Pub.: 42004-071f gai-tronics corporation p.O. Box 1060, reading, pa 19607-1060 usa 610-777-1374 n 800-492-1212 n fax: 610-775-6540 v isit www . Gai - tronics . Com for product literature and manuals g a i - t r o n i c s ® c o r p o r a t i o n a h u b b e l l c o m p a n y model ti984 telephone int...
42004-071f gai-tronics corporation p.O. Box 1060, reading, pa 19607-1060 usa 610-777-1374 n 800-492-1212 n fax: 610-775-6540 v isit www . Gai - tronics . Com for product literature and manuals model ti984 telephone interface confidentiality notice this manual is provided solely as an operation, inst...
P age 2 of 14 m odel ti984 t elephone i nterface 42004-071f f:\standard ioms - current release\42004 instr. Manuals\42004-071f.Doc 05/03 warning this equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause i...
P age 3 of 14 m odel ti984 t elephone i nterface 42004-071f f:\standard ioms - current release\42004 instr. Manuals\42004-071f.Doc 05/03 recommendations: • remove the printed circuit board assemblies (pcbas) until installation of the conduit is complete. • use 1.25-inch conduit hub assemblies becaus...
P age 4 of 14 m odel ti984 t elephone i nterface 42004-071f f:\standard ioms - current release\42004 instr. Manuals\42004-071f.Doc 05/03 figure 2. Termination area telephone line connections the ti984 should be connected to the central office (co) rj11c jack from the telephone company or to a pbx wi...
P age 5 of 14 m odel ti984 t elephone i nterface 42004-071f f:\standard ioms - current release\42004 instr. Manuals\42004-071f.Doc 05/03 if using a dc source, either a battery and/or a ul-approved power supply/battery charger should be used. The power supply must be capable of providing at least 1.4...
P age 6 of 14 m odel ti984 t elephone i nterface 42004-071f f:\standard ioms - current release\42004 instr. Manuals\42004-071f.Doc 05/03 terminals 7 and 8 are used for the remote a ccess switch; terminals 9 and 10 are used for the remote r eset switch; terminals 11 and 12 are used for the remote d a...
P age 7 of 14 m odel ti984 t elephone i nterface 42004-071f f:\standard ioms - current release\42004 instr. Manuals\42004-071f.Doc 05/03 programming procedure read the following instructions to determine which parameters are to be set, and which parameters remain at the factory setting (default sett...
P age 8 of 14 m odel ti984 t elephone i nterface 42004-071f f:\standard ioms - current release\42004 instr. Manuals\42004-071f.Doc 05/03 programming example: night mode dial sequence description #*92 puts the unit into program mode #31 selects ring access incoming mode #40 sets incoming rings to 1 #...
P age 9 of 14 m odel ti984 t elephone i nterface 42004-071f f:\standard ioms - current release\42004 instr. Manuals\42004-071f.Doc 05/03 if someone calls and discovers that the designated party line is busy, they can choose the voice access method to notify the person they are trying to reach to ret...
P age 10 of 14 m odel ti984 t elephone i nterface 42004-071f f:\standard ioms - current release\42004 instr. Manuals\42004-071f.Doc 05/03 terminating calls calls may be terminated in one of three ways: • when there are no page/party ® handsets off-hook on the designated party line, the ti984 disconn...
P age 11 of 14 m odel ti984 t elephone i nterface 42004-071f f:\standard ioms - current release\42004 instr. Manuals\42004-071f.Doc 05/03 programming table function reset unit to factory codes (default) key sequence # # description (day mode) voice access method (for incoming calls) 7-second voice p...
P age 12 of 14 m odel ti984 t elephone i nterface 42004-071f f:\standard ioms - current release\42004 instr. Manuals\42004-071f.Doc 05/03 programming table *function select incoming call - selective access method key sequence # 3 2 p p m m a x y description if selected, incoming calls receive a code...
P age 13 of 14 m odel ti984 t elephone i nterface 42004-071f f:\standard ioms - current release\42004 instr. Manuals\42004-071f.Doc 05/03 adjustments the inside front cover of the ti984 contains 3 potentiometers to adjust audio levels. Use a small standard screwdriver to adjust the page line level. ...
P age 14 of 14 m odel ti984 t elephone i nterface 42004-071f f:\standard ioms - current release\42004 instr. Manuals\42004-071f.Doc 05/03 specifications fcc registration number ..................................................................................... Adg9zp-16816-vh-e ringer equivalency ...
(rev. 1/97) warranty equipment. Gai-tronics warrants for a period of one (1) year from the date of shipment, that any gai-tronics equipment supplied hereunder shall be free of defects in material and workmanship, shall comply with the then-current product specifications and product literature, and i...