GAI-Tronics 10959-207 User Manual

Other manuals for 10959-207: Operation, Installation And Service Manual
Manual is about: Rack-Mount Audio Messenger Interfaces

Summary of 10959-207

  • Page 1

    Pub.: 42004-404e gai-tronics corporation 400 e. Wyomissing ave. Mohnton, pa 19540 usa 610-777-1374 „ 800-492-1212 „ fax: 610-796-5954 v isit www . Gai - tronics . Com for product literature and manuals g a i - t r o n i c s ® c o r p o r a t i o n a h u b b e l l c o m p a n y model 10959-207 and -2...

  • Page 2

    Table of contents pub.: 42004-404e m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces f:\standard ioms - current release\42004 instr. Manuals\42004-404e.Doc 03/11 date set up..............................................................................................................

  • Page 3: Model 10959-207 and -208

    P ub . 42004-404e gai-tronics corporation 400 e. Wyomissing ave. Mohnton, pa 19540 usa 610-777-1374 „ 800-492-1212 „ fax: 610-796-5954 v isit www . Gai - tronics . Com for product literature and manuals g a i - t r o n i c s ® c o r p o r a t i o n a h u b b e l l c o m p a n y model 10959-207 and -...

  • Page 4

    Pub. 42004-404e m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 2 of 19 f:\standard ioms - current release\42004 instr. Manuals\42004-404e.Doc 03/11 options • telephone access • integration to page/party ® systems • up to 40 general inputs and 40 general outputs • routabi...

  • Page 5

    Pub. 42004-404e m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 3 of 19 f:\standard ioms - current release\42004 instr. Manuals\42004-404e.Doc 03/11 optional telephone operation the telephone interface has multiple operational modes. The appropriate mode is configurable b...

  • Page 6

    Pub. 42004-404e m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 4 of 19 f:\standard ioms - current release\42004 instr. Manuals\42004-404e.Doc 03/11 optional advance operation the page/party ® operation allows for the ami to play messages/alarms and connect phone calls to...

  • Page 7: Installation

    Pub. 42004-404e m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 5 of 19 f:\standard ioms - current release\42004 instr. Manuals\42004-404e.Doc 03/11 installation power disconnect. The power cord is the main power disconnect for all units. Disjontion de l’alimentation. Le ...

  • Page 8

    Pub. 42004-404e m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 6 of 19 f:\standard ioms - current release\42004 instr. Manuals\42004-404e.Doc 03/11 field wiring figure 3. Back of rack with connections labeled digital outputs the terminal block labeled digital outputs pro...

  • Page 9

    Pub. 42004-404e m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 7 of 19 f:\standard ioms - current release\42004 instr. Manuals\42004-404e.Doc 03/11 table 2. Digital output assignment metalwork label internal terminal pin-out function or act description gnd tb1-1 ground o...

  • Page 10

    Pub. 42004-404e m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 8 of 19 f:\standard ioms - current release\42004 instr. Manuals\42004-404e.Doc 03/11 audio the terminal block labeled audio provides connections for audio inputs and outputs, and for local rs-485 data connect...

  • Page 11

    Pub. 42004-404e m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 9 of 19 f:\standard ioms - current release\42004 instr. Manuals\42004-404e.Doc 03/11 power the terminal block labeled class 2 12 –24 vdc provides power connection for the ami. Table 6. Power assignment metalw...

  • Page 12: Settings and Adjustments

    Pub. 42004-404e m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 10 of 19 f:\standard ioms - current release\42004 instr. Manuals\42004-404e.Doc 03/11 settings and adjustments opening the unit if installed in a card rack, remove the four 10-32 × ¾-inch screws holding the u...

  • Page 13

    Pub. 42004-404e m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 11 of 19 f:\standard ioms - current release\42004 instr. Manuals\42004-404e.Doc 03/11 jumper settings 600-ohm line termination the unit can terminate the 600-ohm line with 600 ohm for impedance matching. P5 o...

  • Page 14

    Pub. 42004-404e m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 12 of 19 f:\standard ioms - current release\42004 instr. Manuals\42004-404e.Doc 03/11 date and time set up date set up push buttons on the front of the unit allows for date set up. Complete the following proc...

  • Page 15: Operation

    Pub. 42004-404e m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 13 of 19 f:\standard ioms - current release\42004 instr. Manuals\42004-404e.Doc 03/11 operation once the compactflash ® is programmed and installed into the unit, the unit operates based on system inputs and ...

  • Page 16

    Pub. 42004-404e m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 14 of 19 f:\standard ioms - current release\42004 instr. Manuals\42004-404e.Doc 03/11 lcd display during operation the lcd uses various symbols to indicate ami activity. • the vu meter indicates the volume of...

  • Page 17

    Pub. 42004-404e m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 15 of 19 f:\standard ioms - current release\42004 instr. Manuals\42004-404e.Doc 03/11 push-button operation the front panel push buttons allow for various control features including, play a message, stop a me...

  • Page 18

    Pub. 42004-404e m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 16 of 19 f:\standard ioms - current release\42004 instr. Manuals\42004-404e.Doc 03/11 ami configuration tool (act) overview the audio messenger interface configuration tool (act) software is used to define an...

  • Page 19

    Pub. 42004-404e m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 17 of 19 f:\standard ioms - current release\42004 instr. Manuals\42004-404e.Doc 03/11 output each output circuit must be enabled or disabled. If enabled, it must be programmed with several parameters such as:...

  • Page 20: Specifications

    Pub. 42004-404e m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 18 of 19 f:\standard ioms - current release\42004 instr. Manuals\42004-404e.Doc 03/11 compactflash ® the compactflash ® memory card stores the system configuration, speech messages, and alarm tones. Formattin...

  • Page 21

    Pub. 42004-404e m odel 10959-207 and -208 r ack -m ount a udio m essenger i nterfaces p age 19 of 19 f:\standard ioms - current release\42004 instr. Manuals\42004-404e.Doc 03/11 communications advance.......................................................................................................

  • Page 22: Warranty

    (rev. 10/06) warranty equipment. Gai-tronics warrants for a period of one (1) year from the date of shipment, that any gai-tronics equipment supplied hereunder shall be free of defects in material and workmanship, shall comply with the then-current product specifications and product literature, and ...