 25-40

    4 gabarrón cmxp dimensiones 3 descripciÓn del cuadro de mandos modelos cmx18p y cmx15p aumentar temperatura del agua de calefacción temperatura a.C.S. Y otros mensajes temperatura de calefacción y otros mensajes aumentar temperatura a.C.S. Indicador de bloqueo tecla encendido/apagado a.C.S. Tecla en...

  • Page 5

    5 4 instalaciÓn asegurarse que la tensión disponible en red, coincida con la marcada en la placa de características. La instalación eléctrica debe cumplir la legislación vigente. La sección de los conductores de alimentación debe ser suficiente para la potencia nominal o la potencia a la que se haya...

  • Page 6

    6 gabarrón cmxp 5.2 agua caliente sanitaria (a.C.S.) proceder al llenado completo del depósito acumulador de 50 litros, abriendo un grifo de la instalación del a.C.S. Para sacar el aire del acumulador de agua. Una vez que el agua fluya normalmente, cerrar el grifo y conectar el a.C.S. Pulsando la te...

  • Page 7

    7 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1 2 3 4 on 1...

  • Page 8

    8 gabarrón cmxp 7 uso de la caldera 7.1 encendido / apagado cuando la caldera se conecte a la red efectuará una autocomprobación general y si detecta algún error lo mostrará en el display correspondiente de calefacción o a.C.S. Pulse la tecla para encender la caldera. Esta misma tecla apaga la calde...

  • Page 9

    9 si la consigna es superior a la temperatura actual del agua de calefacción y no está conectada el a.C.S. Se conectará la calefacción, y se encenderá un pequeño indicador rojo de consumo de resistencias de calefacción. Esto será así siempre que el termostato de ambiente lo demande. La consigna de c...

  • Page 10

    10 gabarrón cmxp 7.3.4 seguridad en calefacciÓn falta de caudal si en el display aparece el error e3 la caldera ha detectado una falta de caudal en el circuito de calefacción. Las posibles causas de este error son: - burbujas de aire en la instalación. - bomba bloqueada. - todas las válvulas termost...

  • Page 11

    11 7.4.1 ajuste de temperatura del a.C.S. Para encender el a.C.S. Pulsar la tecla . Podemos apagar esta función pulsando esta misma tecla (el display mostrará solamente un pequeño punto rojo). Con el a.C.S. Encendida el display mostrará la temperatura actual del depósito de acumulación de a.C.S. La ...

  • Page 12

    12 gabarrón cmxp 8 mantenimiento las calderas eléctricas gabarrón no necesitan ningún mantenimiento especial, limitándose este a las siguientes comprobaciones: -comprobar la presión que marca el hidrómetro frecuentemente, asegurándose que en frío esté entre 1 y 1,5 bar. -no hacer funcionar nunca la ...

  • Page 13

    13 10 informaciÓn medioambiental las calderas gabarrón están fabricadas dentro de un sistema de gestión ambiental certificado. Todas las fases del proceso productivo desde su diseño se realizan teniendo en cuenta las máximas exigencias medioambientales. Por ejemplo, la selección de materiales se efe...

  • Page 14

    14 gabarrón cmxp p.

  • Page 15

    15 index 1 important……………………………………………………………………………….. 15 2 technical data……………………………………………………………………….. 16 3 description of the control panel……………………………………… 17 4 installation……………………………………………………………………………. 18 5 commisioning…………………………………………………………………………. 18 5.1 heating…………………………………………………………………….. 18 5.2 ...

  • Page 16

    16 gabarrón cmxp 2 technical data cmx15p cmx18p frequency hz 50 50 connection 3x400v+n~ output limited to 18kw; maximum intensity a - 26.0 output limited to 15kw; maximum intensity a 21.7 26.0 output limited to 13kw; maximum intensity a 21.7 - output limited to 12kw; maximum intensity a 21.7 26.0 ou...

  • Page 17: Ups 25-40

    17 dimensions and connection 3 description of the control panel models cmx18p & cmx15p a electrical connection b safety valve drain s.H.W c safety valve drain, heating d s.H.W. Outlet ½” e cold wáter input ½” f heating return ¾” g heating out ¾” working curves of the accelerator pump. P ups 25-40 (k...

  • Page 18

    18 gabarrón cmxp 4 installation ensure that the mains voltage available coincides with that shown on the rating label. The electrical installation must comply with the current regulations. The cross-section of the power conductors must be sufficient for the rated power or the power to which the boil...

  • Page 19

    19 5.2 sanitary hot water (s.H.W.) proceed to fill the 50-litre accumulator tank, opening the tap of the s.H.W. To draw out the air from the water accumulator. Once the water is flowing normally, shut off the tap and connect the s.H.W. By pushing the button. Select a resistance temperature for the s...

  • Page 20

    20 gabarrón cmxp it is possible to check the actual configuration of a boiler by pressing the button for three seconds. The heating display will show followed by the value of the return probe of the heating circuit. On pushing button the display will show followed by the value of the limited maximum...

  • Page 21

    21 7 using the boiler 7.1 turning on and off when the boiler is connected to the mains it will perform a general self-check and, if any defect is detected, it will be indicated on the heating or s.H.W. Displays. Push the button to start the boiler up. The same button will turn the boiler off when pu...

  • Page 22

    22 gabarrón cmxp this will always occur if the ambient temperature demands it. The heating setting can be varied between 8 and 85°c. The symbol h appears after the 85 value or before the 8 value. If we select this value, the heating will function in anti-freeze mode: if the temperature falls below 7...

  • Page 23

    23 7.3.4 heater safety flow failure if the error e3 appears on the display, the boiler has detected a flow failure in the heating circuit. The possible causes of this error are: - a blocked pump. - all the thermostat valves are closed and there is no circuit that permits the water return. - the circ...

  • Page 24

    24 gabarrón cmxp 7.4 sanitary hot water (s.H.W.) the cmx15 and cmx18 boilers have a mixed function of modulated heating and the preparation of sanitary hot water. The s.H.W. Function has priority over the heating and so the outputs are never added together. A 50-litre header tank lagged with cfc fre...

  • Page 25

    25 8 maintenance gabarrón electric boilers do not need any special maintenance, only the following should be checked: -check the pressure indicated by the pressure gauge frequently, ensuring that it is between 1 and 1.5 bar when cold. - never start the boiler when it is empty. - never start the boil...

  • Page 26

    26 gabarrón cmxp 10 environmental information gabarrón boilers are manufactured within a certified environmental management system. From the design stage, all the production phases are performed taking into account the most rigorous environmental requirements. For example, the selection of materials...

  • Page 27

    27 p.

  • Page 28: +34 902 19 57 14

    28 gabarrón cmxp www.Elnur.Es fabricado por: manufactured by: elnur s.A. Pol. Ind. “el nogal” villa esther, 11 28110, algete - madrid departamento de atención al cliente: customer service department: +34 902 19 57 14 como parte de la política de mejora continua, elnur s.A. Se reserva el derecho a re...