Gaggenau VL 051-907 Operating And Assembly Instructions Manual

Manual is about: Automatically extendible hob ventilator

Summary of VL 051-907

  • Page 1

    Operating and assembly instructions vl 051-907 automatically extendible hob ventilator 3.

  • Page 2

    Vl 051-907 1 preface 1. Important notes page 3-4 1.1 for your safety page 3 1.2 operating for the first time page 4 1.3 about use page 4 2. Structure and operating principle page 5 2.1 structure of the appliance page 5 2.2 control panel page 5 2.3 accessories page 5 3. Operation page 6 4. Cleaning a...

  • Page 3

    2 preface with your new hob ventilator, working in the kitchen will be even more fun. The appliance offers you the following advantages: – kitchen vapours and fats are sucked away directly where they arise. – the advantages of a hob ventilator are combined with those of a single-point extractor. To ...

  • Page 4

    3 1. Important notes 1.1 for your safety damaged appliances must not be operated. The appliance must only be connected by an authorised specialist , paying attention to the relevant regulations of the power supply companies and the regional construction regulations. Also observe the assembly instruc...

  • Page 5

    4 1.2 operating for the first time 1.3 about use before operating the appliance for the first time, please pay attention to the following notes: – conscientiously read through the operating and assembly instructions before operating the appliance for the first time. – the rating plate for this appli...

  • Page 6

    5 2.1 structure of the appliance 2.2 control panel 2.3 accessories 1 grease filter 2 lid 3 swivel arm 4 tub 5 control panel 6 “height adjustment" control knob 7 grease filter pilot lamp 8 “power level" control knob with the positions 0, 1, 2, 3, after-running stage and grease filter indication you c...

  • Page 7

    Switching on – turn the “power level" control knob to the required position on the right. The boom moves automatically to the frying position, and it can then be extended continuously up to its fully extended position (cooking position) by turning the “height adjustment" knob. You can also extend th...

  • Page 8

    Caution: avoid sharp and caustic cleaning agents as well as brushes and abrasive cleaners. Clean the stainless steel tub with mild rinsing detergent and apply stainless steel care agent to the metal surfaces using a soft cloth. Only clean the switch panel with a soft cloth. Do not use any cleaning a...

  • Page 9

    Swivel arm cleaning if the swivel arm gets very dirty, it can be dis- mantled for cleaning. You can clean the swivel arm in a dishwasher at a maximum temperature of 65°c. Proceed as follows: – turn the “height adjustment" control knob to the right to extend the boom slightly. By doing so, you can de...

  • Page 10

    9 first disconnect the appliance from the mains before carrying out any repairs. In the event of malfunctions , first of all check the household fuses. If the power supply is in proper working order, but the appliance is nevertheless not functioning, then please contact your specialist dealer or you...

  • Page 11

    10 6.1 technical data rating: 260 w weight: 19 kg a fan module is needed for suction extraction. Technical modifications reserved. 6.2 important notes the appliance must only be connected by an authorised specialist . The specialist is respon- sible for perfect functioning of the appliance at its in...

  • Page 12

    6.3 electrical connection pay attention to the rating plate data. The mains connecting cable must at least correspond to the type h 05 vv-f g 0,75. After installation, plug the connecting cable plug in an accessible socket. If the plug can no longer be removed after installation, isolation of all po...

  • Page 13

    6.5 installation the hob ventilator can be installed next to one or between two built-in vario appliances. Choose the suitable connection variant (see pages 13-15) before beginning with installation. – produce the recess for the appliance. Proceed as indicated on the installation sketch and the dime...

  • Page 14

    Refer to the operating instructions of the fan module for details of how to install it. Depending on the installation situation , three variants of connection to a fan module are possible: installation situation 1 (fig. 9-11) height of the worktop ≥ 90 cm, width of the cabinet at least 60 cm, compac...

  • Page 15

    Installation situation 2 (fig. 12-14) worktop height ≥ 90 cm, variable position of the fan module – saw out the base plate in the built-in cabinet for the fan module. – place the fan module in the base cabinet. Refer to the operating instructions of the fan module for details of how to install it. –...

  • Page 16

    Installation situation 3 (fig. 15-17) worktop between 86 and 90 cm high – saw out the base plate in the built-in cabinet for the fan module. – place the fan module in the base cabinet. Refer to the operating instructions of the fan module for details of how to install it. – join the pipe connection ...

  • Page 17

    Gaggenau hausgerÄte gmbh carl-wery-str. 34 · 81739 mÜnchen germany y (0 89) 45 90-03 fax (0 89) 45 90 - 23 47 www.Gaggenau.Com.