9
In the operation mode the controller automatically adjusts the boiler output depending on its load, trying to maintain the boiler as close to the set
temperature as possible. In summer, when the boiler is used for heating the household hot water only, the controller can enter the supporting mode. In this
mode the boiler operates acc. to the default supporting and cannot change them. Correct selection of these parameters is the on the user’s side because they
depend on many factors such as: boiler output, household hot water tank capacity, volume of water consumed, chimney draught, fuel quality. In the extreme
cases incorrect settings of supporting parameters may be the cause of excessive temperature increase or boiler switching off.
In order to learn about the possibilities offered by the eLider boiler controller from Elster we kindly request you to acquaint yourselves with
its detailed instruction manual.
4. Assembly
4.1. Boiler transport
The boiler with burner, feeder and fuel bin is supplied on a pallet. The boiler should be removed from the pallet acc. to the below drawing.
1. Unscrew bolts connecting the boiler with the pallet.
2. Remove the upper guard.
3. Hook on the lifting lug.
4. Lift the boiler and remove the pallet.
5. Position the boiler on the floor.
2 Zdejmij osśonń górnć
3 Zaczep hak za ucho
5 Ustaw kocioś na posadzce
Drawing 3 - Removing of boiler from transport pallet.
The boiler is supplied on the pallet in assembled condition. In order to reduce the boiler mass during transport to the boiler room it is allowed to remove the
bin and detach the feeder from the boiler. For this purpose you should:
- remove the plug from the bin opening sensor (51),
- unscrew M10 bolts connecting the bin (44) with the stokehole (40,
- remove the plugs of the blower (46) and motor (43),
- remove the feeder sensor (49),
- unscrew 4 M10 bolts from the round flange and remove the feeder tube from the boiler,
- unscrew the blower.
We kindly ask you not to unscrew the Allen’s screws fixing the position of the feeder bend!
After installing the boiler in the boiler room check aligning of setting of feeder elements. If the boiler was stored in conditions of high humidity do not start
the boiler controller until it is completely dry.
3. Controller / 4. Assembly