Gaggenau VL 430 Operating And Assembly Instructions Manual

Manual is about: Hob ventilator

Summary of VL 430

  • Page 1

    Operating and assembly instructions vl 430/431 hob ventilator.

  • Page 3

    1 1. Important notes page 3-4 for your safety page 3 operating for the first time page 4 maintenance page 4 2. Features page 5 features page 5 special accessories page 5 3. Operation page 6 4. Cleaning and care page 7 5. Assembly instructions page 8-11 important notes on installation page 8 installi...

  • Page 4

    2 preface congratulations on buying your new “vario” appliance. Before switching your appliance on for the first time, we would like you to familiarize yourself with your new appliance. In this manual you will find important notes on safety and operation. These will serve to ensure your personal saf...

  • Page 5

    3 1. Important notes f or your safety do not operate the appliance if it is damaged. The appliance must only be connected by an authorised specialist, paying attention to the relevant regulations of the power supply companies and the regional construction regulations. Observe the assembly instructio...

  • Page 6

    4 operating for the first time before operating the appliance for the first time, please pay attention to the following notes: conscientiously read through the operating and assembly instructions before operating the appliance for the first time. Remove the packaging from the appliance and dispose o...

  • Page 7

    F eatures special accessories 1 v entilation flaps 2 metal grease filter 3 membrane key pad (vl 431 only) 4 clamping screw 5 suction extraction connection al 400-000 edge trim r v 050-150 bifurcated pipe for joining 2 x dn 125 into dn 150 ls 330-000 air baffle 5 2. Features 1 2 3 4 5.

  • Page 8

    Note: vl 430 can only be operated in combination with vl 431. All operator inputs apply to both hob ventilators. That is to say: if you press the key for level 1, both hob ventilators are operated at level 1. Switching on press the corresponding membrane key for the required level. The indicator lig...

  • Page 9

    7 cleaning the grease filter • switch appliance to level 1. The flaps open. • push the flaps towards the front and carefully lift them up on the rear. Then take off the flaps upwardly. • turn the two retaining hooks on the sides up, slightly push them together and remove the metal grease filter. You...

  • Page 10

    8 important notes on installation the appliance must only be connected by an authorised specialist. The specialist is responsible for perfect functioning of the appliance at its installation location. He must explain to the user how the appliance can be disconnected from the mains whenever required....

  • Page 11

    9 installing the appliance if two v ario appliances are used, the hob ventilator must be installed between the appliances. If 4-plate hobs are used, it is recommended to place two ventilators to the left and right of the hob. Owing to the high air output, an adequate supply of air is required. If yo...

  • Page 12

    10 • turn the clamping screws to the side. Insert the appliance with the control panel on the front into the cut-out and align it. Note: do not stick the appliance onto the worktop with silicone. • turn the clamping screws under the countertop and tighten them evenly. Do not tighten the clamping scr...

  • Page 13

    Electrical connection pay attention to the rating plate data. Observe the connecting scheme when connecting the hob ventilator and the fan module. 9000029649 en 12.04 eb 11 connectors vl 431 connecting cable to gb connecting cable to vl 430

  • Page 16

    Gaggenau hausgerÄte gmbh carl-wery-str. 34 · d - 81739 mÜnchen y ( 0 89) 45 90 - 03 fax (0 89) 45 90 - 23 47 www.Gaggenau.Com.