Wiring the DMC-3xx12
The basic wiring for a DMC-3xx12 is shown in Figure 6. The disconnect switch or circuit breaker for
AC power must be installed in a location that meets the following requirements:
•
Placed in close proximity to the equipment, within easy reach of the operator, and must not
block the installation of the controller
•
Marked as the disconnect device for the equipment
Connectors for DMC-3xx12
On Board Connector
Terminal Pins
POWER
2-pin MATE-N-LOK
MOLEX# 39-31-0020
MOLEX#44476-3112
A,B,C,D: 4-pin Motor
Power Connectors
4-pin MATE-N-LOK
MOLEX# 39-31-0040
MOLEX#44476-3112
For mating connectors see
http://www.molex.com/
Power Connector
Pin Number
Connection
1
DC Power Supply Ground
2
+VS (DC Power)
Motor Connector
1
Phase C
2
Phase B (N/C for Bushed Motors)
3
No Connect
4
Phase A