Gabarron MATTIRA MAS15 Installation Instructions And User Manual

Manual is about: DIGITAL MODULATING ELECTRIC BOILERS

Summary of MATTIRA MAS15

  • Page 1

    4 3 2 1 0 instrucciones de instalaciÓn y uso installation instructions and user guide mattira calderas elÉctricas modulantes digitales digital modulating electric boilers para calefacciÓn / for central heating mas18 mas15 por favor, lea estas instrucciones atentamente antes de instalar o utilizar el...

  • Page 2

    2 indice 1 importante 3 2 seguridad 3 3 introducciÓn 3 3.1 diseÑo y funcionamiento 3 3.2 principales componentes 3 3.3 situaciÓn de componentes 4 3.4 dispositivos de seguridad 4 4 instalaciÓn 4 4.1 requisitios generales 5 4.2 desembalaje y contenido 5 4.3 emplazamiento 5 4.4 dimensiones y conexiones...

  • Page 3

    3 1 importante las siguientes instrucciones de instalación guiarán a la persona competente durante todo el proceso de instalación. La garantía de la caldera no cubrirá cualquier daño causado por la no observancia de alguna de estas instrucciones. Este manual debe ser conservado y dado a cualquier nu...

  • Page 4

    4 3.3 situaciÓn de componentes 1 placa electrónica principal. 2 interruptor de encendido/apagado. 3 termostato de seguridad de calefacción. 4 resistencia de calefacción. 5 calderín aislado de calefacción. 6 purgador automático. 7 vaso de expansión de calefacción 6l. 8 placa electrónica de potencia. ...

  • Page 5

    5 a ida calefacción3/4" b retorno calefacción 3/4" c desagüe válvula seguridad d acometida eléctrica 760 350 30 265 80 a b c d 160 200 300 4 3 2 1 0 4.1 requisitos generales la instalación debe ser efectuada por una persona competente de acuerdo con la legislación vigente. La instalación también deb...

  • Page 6

    18 0 62 5 4.6 soporte de montaje marque en la pared los puntos de sujeción usando el soporte de montaje como plantilla según el esquema. Sujete el soporte de forma segura en la pared antes de elevar la caldera a su posición. Taladre los agujeros y fije el soporte comprobando el nivel y utilizando to...

  • Page 7

    7 vaso de expansión un vaso de expansión integrado de 6l proporciona la expansión necesaria a la instalación en condiciones normales de funcionamiento, sin embargo, una instalación con mayores volúmenes de agua puede necesitar una capacidad de expansión extra. 4.8 conducciÓn vÁlvula de seguridad la ...

  • Page 8

    8 secciones de cables de alimentación la siguiente tabla muestra las secciones mínimas recomendadas para una caldera en conexión trifásica 3x400v+n~. La siguiente tabla muestra las secciones mínimas recomendadas para una caldera en conexión monofásica 230v~. *la configuración estándar sólo admite co...

  • Page 9

    9 cableado de controles externos se recomienda que la caldera sea comandada por un control externo como un termostato de ambiente o un crono termostato programador como el gabarrón modelo ctp-10. PrecauciÓn: la conexión de este control debe ser libre de voltaje y conectada a los terminales indicados...

  • Page 10

    10 tipo de caldera. Para las calderas mas18 y mas15 el valor de este parámetro es 0. Modelo. 18 corresponde al modelo mas18, 15 corresponde al modelo mas15. Limitación de la potencia máxima. El modelo mas18 puede ser limitado a 18 - 15 -12 - 9 - 6 - 3 kw. El modelo mas15 puede ser limitado a 15 - 13...

  • Page 11

    11 precauciÓn: es esencial comprobar la potencia con una pinza amperimétrica. LimitaciÓn de potencia en modelo mas18 conexiÓn trifÁsica 3x400v~+n conexiÓn 230v~ limitaciÓn de potencia en modelo mas15 conexiÓn trifÁsica 3x400v~+n conexiÓn 230v~ *la configuración estándar sólo admite conexión monofÁsi...

  • Page 12

    12 5.4 calefacciÓn, llenado inicial asegúrese de que las llaves de corte estén abiertas. Localice el purgador automático en la parte superior de la caldera y afloje el pequeño tapón. Cierre los purgadores manuales de la instalación. Tenga cuidado de no salpicar ninguno de los componentes eléctricos....

  • Page 13

    13 6 instrucciones de uso de la caldera 6.1 encendido inicial precauciÓn:la potencia mÁxima limitada debe ser ajustada antes del encendido inicial. La caldera nunca debe ser encendida con la instalaciÓn de calefacciÓn o el depÓsito de acs vacÍos. Pueden ocurrir daÑos. Cuando la caldera se conecta po...

  • Page 14

    14 cuando la función calefacción esté encendida el display mostrará la temperatura del agua de calefacción. El ajuste de la temperatura de la calefacción puede ser modificado pulsando la tecla o la tecla y usando estas mismas teclas variando el valor que aparece en el display. El nuevo ajuste será a...

  • Page 15

    15 6.6 modulaciÓn en calefacciÓn la gestión electrónica de la caldera modulará automáticamente la potencia de la calefacción para adecuarla a la demanda y ahorrar energía. Esta función trabaja con la caldera “aprendiendo” y anticipando el tiempo necesario para alcanzar el nivel de temperatura del co...

  • Page 16

    16 es posible modificar temporalmente la consigna calculada en este modo de regulación automático. Si quisiéramos, por ejemplo, utilizar la caldera al máximo durante unas horas aun estando en modo de regulación automático procederíamos de la siguiente manera: al pulsar la tecla o la tecla menos en e...

  • Page 17

    17 7 problemas y soluciones 7.1 posibles fallos y soluciones problema posible causa solución la caldera no se enciende no llega corriente a la caldera. Comprobar suministro eléctrico. Interruptor general apagado. Comprobar interruptor encendido / apagado está encendido (ver 6.1). Sobrecalentamiento ...

  • Page 18

    18 7.2 sobrecalentamiento y rearme sobrecalentamiento en la calefacción. Si la caldera detecta una condición de sobrecalentamiento de 100ºc (80ºc si está adaptada a suelo radiante) en el circuito de calefacción un termostato limitador de seguridad funcionará y apagará la caldera y todas sus funcione...

  • Page 19

    19 8 lista de principales recambios 9 mantenimiento las calderas eléctricas gabarrón no necesitan ningún mantenimiento especial para una prolongada vida útil sin problemas, sin embargo, los siguientes puntos deberían observarse. - compruebe y mantenga la presión de la instalación de calefacción entr...

  • Page 20

    20 11 datos tÉcnicos mas15 mas18 frecuencia hz 50 50 conexión 3x400v+n~ potencia limitada a 18kw; intensidad máxima a - 26.0 potencia limitada a 15kw; intensidad máxima a 21.7 26.0 potencia limitada a 13kw; intensidad máxima a 21.7 - potencia limitada a 12kw; intensidad máxima a 21.7 26.0 potencia l...

  • Page 21

    21 12 esquemas elÉctricos fuse tr4 tr3 tr2 tr1 tr5 tr6 calefacciÓn bomba de circulaciÓn detector de caudal termostato de ambiente sonda de ida calefacción sonda retorno calefacción ta s.Acs flux ida ret. T.Aux t.Ext ca le fa cc io n 230v~ bomba sonda temp. Exterior (opción) placa principal k1 en el ...

  • Page 22

    1 index 1 important 2 2 safety 2 3 introduction 2 3.1 design & operation 2 3.2 principle components 2 3.3 key to components 3 3.4 safety devices 3 4 installation 3 4.1 general requirements 4 4.2 unpacking & contents 4 4.3 location 4 4.4 dimensions & connections 4 4.5 clearances 4 4.6 mounting bracke...

  • Page 23

    2 1 important the following installation instructions are intended to guide the competent person throughout the entire installation process. The boiler’s guarantee does not cover any damage caused by non-observance of any of these instructions. These installation instructions and user’s guide must b...

  • Page 24

    3 3.3 key to components 1 main electronic pcb. 2 on / off switch. 3 heating safety thermal limit switch. 4 heating resistance. 5 insulated heating header tank. 6 automatic purge. 7 heating expansion vessel 6l. 8 heating power electronic pcb 9 circulation pump. 10 heating flow detector. 11 heating 3 ...

  • Page 25

    4 760 350 30 265 80 a b c d 160 200 300 4 3 2 1 0 a heating flow ¾” b heating return ¾” c safety valve drain d electrical connection 4.1 general requirements the installation should be carried out by a person certified as competent for the installation of unvented hot water systems in accordance wit...

  • Page 26

    18 0 62 5 4.6 mounting bracket mark the hole positions using the wall bracket as a template per the diagram. Fit bracket securely onto wall before lifting appliance into position. Drill the holes and fit the bracket ensuring it is level using suitable high strength screws, with appropriate plugs or ...

  • Page 27

    6 system expansion an integral 6 l expansion vessel provides for expansion of the heated system water under normal conditions however a system with larger volumes of water may require extra expansion capacity to be provided. 4.8 safety valve connections the 3 bar pressure relief valve may discharge ...

  • Page 28

    7 electrical supply sizing the following table shows the specification for a boiler installed on three phase single phase 3x400v+n~. The following table shows the specification for a boiler installed on single phase 230v~ supply. * the standard configuration of the boiler only allows a maximum of 12...

  • Page 29

    8 wiring external controls it is recommended that the boiler is controlled by an external control such as a time clock or room thermostat or a combined programmable room thermostat such as the gabarrónmodel ctp-10. Caution: the switching connection of this control should be volt free and connected t...

  • Page 30

    9 boiler type. For mas18 and mas15 boilers, this parameter is 0. Model. 18 corresponds to model mas18, 15 corresponds to model mas15. Boiler maximum output limit. Model mas18 can be limited to 18 - 15 - 12 - 9 - 6 - 3 kw. Model mas15 can be limited to 15 - 13 - 12 - 11 - 10 - 9 - 8 - 7 - 6 - 5 - 4 -...

  • Page 31

    10 caution: it is essential to confirm the power output with the use of a clamp meter limitation of output on models mattira system mas18 connection three-phase 3x400v~+n connection single phase 230v~ limitation of output on models mattira system mas15 connection three-phase 3x400v~+n connection sin...

  • Page 32

    11 5.4 heating system initial filling ensure both flow and return isolation valves are open. Identify the boiler automatic air release valve at the top right hand side of boiler and loosen the cap. Close any manual air vents fitted on the system. Be careful not to splash any of the electrical compon...

  • Page 33

    12 6 operating the boiler 6.1 initial switching on caution: the maximum heat output must be adjusted before switching on. The boiler should never be switched on with the heating system tank empty. Damage could occur. When the boiler is first connected it will perform a general self-check and if a fa...

  • Page 34

    13 when the heating mode is selected the display will show the temperature of the heating water. We can modify the setting of the temperature of the water by pushing either the button or the button and using the same buttons to adjust the value that flashes on the display. The modified setting will ...

  • Page 35

    14 6.6 heating modulation feature the advanced control board on the boiler will automatically modulate the heating output to the demand required to save energy. This function works by the boiler ‘learning’ and anticipating the time taken to reach the temperature level demanded by the external thermo...

  • Page 36

    15 you can temporarily override the automatically calculated set point. If, for example, you want to use the boiler to the maximum for a few hours even when automatic control mode, you would proceed as follows: when pressing the or button, the display will alternatively show the calculated set point...

  • Page 37

    16 7 troubleshooting 7.1 possible faults & solutions problem possible cause solution boiler will not start no power to boiler. Check incoming power supply. No power. Check boiler control switch is on. (see section 6.1.) heating overheat. Switch tripped. Locate switch and reset. (see section 7.2) fau...

  • Page 38

    17 7.2 overheat lock-out & re-setting central heating overheat. If the boiler detects an overheat condition of 100ºc (80ºc if adapted floor heating) in the central heating circuit a safety thermal limit switch will operate and switch the boiler off disabling all functions. The cause of the overheat ...

  • Page 39

    18 8 main components 9 maintenance & care gabarrón electric boilers do not require any special maintenance for a prolonged and trouble-free life however the following points should be observed. - check and maintain the heating system pressure between 1 & 1.5 bar when cold. Frequent re-filling of the...

  • Page 40

    19 11 technical data mas15 mas18 frequency hz 50 50 connection 3x400v+n~ output limited to 18kw; maximum intensity a - 26.0 output limited to 15kw; maximum intensity a 21.7 26.0 output limited to 13kw; maximum intensity a 21.7 - output limited to 12kw; maximum intensity a 21.7 26.0 output limited to...

  • Page 41

    20 12 wiring diagrams fuse tr4 tr3 tr2 tr1 tr5 tr6 heating circulating pump heating flow detector ambient thermostat heating flow temp. Probe heating return temp. Probe ta s.Acs flux ida ret. T.Aux t.Ext 230v~ bomba ext. Temp. Probe (optional) ca le fa cc io n tr3 tr4 tr5 tr6 tr2 tr1 r6 r5 r4 r3 r2 ...

  • Page 42

    21 notas / notes.

  • Page 43

    22 declaracion de conformidad de acuerdo con la norma iso / iec 17050-1 declaration of conformity according to the standard iso / iec 17050-1 nº 6610000 nombre del fabricante : elnur, s.A. Manufacturer’s name : dirección del fabricante : elnur, s.A. Manufacturer’s address : travesía de villa esther,...

  • Page 44

    Fabricado por / manufactured by elnur s.A. Travesía de villa esther, 11 28110 algete - madrid +34 91 628 1440 www.Elnur.Es www.Elnur-global.Com www.Elnur.Co.Uk como parte de la política de mejora continua, elnur s.A. Se reserva el derecho a realizar modificaciones técnicas sin previo aviso. As a par...