Gaggenau AH 530-120 Operating And Assembly Instructions Manual

Summary of AH 530-120

  • Page 1

    Operating and assembly instructions ah 530-190/120 ah 532-190/120 extractor hood.

  • Page 2

    1 ah 530-190 ah 530-120 ah 532-190 ah 532-120 preface 1. Important notes page 3-4 1.1 for your safety page 3 1.2 operating for the first time page 4 1.3 about use page 4 2. Features page 5 3. Operation page 6-8 4. Cleaning and care page 9-10 5. Maintenance page 11.

  • Page 3

    2 preface with your new extractor hood, working in the kitchen will be even more fun. The appliance offers you a number of advantages: – a good extraction capacity with low noise values, – a large number of control functions, – optimum illumination of the cooking surface by a dimmable halogen light....

  • Page 4

    1.1 for your safety – damaged appliances must not be operated. – the appliance must only be connected by an authorised specialist , paying attention to the relevant regulations of the power supply companies and the regional construction regulations. Also observe the assembly instructions! – connecti...

  • Page 5

    1.2 operating for the first time before operating the appliance for the first time, please pay attention to the following notes: – the appliance must be installed and connected by a specialist before it is operated for the first time. – conscientiously read through the operating and assembly instruc...

  • Page 6

    5 2. Features 1 outgoing air ducts 2 control panel 3 grease filter 4 lighting installation accessories: stainless steel-design ventilation duct: lk 530-010 for ceiling heights of 2.20 - 2.66 m lk 530-020 for ceiling heights of 2.66 - 3.15 m aluminium-design ventilation duct: lk 530-011 for ceiling h...

  • Page 7

    6 3. Operation the ah 530/532-190 is 90 cm wide, and the ah 530/532-120 is 120 cm wide. Operation of both extractor hoods is identical. After they have been pressed, all functions selection keys except 0 (“motor off”) are backlit in green. Light the lighting can be switched on or off, regardless of ...

  • Page 8

    7 the int key for the intensive level should be pressed when browning and frying in an open pan (see fig. 6). If you have switched on the hood by selecting the intensive level, it will be switched off again automatically after 5 minutes. If you press the int key while the hood is running at fan leve...

  • Page 9

    8 special functions: intensive time: you can set the intensive level running time to 3, 5 or 10 minutes by simultaneously pressing the int key and the 1, 2 or 3 key and you can store this setting (see fig. 9). When delivered, the appliance is set to five minutes, i.E. The combination of the int key ...

  • Page 10

    9 cleaning the grease filters the grease filter saturation display f flashes after an operating time of 30 hours to you indicate to you that you should clean the grease filter (see fig. 3). The grease filters can of course be cleaned at any time, even if the grease filter saturation display has not ...

  • Page 11

    Cleaning the extractor hood clean the extractor hood and the aluminium- design ventilation ducts (lk 530-011/021) with a soft cloth and mild detergent solution only. Clean the stainless-steel design ventilation ducts (lk 530-010/020) with mild detergent solution and apply stainless steel care agent ...

  • Page 12

    First disconnect the appliance from the mains before carrying out any repairs. In the event of malfunctions, first of all check the household fuses. If the power supply is in proper working order, but the appliance is nevertheless not functioning, then please contact your specialist dealer or your r...

  • Page 13

    12 6.1 technical data ah 530-190: weight: 23.5 kg dimensions: 898 x 550 mm ah 532-190: weight: 21.5 kg dimensions: 898 x 550 mm ah 530-120: weight: 27.5 kg dimensions: 1198 x 550 mm ah 532-120: weight: 25.5 kg dimensions: 1198 x 550 mm electrical connection pay attention to the rating plate data. Th...

  • Page 14

    13 flexible aluminium pipes, corrosion-protected sheet metal pipes and exhaust air pipes whose material conforms to fire b1 in accordance with din 4102 can be used. Exhaust air pipes should have a nominal diameter of 150 mm. Pay particular attention to ensuring that – the exhaust air ducts and pipes...

  • Page 15

    The following note applies to extractor hood ah 532-190 or ah 532-120 only; these models do not have an integrated fan: the extractor hood can only be used in exhaust air mode. The exhaust air is conveyed upwards through an externally attached fan via a ventilation shaft or directly into the open ai...

  • Page 16

    15 proceed as follows: – from the bottom edge of the hood, mark a center line on the wall. – with the aid of the drilling template, mark the positions of the screws on the wall (fig. 19). – pay attention to the minimum clearance of 600 mm for electric cookers and 700 mm for gas cookers. The bottom e...

  • Page 17

    – secure the hood on the wall with the four screws b (fig. 21). – establish the pipe connection. – establish the electrical connection. – stainless steel chimney only (lk 530-010/020): pull the protective film off the chimney’s trims. Note: avoid damaging the sensitive metal surfaces. – fit the top ...