Gabarron IGB09MB-K3DNB7G Owner's Manual

Manual is about: Split Air Conditioner

Summary of IGB09MB-K3DNB7G

  • Page 1

    Air conditioner owner's manual modelo: igb09mb-k3dnb7g igb12mb-k3dnb7g igb18mc-k3dnb7g split air conditioner thank you for choosing our product. If you have lost the owner’s manual, please contact the local agent or visit www.Elnur.Es or sent email to elnur@elnur.Es for electronic version. For prope...

  • Page 3: Content

    Content operation notices precautions............................................................................................................1 parts name ............................................................................................................6 screen operation guide buttons o...

  • Page 4: Precautions

    Precautions warning do not connect air conditioner to multi-purpose socket. This appliance can be used by children aged from 8 operation and maintenance if the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard...

  • Page 5: Precautions

    Do not block air outlet or air inlet. It may cause malfunction. Remote controller may be broken. ● power cord is overheating or damaged. ● there’s abnormal sound during operation. ● circuit break trips off frequently. ● air conditioner gives off burning smell. ● indoor unit is leaking. Contact the d...

  • Page 6: Precautions

    Do install the circuit break. If not, it may cause malfunction. Of at least 3mm in all poles should be connected in fixed wiring. Magnet buckle and heating buckle function, it can protect the circuit-short and overload. Power supply circuit and circuit break. Precautions warning note the following t...

  • Page 7: Precautions

    Installation must be performed in accordance with the persons in order to avoid a hazard. Must be properly grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock. The appliance must be positioned so tha...

  • Page 8: Precautions

    The indoor unit should be installed close to the wall. Reachable after finishing installation. Far away from animals or plants.If it is unavoidable, please add the fence for safety purpose. Precautions warning place, only the qualified person can perform the work. Otherwise, it may cause personal in...

  • Page 9: Outdoor Unit

    (display content or position may be different from above graphics, please refer to actual products) outdoor unit air inlet air outlet connection wire parts name indoor unit air inlet panel aux.Button horizontal louver air outlet heating indicator temp. Indicator cooling indicator power indicator rec...

  • Page 10: Buttons On Remote Controller

    Buttons on remote controller introduction for icons on display screen 1 on/off button 2 mode button 3 +/- button 4 fan button 5 button 8 x-fan button 9 temp button 10 timer button 11 turbo button 12 sleep button 13 light button 7 clock button 6 timer on button up & down swing child lock set time tim...

  • Page 11: Note:

    ● after selecting auto mode, air conditioner will operate automatically according to ambient temperature. Set temperature can’t be adjusted and also can’t be displa- yed. Press "fan" button can adjust fan speed. Press " " button can adjust swing angle. ● after selecting cool mode, air conditioner op...

  • Page 12: Note:

    Introduction for buttons on remote controller "+" or "-" button fan button 3 4 5 ● after each pressing of "+" or "-" button, it can increase or decrease set temper- ature 1℃ . Hold "+" or "-" button, 2s later, set temperature on remote controller will change quickly. After reaching to your required ...

  • Page 13: Note:

    Clock button 7 introduction for buttons on remote controller x-fan button 8 6 after pressing this button under cooling or dry mode, remote controller displays the character of "x-fan" and x-fan function is started up. Press this button again to cancel x-fan function. The character of "x-fan" will di...

  • Page 14: Note:

    Note: ● outdoor ambient temperature display may can’t be selected for some models. When indoor unit receives " " signal, it displays indoor set temperature. ● only for the model whose indoor unit has dual-8 display. ● time setting range: 0.5-24 hours. ● time interval between two operations can’t exc...

  • Page 15: Child Lock Function

    Function introduction for combination buttons introduction for buttons on remote controller turbo button sleep button light button 11 12 13 when pressing this button under cooling or heating mode, air conditioner will enter into quick cooling or quick heating mode. The character of "turbo" is displa...

  • Page 16: Operation Guide

    Operation guide replacement of batteries in remote controller 1. Press the back side of remote controller marked the cover of battery box along the arrow direction. 2. Replace two 7# (aaa 1.5v) dry batteries, and make sure the position of "+" polar and "-" polar are correct. 3. Reinstall the cover o...

  • Page 17: Emergency Operation

    Emergency operation clean and maintenance air conditioner. When the air conditioner is turned on, it will operate under auto mode. Aux. Button panel warning: use insulated object to press the auto button if remote controller is lost or damaged, please use auxiliary button to turn on or turn off the ...

  • Page 18: Clean And Maintenance

    Clean and maintenance 1 2 3 4 open panel pull out the panel to a certain ● use dust catcher or water to the water (below 45℃ ) to clean it, and then put it in a shady and cool place to dry. Panel cover tightly. Operation environment, clean frequency can be increased. Warning 15.

  • Page 19: Clean And Maintenance

    Clean and maintenance 1. Check whether air inlets and air outlets are blocked. 2. Check whether circuit break, plug and socket are in good condition. 4. Check whether mounting bracket for outdoor unit is damaged or corroded. If yes, please contact dealer. 5. Check whether drainage pipe is damaged. 1...

  • Page 20: Malfunction Analysis

    Malfunction analysis general phenomenon analysis please check below items before asking for maintenance. If the malfunction still can’t be eliminated, please contact local dealer or qualified professionals. Phenomenon check items solution indoor unit can’t receive remote controller’s signal or remot...

  • Page 21: Malfunction Analysis

    Malfunction analysis ● power failure? ● is plug loose? ● circuit break trips off or fuse is burnt out? ● wiring has malfunction? ● unit has restarted immediately after stopping operation? ● whether the function setting for remote controller is correct? ● reset the function. ● wait for 3min, and then...

  • Page 22: Malfunction Analysis

    Phenomenon check items solution odours are emitted ● whether there’s odour source, such as furniture and cigarette, etc. ● eliminate the odour source. ● clean the filter. Air conditio- ner operates abnormally ● whether there’s interference, such as thunder, wireless devices, etc. ● disconnect power,...

  • Page 23: Malfunction Analysis

    Malfunction analysis error code ● when air conditioner status is abnormal, temperature indictor on indoor unit will ation of error code. Indoor display error code above indicator diagram is only for reference. Please refer to actual product for the actual indicator and position. ■ when below phenome...

  • Page 24

    Installation dimension diagram drainage pipe at least 250cm at least 15cm at least 50cm at least 50cm at least 30cm at least 300cm at least 200cm space to the obstruction space to the obstruction space to the obstruction sp ac e to th e cei lin g space to the obstruction space to the obstruction at ...

  • Page 25: Tools For Installation

    1. There should be no obstruction near air inlet and air outlet. 2. Select a location where the condensat- ion water can be dispersed easily and won't affect other people. 3. Select a location which is convenient to connect the outdoor unit and near the power socket. 4. Select a location which is ou...

  • Page 26: Safety Precaution

    Requirements for electric connection safety precaution grounding requirement 1. Must follow the electric safety regulations when installing the unit. Circuit break. 3. Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction...

  • Page 27: Installation of Indoor Unit

    Installation of indoor unit step one: choosing installation location step two: install wall-mounting frame rm it with the client. 1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the plastic expansion particles in the holes. 3. Fix the wall-mounting frame on the wal...

  • Page 28: Step Four: Outlet Pipe

    1. Aim the pipe joint at the corresponding bellmouth. 2. Pretightening the union nut with hand. 3. Adjust the torque force by referring to the following sheet. Place the open-end wrench on the pipe joint and place the torque wrench on the union nut. Tighten the union nut with torque wrench. 2. When ...

  • Page 29: Step Six: Install Drain Hose

    4. Wrap the indoor pipe and joint of con- nection pipe with insulating pipe, and then wrap it with tape. Step six: install drain hose installation of indoor unit torque wrench open-end wrench indoor pipe pipe union nut hex nut diameter tightening torque (n.M) Φ 6 Φ 9.52 Φ 12 Φ 16 Φ 19 30~40 45~55 60...

  • Page 30: Installation of Indoor Unit

    N(1) 2 3 blue brown black yellow- green outdoor unit connection 2. Make the power connection wire go through the cable-cross hole at the back of indoor unit and then pull it out from the front side. 4. Put wiring cover back and then tighten the screw. 5. Close the panel. Installation of indoor unit ...

  • Page 31: Installation of Indoor Unit

    Installation of indoor unit step eight: bind up pipe 1. Bind up the connection pipe, power cord and drain hose with the band. Indoor unit gas pipe indoor and outdoor power cord liquid pipe drain hose band 2. Reserve a certain length of drain hose and power cord for installation when binding them. Wh...

  • Page 32: Installation of Outdoor Unit

    Installation of outdoor unit (select it according to the actual installation situation) 1. Select installation location according to the house structure. 2. Fix the support of outdoor unit on the selected location with expansion screws. At least 3cm above the floor note: installing the outdoor unit....

  • Page 33

    Installation of outdoor unit step four: connect indoor and outdoor pipes 1. Remove the screw on the right han- dle of outdoor unit and then remove the handle. 2. Remove the screw cap of valve and aim the pipe joint at the bellmouth of pipe. 3. Pretightening the union nut with hand. 4. Tighten the un...

  • Page 34: Step Six: Neaten The Pipes

    Step six: neaten the pipes 1. The pipes should be placed along the wall, bent reasonably and hidden possibly. Min. Semidiameter of bending the pipe is 10cm. 2. If the outdoor unit is higher than the wall hole, you must set a u-shaped curve in the pipe before pipe goes into the room, in order to prev...

  • Page 35: Vacuum Pumping

    Vacuum pumping leakage detection 1. Remove the valve caps on the liquid valve and gas valve and the nut of refri- gerant charging vent. 2. Connect the charging hose of piezometer to the refri- gerant charging vent of gas valve and then connect the other charging hose to the vacuum pump. 3. Open the ...

  • Page 36: Check After Installation

    Check after installation test operation ● check according to the following requirement after finishing installation. Items to be checked possible malfunction has the unit been installed firmly? The unit may drop, shake or emit noise. Have you done the refrigerant leakage test? It may cause insuffici...

  • Page 37

    1. Standard length of connection pipe ● 5m, 7.5m, 8m. 4. The additional refrigerant oil and refrigerant charging required after prolonging connection pipe ● after the length of connection pipe is prolonged for 10m at the basis of standard length, you should add 5ml of refrigerant oil for each additi...

  • Page 38

    Additional refrigerant charging amount for r22, r407c, r410a and r134a diameter of connection pipe liquid pipe(mm) gas pipe(mm) Φ6 Φ6 or Φ9.52 Φ12 Φ16 Φ19 Φ22.2 Φ9.52 or Φ12 Φ16 or Φ19 Φ19 or Φ22.2 Φ25.4 or Φ31.8 _ _ cooling only(g/m) cooling and heating(g/m) 15 15 30 60 250 250 350 350 120 120 50 2...

  • Page 39: Pipe Expanding Method

    Pipe expanding method note: improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps: a: cut the pipe ● confirm the pipe length according to the distance of indoor unit and outdoor unit. ● cut the required pipe with pipe cutter. Pipe p...

  • Page 40