Gainsborough 10.5 cse Installation Manual

Manual is about: E LECTRIC SHOWER

Summary of 10.5 cse

  • Page 1

    E l e c t r i c s h o w e r i n s ta l l at i o n g u i d e register your shower today to activate your free guarantee call now on 0800 408 4864 quoting gagx771b can we help you? 01959 560760 g b h 0 0 6 is su e 2 . P le a se le a ve w it h u se r.

  • Page 3: Contents

    3 contents important information 3 - safety information 3 - connections 3 - isolating valves 3 - siting 3 - pressures 3 - pressure relief device 4 product overview 4 components 5 pipework installation 6 electrical installation 7 - mains voltage connection 8 - electrical rating 9 - wiring installatio...

  • Page 4

    4 this installation and user guide is designed to ensure the safety of the installer and user and the operation/reliability of the product. Failure to observe these may cause a hazard, damage the product and invalidate your guarantee. Safety information this product must be installed by a competent ...

  • Page 5

    Pressure relief device (prd) to meet european standards, the shower unit features an integral pressure relief device (prd). The prd provides a degree of shower unit protection should an excessive build up of pressure occur within the shower. Do not operate the shower with a damaged or kinked hose or...

  • Page 6

    6 1 carefully remove the badge and loosen the fixing screw. Carefully lift the casing up and away from the engine assembly. 2 tape the template provided onto the finished wall surface in the desired position and mark the three fixing points. Drill and prepare the fixing holes using appropriate fixin...

  • Page 7: Electrical Installation

    7 5 turn on the water supply to the shower unit and check for leaks up stream of the shower unit. 4 fit the back plate assembly onto the water supply connection fix to the wall using appropriate screws (not supplied). Prior to fixing the shower unit, ensure pipe end is clean and slightly lubricated ...

  • Page 8: Mains Voltage Connection

    8 zone 0 zone 0 zone 2 zone 2 zone 2 zone 2 zone 1 zone 1 zone 3 zone 3 zone 2 zone 1 zone 1 zone 2 zone 2 zone 2 switch must be outside zone 2 2.25m 2.25m 0.6m 0.6m 0.6m 0.6m switch must be outside zone 2 ! Mains voltage connection ! Please refer to the typical system diagram shown below. The follo...

  • Page 9: Electrical Rating

    9 2 before making any connections within the installation make sure that no terminal is live. If in doubt, switch off the whole installation at the consumer unit or switch fuse (where fitted). 3 the shower unit must be connected to its own independent electrical circuit. It must not be connected to ...

  • Page 10: Wiring Installation

    Notes:- 1. Cable selection is dependant on de-rating factors detailed in the notes below 2. In certain installations the combination of low voltage and extended cable lengths may result in loss of power and a consequential reduction in flow rates. 3. Above cable sizes are the minimum acceptable size...

  • Page 11: Earth Bonding

    11 1 when the pipe work and electrical connections have been completed the front cover can then be prepared to be fitted prior to beginning the commissioning procedure. 2 where a top or bottom entry supply configuration has been used, remove the relevant pipe work and cable entry point from the requ...

  • Page 12

    12 without fitting the shower head or cover, connect the hose to the shower outlet to allow the water to discharge safely to waste. Ensure that the hose is straight and not kinked or bent (due to packaging). 2 ensuring the electric supply remains isolated turn on the water supplies. Push the engine ...

  • Page 13: User Instructions

    13 8 adjust the temperature control knob to provide the desired temperature. Allow a few seconds after each adjustment for the temperature to stabilise. A cool shower can be achieved with the temperature control knob set towards the cold direction. 9 when the unit is fully commissioned please remove...

  • Page 14: Trouble Shooting Guide

    14 trouble shooting guide page 1 of 4 action turn temperature control knob anticlockwise if so, do not use. A) switch off immediately at the electrical isolation switch. B) turn off at isolation valve. C) contact our customer service department. Disconnect handset from hose and run the shower a) if ...

  • Page 15: Action

    15 action reduce the flow by slowly turning the temperature control knob in a clockwise direction. Check isolator switched on, and remains on. Check mcb or fuse at consumer unit. Check rcd (if fitted). Check 230/240v at shower terminal block (installer/ electrician only task).Possible wiring fault o...

  • Page 16: Action

    Action clean handset spray plate - see cleaning and maintenance section check with installer or local water authority (see important information - pressures section) check inlet requirements (see important information - pressures section), and ensure no other main water devices are being used whilst...

  • Page 17: Action

    17 action ensure the correct supplied handset is used and clean from limescale. Turn off the electrical isolating switch and service valve – contact customer service department. Ensure hose is correctly fitted and tight. Ensure pipe is fully inserted into push fit connection. Disconnect shower as sh...

  • Page 18: Cleaning & Maintenance

    18 cleaning the filter cleaning the filter should only be completed by a competent person. 1. Turn the shower electrical isolating switch off (at the consumer unit or mains fuse). 2. Isolate the water supply to the shower. 3. Carefully remove badge and loosen the fixing screw, then lift off the cove...

  • Page 20

    Gainsborough bathroom products limited customer service department the flyer’s way westerham kent tn16 1de customer helpline: 01959 560760 fax: 01959 560030 registered in england & wales registration number 05221544 www.Gainsboroughshowers.Co.Uk e-mail: enquiries@gainsboroughshowers.Co.Uk the waste ...